12.1 In order to ensure that public toilets/ wash rooms are built in various parts of the city, plot owners of the plots having an area of 3000 sq. m or more shall compulsorily construct public washroom complexes within their plots. This is in addition to the mandatory sanitary requirements. It is optional for Residential Plotted Development.
12.2 All complexes (public toilets/ wash rooms, ATM, Guard Room) should be constructed mainly in the setback area within the plots, provided they do not obstruct the firefighting path. These complexes shall follow the Provisions for Universal Designs for Persons with Disabilities, Elderly and Children.
12.3 All complexes should have single storey, with a maximum floor to ceiling height of 2.8 m and water tanks concealed with a parapet wall / jali not exceeding 1 m. in height.
12.4 All complexes should at least have 1 wash basin, 2 urinals and 1 WC each, for men and women separately, with adequate electricity, drainage, water and sewerage facilities and connected to the prevalent infrastructure network. The complex shall be well ventilated with adequate provisions for lighting. Provision of Solar power shall be made for utilization in lighting of the complex.
12.5 In such complexes, Bank ATM (up to a maximum area of 9.0 sqm only), Public washroom, Security Room/Guard Room shall be permitted in the setback area - for usage of general public, provided it does not obstruct fire vehicles movement. (refer 2.0.1.d- xiv).
12.6 Both the Public Washroom Complex and the ATM should have direct access from outside the plot i.e. direct access from the road, so as to permit usage by the general public.
12.7 Such complexes will be free of FAR and Ground Coverage and will form part of full schemes prepared by owner/ architect for approval. The complex plan will be same as adopted by Delhi Urban Art Commission.
12.8 Such complexes shall have provisions for outdoor signage, advertisements and space for public art with permission from the concerned agencies/local authorities.
12.9 Complexes shall be either be constructed and maintained by the plot owner or constructed by the plot owner and maintained by a service provider or constructed as well as maintained by a service provider.
12.10 Such complexes are not permitted to be used for purposes other than specified above.
12.11 In case of addition of such complexes in existing premise/s, shall require fire clearances and incorporation of the same in the approved layout plan by the concerned local authorities. In such cases, the approval of DUAC is not required.
Chapater 13