10.0 Green Buildings - See Annexure X
All buildings on various plot sizes should comply with the green norms and conform to the requirements mandatory for sanction as mentioned in this chapter.
These are not specific to any rating system and are not intended to provide a single metric indication of overall building performance. These provisions allows the practitioners to easily exercise their engineering judgment in holistically and objectively applying the underlying principles of sustainability to a development or building facility, considering its functionality and required comfort level.
10.1 Provisions and Applicability
These provisions for green buildings are applicable on all plots more than 105 sq. m in size The green building provisions on various plot sizes are indicated in the table below:
| Category of Plot Sizes (sq.m.) | Category of Plot Sizes (sq.m.) | Provisions for Green Building(as per Clause 10.2) |
| I | up to105 | Optional usage of 2 (a), 2(b). |
| II | 105 to 500 | 1(a), 2(a),2(b), 4(a) |
| 500 to 1,000 | 1(a), 1(c), 2(a),2(b), 4(a) | |
| 1,000 to 3,000 | 1(a), 1(c), 1(d), 2(a),2(b), 3(b), 4(a) | |
| III | Above 3,000 | 1(a), 1(b), 1(c), 1(d), 2(a), 2(b), 3(a), 3(b), 4(a), 4(b) |
*The schemes/ projects formulated on the basis of provisions given in Master plan/ Zonal Development Plan will require approval as indicated:
{Chapter 3 of these Bye-Laws, NBC (latest), ECBC 2007 or latest, BEE Star rating/ IGBC/ GRIHA Certification}
EIA- Environmental Impact Assessment Study Report, ECC- Environmental Clearance Certificate, MoEF – Ministry of Environment and Forest,NBC – National Building Code, ECBC – Energy Conservation Building Code, BEE – Bureau of Energy Efficiency, LEED– Leadership in Energy and Environment Design, IGBC – Indian Green Building Council, GRIHA– Green Rating for Integrated Habitat Assessment, TERI – The Energy and Resources Institute.
The prevailing provisions of the above shall be applicable. However if there are any modification in the same, the modified provisions shall become automatically applicable.
10.2 Provisions for Sanction:
(As per Annexure – X)
1.Water Conservation and Management
a. Rain Water Harvesting (by Recharge)
b. Low Water Consumption Plumbing Fixtures
c. Waste Water Recycle and Reuse
d. Reduction of hardscape
2.Solar Energy Utilization
a. Installation of Solar Photovoltaic Panels
b. Installation of Solar Assisted Water Heating Systems
3.Energy Efficiency
a. Low Energy Consumption Lighting Fixtures (Electrical Appliances – BEE Star and Energy Efficient Appliances)
b. Energy Efficiency in HVAC systems
4.Waste Management
a. Segregation of Waste
b. Organic Waste Management
10.3 In case Owner(s) of properties desire to procure green building ratings from one or more rating bodies, they may suitably incorporate any other provisions if required and additional incentive FAR as per prevalent MPD may be availed.
10.4 The installation of Solar Photovoltaic Power panels are to be installed in all types of Occupancy or Use group as mentioned in sub-clause 1.4.75 of these bye-laws. Refer Annexure X (5) for details.
10.5 Electric Vehicle Charging Infrastructure (EVCI):
The Ministry of Power, Govt. of India issued Guidelines & Standards for charging infrastructure for electric vehicles on 14.12.2018 and revised guidelines on 01.10.2019. These Guidelines & Standards are subject to modification from time to time and modified version of Central Government is to be referred.
Based on the occupancy pattern and the total parking provisions in the premises of the various building types, charging infrastructures shall be provided only for EVs (Electric Vehicles), which is currently assumed to be 20% of all ‘vehicle holding capacity’/‘parking capacity’ at the premise.
Additionally, the building premise will have to have an additional power load, equivalent to the power required for all charging points {in a Public Charging Station (PCS)} to be operated simultaneously, with a safety factor of 1.25 (refer 6. Explanatory Note on Electric Vehicle Charging Infrastructure - Annexure X).
10.5.1 Residential Buildings (plotted house)
| Building type | Plotted House |
|---|---|
| Ownership of Station | Private (Owner) |
| Connection and Metering | Domestic meter |
| Type of Charger | Slow chargers as per owner's specific requirements |
| Modes of Charging | AC (Single charging gun) |
| Norms of Provisions | Min. 1 SC and additional provisions as per the owner individual. |
Note:
* The Charging Infrastructure (CI) installed by a home owner shall be construed as a Private CI meant for self-use (non-commercial basis) as per the note at clause no D of the Explanatory Note at Annexure X- Appendix II.
10.5.2 All other buildings (including Group Housing)
Any PCS installed at Public/Private areas or building premises of any category that caters to commercial mode of charging of EVs shall be deemed as a Public Charging Station and shall have to install the minimum requirements of chargers as specified in the Guidelines & Standards of Ministry of Power, GoI. However, in order to provide sufficient charging points for the EV share in all vehicles, ratio of types of chargers is recommended in the table below -
Table 10.3: Charging Infrastructure requirements for PCS (commercial use)
For table Refer Appendix I
* For Explanatory Note on Electric Vehicle Charging Infrastructure – Refer Appendix II.