279 [ANNEXURE - V
27.V.— ADDITIONAL REGULATIONS TO PROVIDE FOR RAIN WATER HARVESTING IN BUILDING FROM ROOF TOP FOR STORAGE/RE-USE OR LAND BASED CATCHMENT AREA FOR RECHARGING OF GROUND WATER/STORAGE/RE-USE:
- Definitions:— (a) ―Harvesting Structure‖ means a system of structures built in the building site to collect, filter and channel the rain water from roof tops/terrace or any paved or unpaved surface within the building site and to store collected rain water for percolation or recharge or storage in underground or over ground tank and re-use in non-monsoon seasons. Harvesting Structure has broad meaning and shall include ground water recharge system for percolation of water into the ground to augment the ground water stock or/to recharge the aquifers and to avoid flooding.
(b) ―Harvesting Tank‖ means a water tight underground tank to collect and store rain water collected from roof tops/terraces or any paved or unpaved surface within the building site after screening through filter beds/mediums for re-use in non-monsoon seasons.
278 Annexure IV omitted vide Amendment Regulations, 2023.
279 Substituted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
184–
(c) ―Harvesting Reservoir‖ means a water tight open to sky reservoir to collect and store rain water collected from roof tops/terraces or any paved or unpaved surface within the building site after screening through filter beds/mediums for re-use in non-monsoon seasons.
(d) ―Permeable Trench‖ means a trench dug along the compound wall/contours filled with gravel/sand mixture for recharging the ground water with rain water collected from roof tops/terraces or any paved or unpaved surface within the building site after screening through filter beds/mediums. Permeable Trench/Pit may also include trench dug on any other appropriate spot within the building sites or recharging of the ground water.
(e) ―Recharge Well‖ means a well with filter bed structure built around existing well/ /abandoned bore well to recharge the ground water with rain water collected from roof tops/terraces or any paved or unpaved surface within the building site after screening through filter beds/mediums for re-use in non-monsoon seasons. In the case of hard rock strata, boreholes are to be made with filter arrangement to percolate water into the ground.
- Structures for Rain Water Harvesting.— (a) Rain water harvesting shall be either in form of collection of rain water from roof tops/terraces or any paved or unpaved surface within the building site through pipes/gutters into a filter bed, built around a bore well or a well for ground water recharge or through a filter bed into a underground harvesting tank or open to sky reservoir for storage and use in non-monsoon periods.
(b) Any structures proposed for installation of Rain Water Harvesting (Built underground tank or Reservoir or filter beds or bore well or permeable trench) for storage for re-use shall be permitted free of FAR, Coverage, and height rules and shall be exempt from the setback rules provided these structures shall not come in way of circulation nor interfere with the parking space as per the statute. All the storage structures created for rain water harvesting has to abide by the provisions of the design and specifications as laid down in Goa Public Health Act, 1985 for prevention of Vector Borne Diseases.
- Rain Water Harvesting System.— (a) Rain water harvesting is a system of collection, transportation and storage of rain water collected from roof tops/terraces or any paved or unpaved surface within the building site which otherwise goes as waste as run off to the natural drain/river/sea. This resource can be harvested to recharge and replenish the ground water and or is stored in harvesting tanks (Closed underground/over ground containers or built open to sky reservoir) for use after treatment in the non-monsoon periods. The on line pollution of the rainwater shall be prevented by appropriate filter beds/mediums.
(b) The harvesting tank over ground or underground shall be water tight, properly covered over and shall be constructed of RCC, GI, Steel, PVC/FRP, stone, masonry or bricks in cement mortar and shall be rendered inside with cement plaster. All building complexes especially group housing societies having a minimum discharge of 10,000 liters and above per day shall install and incorporate waste water recycling system. The recycled water shall be used for horticultural purposes only. The plans submitted to the authority shall indicate the harvesting system along with points of collection of rain water in surface reservoirs or in recharge wells or in underground tanks. All the storage structures created for rain water harvesting has to abide by the provisions of the design and specifications as laid down in Goa Public Health Act, 1985 for prevention of Vector Borne Diseases.
(c) In case of underground tank, the design shall be such so as to provide drainage of tank when necessary and water shall not be allowed to collect around the harvesting tank. The tank shall be provided with a draw off that shall be so located and fitted to prevent the entry of any animal/insects and shall have an open end to permit the overflow pipe to serve as warning pipe. All the storage structures created for rain water harvesting has to abide by the provisions of the design and specifications as laid down in Goa Public Health Act, 1985 for prevention of Vector Borne Diseases.
185–
(d) The harvesting tank shall be provided with mosquito proof lids and all the vents shall be covered with mosquito proof nylon mesh. All the collection pipes for rainwater collection system shall be thoroughly and efficiently disinfected before being put to use at the beginning of the rainy season and after every season/major repairs. All the storage structures created for rain water harvesting has to abide by the provisions of the design and specifications as laid down in Goa Public Health Act, 1985, for prevention of Vector Borne Diseases.
(e) The extent of the rain water to be collected and stored in the harvesting tank shall be proportionate to the number of users; the following design criteria are recommended:—
(i) Length/breadth: The length shall be twice the breadth.
(ii) Depth: Minimum 1.5 meters.
(iii) Air space: There should be a minimum air space of 30 centimeters between water level and the under surface of the cover.
(iv) Capacity: A capacity of 200 liters per person is recommended, the minimum capacity of harvesting tank shall be 10 cubic meters.
- Harvesting Reservoirs.— (a) The Harvesting Reservoir shall be open to sky with an out flow weir, the overflow shall be directed to existing natural drainage channel/nallah. The reservoir shall be made water tight to prevent percolation. The reservoir tank shall be fenced to prevent any misuse by stray animals/people and prevent drowning accidents.
(b) The harvesting reservoir shall not be used for any other purposes other than storage of water and re-use for irrigation/augmenting supply of water for residential/commercial/industrial use in non-monsoon periods.
- Applicability.— As per Water Resources Department, Government of Goa‘s Policy notified in 2008; only Roof Top Rain Water Harvesting i.e; rain water falling on roof tops, terrace or any paved or unpaved surface on the top of the building shall be used for storage and re-use purpose.
Roof Top Rain Water Harvesting Tank for storage and re-use purpose shall be mandatory for private buildings in case the plot area is more than 4000 m2 and having 40 units and more for secondary use such as flushing of WC, landscaping, car washing, etc. through a separate parallel line in the plot premises. Similarly, Public/Institutional Buildings/Complexes in plots above 4000 m2 and having a floor area of more than 2000 m2 and all commercial/industrial development in plots more than 4000 m2 shall provide roof top rain water harvesting tank for storage and re-use. In all other constructions, it shall be recommendatory. For availing subsidies, the provisions of rain water harvesting policy notified by the Water Resources Department shall be complied with.
However, users of this Group who incorporate Sewerage Treatment Plant (STP) or Waste Water recycling processes in their plot/premises shall be exempted from the mandatory provision of roof top rain water harvesting structures in their buildings. It is advisable that waste water available from waste water recycling process is used for secondary uses such as flushing of WC, gardening/landscaping car washing etc. through a separate parallel line in the plot/premises.
The payment of subsidy on reimbursement basis to the owners of the building on the expenditure incurred for cost of structures constructed for roof top rainwater harvesting structures shall be done by the Water Resources Department as per their Notified Policy for Roof Top Rain Water Harvesting Scheme.
Rain Water Harvesting for storage and re-use purpose shall be recommendatory for all the other buildings who are encouraged to incorporate such a system. It is advisable that water available from such storage facility is used for secondary uses such as flushing of WC, gardening/landscaping car washing etc. through a separate parallel line in the plot/premises.
However, Rain Water Harvesting for recharging of ground water especially deep aquifers shall be permitted in areas identified and designated for the purpose in the State of Goa by the Water Resource Department, Government of Goa.]
186–
ANNEXURE-VI
27.VI.
Additional Regulations to provide for Multi-Level Basement Floors in Buildings for Parking, Building Services, etc.