Level of the roads, access paths and parking areas shall be described in the plan along with specification of the materials.
11.4.1 Access Path / Walk Way
Access path from plot entry and surface parking to building entrance shall be minimum of 1.8 m wide having even surface without any steps. Slope, if any, shall not have gradient greater than 5%. Selection of floor material shall be made suitably to attract or to guide visually impaired persons (limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emits different sound to guide visually impaired persons; hereinafter referred to as “guiding floor material”. Finishes shall have a non- slip surface with a texture traversable by a wheel chair. Curbs wherever provided should blend to a common level.
11.4.2 Parking
For parking of vehicles of persons with disabilities, the following provisions shall be made:
a. Surface parking for two car spaces shall be provided near accessible entrance/lift lobby for the persons with disabilities maximum travel distance of 30.0 m. In case the access is through lift, the parking shall be located within 30 m of the lift lobby.
b. The width and length of parking bay shall be minimum 3.6 m X 5.0m. The minimum width includes the transfer area beside the car with a minimum of 1200 mm. Two accessible parking spaceswith one shared transfer area are widely used and shall have a minimum width of 6m.
c. The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.
d. Guiding floor materials shall be provided or a device, which guides visually impaired persons with audible signals, or other devices, which serves the same purpose, shall be provided.
e. Where there are two accessible parking bays adjoining each other, than 1200mm side transfer bay shall be shared by the two parking bays. The transfer zones, both on the side and the rear should have yellow or white cross – hatch road markings and connected to an accessible route 1200mm wide.
f. A minimum of one accessible designated parking space shall be provided in every parking area;
i) For up to 10 parking spaces, one designated accessible parking space shall be provided;
ii) For up to 25 parking spaces, two designated accessible parking space shall be provided;
iii) For up to 50 parking spaces, three designated accessible parking spaces shall be provided;
iv) For up to 100 parking spaces, four designated accessible parking spaces shall be provided;
v) For up to 200 parking spaces, six designated accessible parking spaces shall be provided;
vi) For over 200 parking spaces, six designated accessible parking spaces for 200 parking spaces and one for each additional 100 parking spaces shall be provided.
Note : In specialized facilities such as health care facilities, shopping areas and recreational facilities, a greater number of designated accessible parking spaces should be considered.
g. Space should be provided for passenger drop-off / alighting points for taxis, public transport and also for large vehicles such as vans, etc, as near as possible to the main accessible entrance. Vehicle drop-off areas should be a minimum of 9000 mm in length, have a minimum width of 3600 mm and be served by a kerb ramp.
h. At least one accessible route {see (e)} marked by tactile pavers leading to an accessible entrance of the building shall be provided from the alighting and boarding point of taxi stands and car park lots for people with disabilities.
11.4.3 Tactile Ground Surface Indicators (TGSI): Tactile Guiding and Warning Blocks: Tactile ground surface indicators or tactile guiding and warning tiles/blocks aid blind and vision impaired pedestrians negotiate the built environment shall be provided as per NBC norms in force.
Tactile guiding blocks indicate a correct path/ route to follow for a person with visual impairment. It is mandatory to install one/two rows of tactile guiding blocks along the entire length of the proposed accessible route. Care shall be taken to ensure that there
are no obstacles, such as trees, poles or uneven surfaces, along the route traversed by the guiding blocks. Also, there shall be clear headroom of at least 2100 mm height above the tactile guiding blocks, free of protruding objects such as overhanging tree branches and signage, along the entire length of the walk.
Tactile warning blocks indicate an approaching potential hazard or a change in direction of the walkway, and serve as a warning of the approaching danger to persons with visual impairments, preparing them to tread cautiously and expect obstacles along the travel path, traffic intersections, doorways, etc. They are used to screen off obstacles, drop-offs or other hazards, to discourage movement in an incorrect direction, and to warn of a corner or junction. Two rows of tactile warning tiles shall be installed across the entire width of the designated accessible pathway, before intersections, building entrances, level changes, obstacles such as trees, and each time the walkway changes direction.
Warning blocks shall be placed 300 mm from the beginning and end of the ramps and stairs, at landings and entrance to any door.
11.4.3.1 Places to Install TGSI
TGSI shall be installed at following places:
a) In open space to orient persons with vision impairment;
b) In front of an area where traffic is present;
c) In front of an entrance/exit to and from a ramp, staircase or multi-level crossing facility;
d) Entrances/exits at public transport terminals or boarding areas;
e) Sidewalk/footpath section of an approach road to a building; and f) From a public facility to the nearest public transport station.
11.4.3.2 Barriers and Hazards
Obstacles, such as objects or signs mounted on walls, columns or free-standing supports along the walking path shall be avoided. Unavoidable free standing posts or columns within access routes on pathways shall leave at least unobstructed walking width of 1000 mm and be clearly marked with visual indicators. Visual indicators at least 75 mm in height with a minimum visual contrast of 30 points difference in the LRV value of the colours to the background shall be placed; one at a height between 800 mm and 1000 mm above floor level, and the other between 1400 mm and 1600 mm above floor level.
Bollards, short vertical posts generally arranged in a line to guide traffic and protect from vehicle intrusions, shall have a maximum height of 1000 mm. Bollards,where installed within the access route shall have a minimum clear spacing between them of 1000 mm so as to provide clear passage width for movement of wheelchairs.
11.4.3.3 Protruding Objects
Unavoidable protruding objects shall not reduce the minimum clear width of an accessible route or maneuvering space. Protruding objects in the access route shall contrast visually with the background environment.
Objects with a height lower than 1000 mm can create a hazard for blind or partially sighted people. Permanent equipment that cannot be located outside the boundaries of a path shall be,
a) designed to be easily seen with a minimum difference in LRVs of 30 points to the background;
b) shielded to protect against impact;
c) accompanied by a feature that warns of the presence of a potential hazard and is detectable for a person using a white cane or stick;
d) the headroom along a path shall be maintained at a height of not less than 2100 mm above the surface of the path.
e) Any objects projecting more than 100 mm between 300 mm and 2100 mm above ground level into an access route shall be clearly visible and detectable with a cane.
When a projecting obstacle exists, a protective guard shall be provided at ground level, under the projecting object, such as, a kerb or fixed element at a height of 100 mm-300 mm as cane detection. Cane detection shall not be set back more than 100 mm from the face of the projecting object. Wing walls, side partitions, alcoves or recesses are solutions for projecting elements where free space under the object is needed. Winged protection shall extend continuously between 300 mm and 1000 mm above the floor and shall contrast visually with the background.