1.3.1 In these bye-laws, unless the context otherwise requires the definition given below, under clause 1.4 shall have the meaning indicated against each term.
1.3.2 The words and expressions not defined in these bye-laws shall have the same meaning or sense as in Delhi Development Act, 1957 and Master Plan for Delhi.
1.3.3 All mandatory Master Plan/ Development Control Regulations regarding use, coverage, FAR, set-backs, open spaces, height, number of stories, number of dwelling units, parking standards etc., for various categories of buildings, including modifications therein, made from time to time, shall be applicable mutatis-mutandis in the building Regulations under this clause. All amendments/ modifications made in these Regulations will automatically be included as part of these Unified Building Bye-Laws.
Note: - Extract relating to Development Control Regulations/provisions are reproduced from Master Plan for Delhi.(Chapter 5 and Annexure VI of this document).
1.3.4 All documents such as Acts, Notifications, Rules & Regulations including BIS Codes, National Building Codes, Delhi Fire Service Rules, Indian Electricity Rules, etc. referred in these Building Bye-Laws shall be applicable as amended from time to time. Thus for the current status for any legal, official purpose, the amended provisions issued by the concerned Ministry/departments(s) shall be followed.
DELHI DEVELOPMENT AUTHORITY NOTIFICATION New Delhi, the 22nd March 2016 (Unified Building Bye Laws for Delhi 2016) Chapter 1 General
S.O.1191(E):- In exercise of the powers conferred under sub-section (1)Section 57, read with Section 13 of Delhi Development Act-1957, the Delhi Development Authority, with the previous approval of the Central Government hereby make the following regulations.
The regulations earlier notified under these clauses vide Notifications No. S.O. 513, dated 26-2-1959 Gazette of India, Part-II, Section 3 (ii) dated 7-3-1959, as adopted by the Delhi Development Authority, vide Resolution No. 229 dated 1-5-1965 and the Building Bye Laws 1983, published in Extra Ordinary Part IV of Delhi Gazette, published by Government of India(Delhi Administration) vide S. O. No. 104, dated23.06.1983, in force and subsequent resolutions and amendments in Building Bye Laws 1983 were superseded by these Unified Building Bye-Laws for Delhi 2016, notified vide S.O.1191 (E ) dated 22.03.2016.
Thereafter, subsequent amendments/modifications were notified (i) vide S.O. 2479 (E) dated 21.07.2016: Amendment in Para 9.2.5 of the Unified Building Bye-Laws (UBBL) for Delhi 2016; (ii) vide S.O. 1053(E) dated 05.04.2017: Modifications in the Unified Building Bye-Laws (UBBL) for Delhi 2016; (iii) vide S.O. 1502 (E) dated 11.05.2017: Corrigendum to the Modifications in the Unified Building Bye-Laws (UBBL) for Delhi 2016;(iv)vide S.O. 859 (E) dated 28.02.2018: Modification of sub-clause 2.10 in UBBL 2016 Notified vide S.O 1053 (E) dated 5th April 2017; (v) vide S.O. 1487 (E) dated 04.04.2018: Modification in UBBL 2016 Notified vide S.O 1053 (E) dated 5th April 2017 for sub-clauses, simplification of forms/proformas and omission of submission of Bond(s)/Affidavit(s);(vi) vide S.O. 1236 (E) dated 8th March 2019 : Modifications in the Unified Building Bye-Laws (UBBL) for Delhi-2016; (vii) vide S.O. 668 (E) dated 12.02.2020 : Modifications in the Unified Building Bye-Laws (UBBL) for Delhi 2016-2020 which are compiled and incorporated and shall be the integral part of these Unified Building Bye-Laws (UBBL) for Delhi 2016 and shall be read as under:
1.0 Short Title, Extent and Commencement
These bye laws shall be called “UNIFIED BUILDING BYE LAWS FOR DELHI 2016”. These shall be applicable to the National Capital Territory of Delhi. It shall come into force on such date as the appropriate Government / Authority / Body, by notification in the Official Gazette, appoint.
1.1 Jurisdiction
These Unified Building Bye-Laws shall be applicable to the area under jurisdiction of the Delhi Development Authority and concerned local bodies.
1.2 Applicability
These building byelaws shall be applicable to all building activities and read in conjunction with specific notifications in respect of urban villages/rural villages, unauthorized regularized colonies and for special areas with regard to regularized resettlement colonies (as mentioned in Chapter 6- Regulations Notified by Delhi Development Authorities). These Bye-laws
shall be reviewed at the end of every five years. The system of implementation of these building byelaws shall be uniform in the Delhi Development Authority and all the concerned local bodies.
1.7Development and Construction
1.7.0 Except hereinafter or otherwise provided, these Bye-Laws shall apply to all development, redevelopment, erection and/or re-erection of a building etc. as well as to the design, construction of, or reconstruction and additions and alterations to a building.
1.7.1 Development permission: No person shall carry out any development or redevelopment including sub-division on any plot or land (not forming part of any approved layout plan or scheme) or cause to be done without obtaining approval from the Sanctioning Authorityfor the Layout Plan.
1.7.2 Building Permit: No person shall erect, re-erect or make addition/ alterations in any building or cause the same to be done without, first obtaining a separate building permit for each such building from the Sanctioning Authority.
1.7.3 Reconstruction: The reconstruction in whole or part of a building which has ceased to exist due to fire, natural collapse or demolition having been declared unsafe, or which is likely to be demolished by or under an order of the Sanctioning Authority as the case may be and for which the necessary certificate has been given by the Sanctioning Authority shall be allowed subject to these Bye-Laws.
1.4.1 Act: Delhi Development Act, 1957 and Act of other local bodies.
1.4.2 Air Conditioning: The process of treating air so as to control simultaneously its temperature, humidity, cleanliness and distribution to meet requirement of conditioned space.
1.4.3 Alteration: A structural change, such as an addition to the area or height, or the removal of a part of a building, or any change to the structure, such as the construction of cutting into for removal of any wall, partition, column, beam, joist floor or other support, or a change to or closing of any required means of ingress or egress or a change to the fixture or equipment.
1.4.4 Approved: Approved by the Sanctioning Authority.
1.4.5 Access: Approach to a plot or a building from a road/ street.
1.4.6 Accessory Building: A building separate from the main building on a plot and containing one or more rooms for accessory use such as servant quarters, garage, store rooms or as shall be classified by the building plan Sanctioning Authority.
1.4.7 Accessory / Ancillary Use: Any use of the premises subordinate to the principal use and incidental to the principle/ main use.
1.4.8 Amenity Space: A statutory space kept in a layout for amenities such as garbage bin, water supply installation, electricity supply installation, sewage treatment plant and includes other utilities, services and conveniences, as provided according to planning norms in layout plan.
1.4.9 Atrium/ Atria: It is a partly/ fully enclosed space with a minimum double height which is partly/ fully covered with light roofing/ R.C.C and could be constructed upon. In a building, there may be more than one atrium at ground or at any other level. Ground coverage and F.A.R to be as per MPD.
1.4.10 Sanctioning Authority: The Delhi Development Authority, New Delhi Municipal Council, South Delhi Municipal Corporation, North Delhi Municipal Corporation, East Delhi Municipal Corporation, Delhi Cantonment Board hereinafter called the ‘Sanctioning Authority’.
1.4.11 Automatic Sprinkler System: A system of water pipes fitted with sprinklers heads at suitable intervals and heights and designed to actuate automatically, control and extinguish a fire by discharge of water.
1.4.12 Automatic Fire Detection and Alarm System: Fire alarm system comprising of components for automatically detecting a fire, initiating an alarm of fire and other actions as appropriate.
Note: The system shall also include manual fire alarm call points.
1.4.13 Balcony: A horizontal cantilevered/non-cantilevered/projected slab including parapet and handrail balustrade, at any floor level including terrace to serve as a passage or sit out place with at least one side fully open, except being provided with railing or parapet wall for safety.
1.4.14 Basement or Cellar: The lower story of a building below or partly below ground level.
1.4.15 Building: Any structure for whatsoever purpose and whatsoever material constructed and every part thereof whether used as human habitation or not and includes foundation, plinth walls, floors, roofs, chimneys, and building services, fixed platforms, verandahs, balcony, or projection part of a building anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures, monuments, memorials or any contrivance of permanent nature/stability built under or over ground .
1.5.1 Part Construction: Where the part of an approved/ regularized building is demolished/ added/ altered or reconstructed, except where otherwise specifically stipulated, these Building Bye-Laws shall apply to the extent of the new work involved.
1.5.2 Change of use / Occupancy: Where use of a building is changed, except where otherwise specifically stipulated, these Building Bye-Laws shall apply to all parts of the building affected by the change; with prior permission from the Delhi Fire Services.
1.5.3 Existing approved building: Nothing in these Bye-Laws shall require the removal, alteration or abandonment, nor prevent continuance of the lawfully established use or occupancy of an existing approved building unless, in the opinion of the Sanctioning Authoritysuch a building is unsafe or constitutes a hazard to the safety of adjacent property or to the occupants of the building itself.
1.5.4 In case of any provision of these building bye-laws require further interpretation/clarification, the matter shall be referred to the Grievance Redressal Committee as constituted under clause 1.8.
1.5.5 In the bye-laws, the use of present tense includes the future tense, the masculine gender includes the feminine and the neuter, the singular number includes the plural and the plural includes the singular. The word ‘person’ includes a Corporation as an individual, writing includes printing and typing and ‘signature’ includes thumb impression made by a person who cannot write if his name is written near to such thumb impression.
1.6 Pre-Code Building Permit
Where any building permit which has been issued by the Sanctioning Authoritybefore the commencement of these Building Bye-Laws and where construction is in progress and has not been completed within the specified period from the date of such permit, the said permission shall be deemed to be sanctioned under these Bye-Laws and shall only be eligible for revalidation thereunder. Accordingly, where the validity of sanction has expired and construction has not commenced, construction shall be governed by the provisions of these Building Bye-Laws.
a. The vertical distance in the case of flat roofs is measured from the highest surrounding road level/ ground level up to the top of structural slab, excluding machine room, irrespective of location of entry level.
b. In the case of pitched roofs, up to the point where the external surface of the outer wall intersect the finished surface of the sloping roof, and in case of gable facing the road, the mid-point between the eaves level and the ridge.
c. Architectural features serving no other function except that of decoration and other building components mentioned in clause no 7.19 shall be excluded for the purpose of taking height.
d. If the building does not abut on a street, the height shall be measured from the highest level of the ground immediately adjacent to the building.
1.4.17 Building Line: The line up to which the plinth of a building adjoining a street or an extension of a street or on a future street may lawfully extend. It includes the lines prescribed in the MPD or specifically indicated in any Scheme or Layout Plan, or in these Bye-Laws.
1.4.18 Built up Area: The area covered by a building on all floors within the premise, used for activities or use, including cantilevered portion, basement, stilt/podium, utility, services, mezzanine floors (if any), other similar areas.
1.4.19 Cabin / Guard Hut: A room constructed with non-load bearing partition/partitions with minimum width of 2.0 m, provided light and ventilation standards prescribed in these bye-laws are met with or the provision of light and ventilation is to the satisfaction of the Sanctioning Authority.
1.4.20 Canopy: A cantilevered projection over an entrance.
1.4.21 Chhajja: A continuous sloping or horizontal overhang.
1.4.22 Chimney: The construction by means of which a flue is formed for the purpose of carry¬ing the products of combustion from a heat producing appliance to the open air. Chimney includes chimney stack and the flue pipe.
1.4.23 Combustible Material: A material, if it burns or adds heat to a fire when tested for combustibility in accordance with good practice.
1.4.24 Conversion: The change in nature of occupancy to another occupancy or part thereof resulting into change of use.
1.4.25 Courtyard: A space permanently opens to the sky, enclosed fully or partially by build¬ings within the building envelope.
1.4.26 Curtain Wall: Curtain wall is a system in the form of structural glazing or any other energy efficient material to improve the energy efficiency of the building which does not form the part of the structural system of the parent building.
1.4.27 Covered Area: Ground area covered immediately above the plinth level covered by the building but does not include the spaces; defined in clause 7.17.
1.4.28 Damp Proof Course: A course consisting of some appropriate waterproofing material provided to prevent penetration of dampness or moisture.
1.4.29 Detached Building: A building whose walls and roofs are independent of any other building with open spaces on all sides as specified.
1.4.30 Drain: A line of pipes including all fittings and equipment such as manholes, inspection chambers, traps, gullies and floor traps used for the drainage of a building, or a number of buildings or yards appurtenant to the buildings, within the same curtilage. Drain shall also include open channels used for conveying surface water.
1.4.31 Drainage: The removal of any liquid by a system constructed for this purpose.
1.4.32 Dwelling Unit / Tenement: An independent housing unit with separate facilities for living, cooking (maximum one kitchen)and sanitary requirement
1.4.33 Enclosed Staircase: A staircase separated by fire resistant walls from the rest of the building.
1.4.34 Entrance: A doorway or a passage way used as a means of accessing a building or a site.
1.4.35 Existing Building or Use: A building, structure or its use as sanctioned/approved/ regularized by the Sanctioning Authority, existing before the commencement of the bye-laws.
1.4.36 Exit: An exit may be a doorway; corridor; passageway(s) to an internal staircase, or external staircase, or to a verandah or terrace(s), which have access to the street, or to the roof of a building or a refuge area. An exit may also include a horizontal exit leading to an adjoining building at the same level.
a. Vertical Exit: A Vertical exit is a means of exit used for ascension or descension between two or more levels including stairways, fire towers, ramps, and fire escapes.
b. Horizontal Exit: A horizontal exit is a protected opening, through or around a fire wall a bridge connecting two buildings.
1.4.37 Outside Exit: An outside exit is an exit from the building to a public way, to an open area leading to public way or to an enclosed fire resistive passage leading to a public way.
1.4.38 Escalator: A power driven, inclined, continuous stairway used for raising or lowering passengers or goods.
1.4.39 External Wall: An outer wall of a building not being a party wall even though adjoining a wall of another building and also means a wall abutting on an interior open space of any building.
1.4.40 Fire Lift: One of the lifts specially designed for use by fire service personnel in the event of fire.
1.4.41 Fire Door: A fire-resistive door approved for openings for fire separation.
1.4.42 Fire Resisting Material: The materials or elements of construction having property to withstand the standard fire exposure.
1.4.43 Fire Resistance: The time during which it fulfils its function of contributing to the fire safety of a building when subjected to prescribed conditions of heat and load or restrain. The fire resistance test of structures shall be done in accordance with good practice.
1.4.44 Fire Separation: The distance in meters measured from other building on the site, or from other site, or from the opposite of a street or other public space to the building.
1.4.45 Fire Service Inlets: A connection provided at the base of a building for pumping up water through inbuilt firefighting arrangements by fire service pumps in accordance with the recommendation of the Delhi Fire Service.
1.4.46 Fire Tower: An enclosed staircase which can only be approached from the various floors through landings or lobbies separated from both the floor areas and the staircase by fire resisting doors and open to the outer air.
1.4.47 Floor: The lower surface in a storey on which one normally walks in a building. The general term, floor, unless otherwise specifically mentioned, shall not refer to a mezzanine floor.
Note: The sequential numbering of floor shall be determined by its relation to the determin¬ing entrance level. For floors at or wholly above ground level the lowest floor in the building with direct entrance from the road/street shall be termed as Ground floor, the other floors above ground Floor shall be numbered in sequence as Floor 1, Floor 2, etc. with number increasing upwards.
1.4.48 Floor Area Ratio (F AR): The quotient obtained by dividing the total covered area (plinth area) on all floors multiplied by 100 by the area of the plot
1.4.49 Footing: A foundation unit constructed in brick work, masonry or concrete under the base of a wall or column for the purpose of distributing the load over a large area.
1.4.50 Foundation: That part of the structure which is in direct contact with and transmitting loads to the ground.
1.4.51 Fountain: An artificially created jet or stream of water with or without structural form
1.4.52 Gallery: An intermediate floor or platform projecting from a wall of an auditorium or a hall providing extra floor area, additional seating accommodation etc.
1.4.53 Garage, Private: A building or out-house designed or used for the storage of private owned motor driven or other vehicles.
1.4.54 Garage, Public: A building or portion thereof designed other than a private garage, operated for gain, designed or used for repairing, servicing, hiring, selling or storing motor driven or other driven vehicle.
1.4.55 Gazebo: A freestanding or attached to garden wall, roofed, usually open-sided structure providing a shady resting place and ornamental features for gardens. Some gazebos in public parks are large enough to serve as bandstands or rain shelters.
1.4.56 Grievance Redressal Committee: A committee for addressing complaints/difficulties/ appeals and providing appropriate redressal in a time bound manner.
1.4.57 Ground Coverage: The portion of the building within the maximum outer surface of the structural wall/column/ slab measured at ground level shall be considered as ground coverage (excluding the mentioned limits of projection/ balcony/canopy /porch /void/shaft/cladding/ curtain wall etc.– refer 7.17.2 & 8.10)
1.4.58 Habitable Room: A room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating and kitchen if it is used as living room, but not including bathrooms, water closet compartments, laundries serving and storage pantries, corridors, cellars, attics and spaces that are not used frequently or during extended periods.
1.4.59 Helipad:A prepared area designated and used for takeoff and landing of helicopter.
1.4.60 High Rise:Any buildings of 15m and above height shall be considered as high rise building.
1.4.61 Jhamp: A downward, vertical or sloping projection hanging below any horizontal projection like balcony, canopy, verandahs, passage etc., to provide protection from direct sun and rain.
1.4.62 Jhot: Strip of land permanently left open for drainage purposes not to be used as an access way and is not a street or be included as a part of setbacks.
1.4.63 Kiosk: A booth operating for selling small consumables such as newspapers, magazines, street maps, confectionary, tea, coffee etc.
1.4.64 Ledge or Tand: A shelf-like projection supported in any manner whatsoever except by means of vertical supports within a room itself but not having projection wider than 0.75 m and at a minimum clear height of 2.2 meters from the floor level.
1.4.65 Lift: An appliance designed to transport persons or materials or vehicle between two or more levels in vertical or substantially vertical directions, by means of a guided car platform
1.4.66 Lift Machine: Part of the lift equipment comprising the motor(s) and the control gear there with, reduction gear (if any), brakes and winding drum or sheave, by which the lift car is raised or lowered.
1.4.67 Lift Well: Unobstructed space within an enclosure provided for the vertical movement of the lift car(s) and any counter weights, including the lift pit and the space for top clearance.
1.4.68 Loft: An intermediary space created by introduction of a slab between floor and ceiling of a room, passage or wherever it is provided with maximum clear height of 1.5 m for storage purposes only.
1.4.69 Mumty or Stair Cover: A structure with a covering roof over a staircase and its landing built to enclose only the stairs for providing protection from weather and not used for human habitation.
1.4.70Masonry: An assemblage of masonry units properly bonded together with mortar.
1.4.71Masonry Unit: A unit whose net cross-sectional area in every plane parallel to the baring surface is 75% or more of its gross cross-sectional area measured in the same plane. It may be either clay brick, stone, concrete block or sandlime brick.
1.4.72 Master Plan: The Master Plan for Delhi approved by the Central Government under the Delhi Development Act. 1957 and the amendments made from time to time.
1.4.73Mezzanine Floor: An intermediate floor between two floor levels above ground floor and at least one side of it form an integral part of space/ floor below.
1.4.74 Non-Combustible: A material which does not burn nor add heat to a fire when tested for combustibility in accordance with good practice.
1.4.75Occupancy Or Use Group: The principal occupancy for which a building or a part of a building is used or intended to be used, for the purposes of classification of a building according to the occupancy, an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it. The occupancy classification shall have the meaning given below unless otherwise spelt out in MPD.
a. Residential Buildings: These shall include any building in which sleeping accommo¬dation is provided for normal residential purposes with or without cooking or dining or both facilities. It includes one or two or multi-family dwellings, lodging or rooming houses, dormi¬tories/hostels, apartment houses and flats and hotels.
b. Educational Buildings: These shall include any building used for school, college, coaching centers (for students more than 20) or day-care purposes for more than 8 hours per week involving assembly for instruction, education or recreation.
c. Institutional Buildings: These shall include any building or part thereof which is used for purposes such as medical or other treatment or care of persons suffering from physical or mental illness, disease or infirmity, care of infants, convalescents or aged persons and for penal or correctional detention in which the liberty of the inmates is restricted. Institutional buildings ordinarily provide sleeping accommodation for the occupants. It includes nursing homes, hospi¬tals, sanatoria, custodial institutions and penal institutions like jails, prisons, mental hospi¬tals, reformatories.
d. Assembly Buildings: These shall include any building or part of a building where group of people not less than 50 congregate or gather for amusement, recreation social, religious, patriotic civil, travel and similar purposes; for example theatres, banquet hall, motion picture houses, assembly halls, auditoria, exhibition halls, museums, skating rinks, gymnasium, restaurants, places of worship, dance halls, club rooms, passenger stations, and terminals of air surface and other public transportation services, recreation piers and stadia.
e. Business Buildings: These shall include any building or part of a building which is used for transaction of business for the keeping of accounts and records for similar pur¬poses, doctors' service facilities, barber shops, city halls, town halls, court houses, libraries shall be classified in this group, so far as principal function of these is transaction of public business and the keeping of books and records.
f. Mercantile Buildings: These shall include any building or part of a building which is used as shops, stores, market, for display and sale of merchandise either wholesale or retail. Office, storage and service facilities incidental to the sale of merchandise and located in the same building shall be included under this group.
g. Industrial Buildings: These shall include any building or part of a building or structure, in which products or materials of all kinds and properties are fabricated, assembled or processed, refineries, gas plants, mills, dairies, factories, etc.
h. Storage Buildings: These shall include any building or part of a building used primarily for the storage or sheltering of goods, wares or merchandise, like warehouses, cold storages, freight depot, transit sheds, store houses/garages, hangars, truck terminals, grain elevators, barns and stables.
i. Hazardous Building: These shall include any building or part of building which is used for the storage, handling manufacture or processing of highly combustible or explosive materials or products which are liable to burn with extreme rapidity and/ or which may pro¬duce poisonous fumes or explosions for storage, handling, manufacturing or processing which involve highly corrosive, toxic or noxious alkalis, acid or other liquids or chemicals pro¬ducing flame, fumes, and explosive, mixtures of dust or which result in the division of matter into fine particles subject to spontaneous ignition.
1.4.76Mechanical Ventilation: The mechanical system(s) or equipment(s) used to circulate air or to replace stale air with fresh air.
1.4.77Open Space: An area, forming an integral part of the site, left open to the sky.
1.4.78 Owner: The owner is a person, group of persons, a Company, Trust, Institute, Registered Body, State or Central Government & its attached/ subordinate Departments, Undertaking and like in whose name the property stands registered in the revenue records/ government records/ any other legal documents up to the satisfaction of Sanctioning Authority.
1.4.79Parapet: A low wall or railing built along the edge of a roof or a floor. See 7.22.
1.4.80 Parking Space: An area enclosed or unenclosed, covered or open, sufficient in size to park vehicles, together with a driveway connecting the parking space with a street or alley and permitting ingress and egress of the vehicles.
1.4.81 Partition: An interior non-load bearing wall, one storey or part storey in height.
1.4.82Party Wall: It includes
a. A wall forming part of a building, and being used or constructed to be used in any part of the height or length of such wall for separation or adorning buildings belonging to different owners or occupied or constructed or adapted to be occu¬pied by different persons; or
b. wall forming part of a building and standing in any part of the length of such wall, to a greater extent than the projection of the footing on one side on grounds of differ¬ent owners.
1.4.83Pantry: A room where food, provisions, dishes or linens are stored and served in an ancillary capacity to the kitchen.
1.4.84 Pergola: An arbor or a passageway of columns supporting a roof of trelliswork on which climbing plants are trained to grow
1.4.85Pedestal: An architectural support or base, as for a column or statue
1.4.86Permit: A permission or authorization in writing by the Sanctioning Authorityto carry out the work regulated by the Bye-laws.
1.4.87Plinth: The portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground.
1.4.88 Plinth Area: The built up covered area measured at the floor level of the basement or of any storey.
1.4.89 Plot / Site: A parcel or piece of land enclosed by definite boundaries and approved by an Sanctioning Authorityas a building site, as part of approved layout plan or special areas/ unauthorized regularized colony/ village abadis/ lal dora/ extended lal dora/ resettlement colonies and slum & JJ cluster/ Rehabilitation Colonies.
1.4.90 Podium: A raised platform constructed as top most level of any single/ multilevel parking which can be used for landscaping, plantation, tot-lot, swimming pool, deck, assembly space, movement, building tower/s, parking etc.
1.4.91 Porch: A covered surface supported on pillars or otherwise for the purpose of pedes¬trian or vehicular approach to a building.
1.4.92 Portico: A porch or walkway with a roof supported by columns, often leading to the entrance of a building
1.4.93 Pre-Code Building Permit: Validity of building permit granted before the enforcement of these building bye laws.
1.4.94 Ramp: A sloping surface joining two different levels, as at the entrance or between floors of a building.
1.4.95 Refuge Area: A location in a building designed to hold occupants during a fire or other emergency, when evacuation may not be safe or possible. Occupants can wait there until rescued or relieved by firefighters.
1.4.96 Road/Street: Any highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thoroughfare or not, over which the public have a right of passage or access or have passed and had access uninterruptedly for a specified period, whether existing or proposed in any scheme, and includes all bunds, chan-nels, ditches, storm-water drains, culverts, sidewalks, traffic islands, roadside trees and hedges, retaining walls, fences, barriers and railings within the street lines.
1.4.97 Road/Street Level or Grade: The officially established elevation or grade of the central line of the street upon which plot fronts and if there is no officially established grade, the existing grade of the street at its mid-point.
1.4.98 Road/Street Line: The line defining the side limits of a street.
1.4.99 Room Height: The vertical distance measured from the finished floor surface to the finished ceiling surface.
1.4.100 Row Housing: A row of houses with only front, rear and interior open spaces.
1.4.101 Semi-Detached Building: A building detached on three sides with open spaces.
1.4.102 Service Road: A road/lane provided at the rear or side of a plot for service purposes.
1.4.103 Set back area: An area between the plot boundary and the setback line, size of which is defined as per the provisions of MPD.
1.4.104 Set Back Line: A line usually parallel to the plot boundaries or center line of a road and laid down in each case by the Sanctioning Authority or as per recommendations of Master/Zonal Plan, beyond which nothing can be constructed towards the plot boundaries, excepting with the permission of the Sanctioning Authority.
1.4.105 Site Corner: A site at the junctions of and fronting on two or more intersecting streets.
1.4.106 Site, Depth of: The mean horizontal distance between the front and rear site boundaries.
1.4.107 Site, Double Frontage: A site, having a frontage on two streets other than a corner plot.
1.4.108 Site, Interior or Tandem: A site, access to which is by a passage from a street whether such passage forms part of the site or not.
1.4.109 Soffit: The lowest underside of a structural member such as a beam, coffer slab or flat slab.
1.4.110 Stack parking: For parking cars in which a hydraulic lift/ platform is used to place cars in spaces on top of each other.
1.4.111 Stilt: Stilt or stilt floor means non habitable portion of a building above ground level consisting of structural columns supporting the super structure with at least two sides open for the purpose of parking cars, scooters, cycles and landscaping. See 7.15.1.
1.4.112 Storage: A space where goods of any kind or nature are stored.
1.4.113 Store Room: A room used as storage space.
1.4.114 Storey: The portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it.
1.4.115 Skywalk: An elevated, usually enclosed walkway between two buildings.
1.4.116 Terrace: A flat open to sky roof of a building or a part of a building having parapet, not being a cantilever structure.
1.4.117 To Abut: To be positioned juxtaposed to a road, lane, open space, park, building etc.
1.4.118 To Erect:To erect a building means: To erect a new building on any site whether previously built upon or not; To re-erect any building of which portions above the plinth level have been pulled down, burnt or destroyed; and conversion from one occupancy to another.
1.4.119 Sunken Courtyard: An open sunken space within the plot to provide natural light and ventilation subject to set back restriction with clear fire tender movement passage.
1.4.120 Travel Distance: Horizontaldistance to be travelled from any point in a building to a protected escape route, external escape route or final exit.
1.4.121 Travellator: A power driven moving path used for transporting people and goods within the same level.
1.4.122 Trellis: A structure of open latticework, especially one used as a support for vines and other creeping plants.
1.4.123 Unsafe Building: Unsafe buildings are those which are structurally unsafe, insanitary or not provided with adequate means of egress or which constitute a fire hazard or are other¬wise dangerous to human life or which in relation to existing use constitute a hazard to safety or health or public welfare, by reason of inadequate maintenance, dilapidation or abandon-ment and are a danger to human life.
1.4.124 Verandah: A covered area, 2.4M deep with at least one side open to the outside with the exception of 1.0 m high parapet/ railing on the upper floors to be provided on the open side.
1.4.125 Ventilator: An opening in a wall for ventilating the space inside.
1.4.126 Water Closet (WC): A privy with arrangement for flushing the pan with water. It does not include a bathroom.
1.4.127 Width of Road: The whole extent of space within the boundaries of road when applied to a new road, as laid down in the surveys of the city or development plans and measured at right angles to the course or intended course of direction of such road.
1.4.128 Window: An opening to the outside other than a door which provides all or part of the required natural light or ventilation or both to an interior space and not used as a means of egress/ingress.
1.4.129 Non-Ambulatory disabilities: Impairment that, regardless of cause or manifestation, for all practical purposes, confined individuals to wheel chair.
1.4.130 Semi-Ambulatory disabilities: Impairment that cause individuals to walk with difficulty or insecurity. Individuals using braces or crutches, amputees, arthritis, spastics and those, with pulmonary and cardiac ills shall be semi-ambulatory.
1.4.131 Hearing Disabilities: Deafness or hearing handicaps that might make an individual insecure in public areas because he is unable to communicate or hear warning signals.
1.4.132 Sight Disabilities: Total blindness or impairment affecting sight to the extent that the individual functions in public areas is insecure or exposed to danger.
1.4.133 Wheel chair: Chair used by disabled people for mobility.
1.4.134 Private establishment: means a company, firm, cooperative or other society, associations, trust, agency, institution, organization, union, factory or such other establishment as the appropriate Government may, by notification, specify.
1.4.135 Public building: means a Government or private building, used or accessed by the public at large, including a building used for educational or vocational purposes, workplace, commercial activities, public utilities, religious, cultural, leisure or recreational activities, medical or health services, law enforcement agencies, reformatories or judicial foras, railway stations or platforms, roadways bus stands or terminus, airports or waterways.