13.1 Minimum Ceiling Height of Rooms:
(Refer Sketch No. 4 at Chapter 28)
(a) Every habitable room in any building shall be in every part at least 2.80 meters in height from the floor to the finished underside of roof slab or ceiling, provided that in case of sloped roof the height at any point shall not be less than 2.10 meters.
(b) Wherever the height of a room in any building is more than 5.00 m, the FAR of such a room shall be calculated at twice its area. However this shall not apply to institutional/religious buildings, theatres/auditoriums/atrium/foyer, industrial buildings and alike where such requirements are for operational reasons.
(c) Height of the room for Information Technology/ITES Industry building, notwithstanding anything contained in these regulations any telematic equipment storage erection facility can have a height as required for effective functioning of that system.
213[(d) In case of industrial estates/industrial areas, the height and roofing shall be minimum as required under the Factories Act, 1948 (Central Act 63 of 1948) and the rules made thereunder.
Note: Any heights more than that as prescribed under Factories Act, 1948 and Rules made thereunder shall be permitted.]
211 Inserted vide Amendment Regulations, 2018.
213 Inserted vide Amendment Regulations, 2018.
212 Regulation 12.8 omitted vide Amendment Regulations, 2023.
98–