This report to accompany the application for Building Permit.
-
In case information on items 3, 10, 17, 18 and 19 cannot be given at this time, it should be submitted at least one week before commencement of construction.
Part 1: General Data
| Sl No | Description | Information | Notes |
|---|---|---|---|
| 1 | Address ofthe building • Name ofthe building • Plot number • Subplot number • TPS scheme a. Name b. Number • Locality/Township • District | ||
| 2 | Name ofowner | ||
| 3 | Name ofBuilder on record | ||
| 4 | Name ofArchitect/Engineer on record | ||
| 5 | Name ofStructural engineer on record | ||
| 6 | Use ofthe building | ||
| 7 | Number ofstoreys above ground level (including storeys to be added later, if any) | ||
| 8 | Number ofbasements below ground Level | ||
| 9 | Type ofstructure • Load bearing walls • R.C.C frame • R.C.C frame and Shear walls • Steel frame | ||
| 10 | Soil data • Type ofsoil • Design safe bearing capacity | IS: 1893 Cl. 6.3.5.2 IS: 1904 | |
| 11 | Dead loads (unit weight adopted) • Earth • Water • Brick masonry • Plain cement concrete • Reinforced cement concrete • Floor finish • Other fill materials • Piazza floor fill and landscape | IS: 875 Part 1 | |
| 12 | Imposed (live) loads | IS: 875 Part 2 |
| • Piazza floor accessible to Fire Tender • Piazza Floor not accessible to Fire Tender. 11Floor loads. 11Roof loads | |||
|---|---|---|---|
| 13 | Cyclone / Wind • Speed • Design pressure intensity | IS: 875 Part 3 | |
| 14 | Seismic zone | IS:1893 2002 | |
| 15 | Importance factor | IS:1893 (2002) Table 6 | |
| 16 | Seismic zone factor(Z) | IS:1893 Table 2 | |
| 17 | Response reduction factor | IS: 1893 Table-7 | |
| 18 | Fundamental natural period - approximate | IS: 1893 Cl. 7.6 | |
| 19 | Design horizontal accelerationspectrum value (Ah) | IS: 1893 Cl. 6.4.2 | |
| 20 | Expansion / Separation Joints |
(a)
Part 2: Load bearing masonry buildings
| Sl No | Description | Information | Notes |
|---|---|---|---|
| 1 | Building category | IS:4326 Cl. 7 read with IS: 1893 Bld/Zone II III IV V Ord. B C D E Important C D E E | |
| 2 | Basement Provided | ||
| 3 | Number offloors including Ground Floor (all floors including stepped floors in hill slopes) | ||
| 4 | Type ofwall masonry | ||
| 5 | Type and mix ofMortar | IS:4326 Cl. 8.1.2 | |
| 6 | Re: size and position ofopenings (See note No.1) • Minimum distance (b5) • Ratio (b1+b2+b3)/l1 or (b6+b7)/l2 • Minimum pierwidth between consequent opening (b4) • Vertical distance (h3) • Ratio ofwall height to thickness4 • Ratio ofwall length between cross wall to thickness | IS:4326 Table 4, Fig.7 | |
| 7 | Horizontal seismic band • at plinth level | P IP NA | (see note no.2) IS:4326 Cl. 8.4.6 |
| • at window sill level • at lintel level • at ceiling level • at eave level ofsloping roof • at top ofgable walls • at top ofridge walls | IS:4326 Cl. 8.3 IS:4326 Cl. 8.4.2 IS:4326 Cl. 8.4.3 IS:4326 Cl. 8.4.3 IS:4326 Cl. 8.4.4 | ||
|---|---|---|---|
| 8 | Vertical reinforcing bar • at corners and Tjunction of walls • at jambs ofdoors and window openings | IS:4326 Cl. 8.4.8 IS:4326 Cl. 8.4.9 | |
| 9 | Integration ofprefab roofing/flooring elementsthrough reinforced concrete screed | IS:4326 Cl. 9.1.4 | |
| 10 | Horizontal bracings in pitched truss • in horizontal plane at the level of ties • in the slopes ofpitched Roofs |
(b)
Part 3: Reinforced concrete framed buildings
| Sl No | Description | Information | Notes |
|---|---|---|---|
| 1 | Type ofBuilding Regular frames Regular frames with Shear walls Irregular frames Irregular frames with shear walls Soft storey | IS: 1893 Cl. 7.1 | |
| 2 | Number ofbasements | ||
| 3 | Number offloors including ground floor | ||
| 4 | Horizontal floor system Beams and slabs Waffles Ribbed Floor Flat slab with drops Flat plate without drops | ||
| 5 | Soil data Type of soil Recommended type of foundation - Independent footings - Raft - Piles Recommended bearing capacity of soil Recommended, type, length, diameter and | IS: 1498 |
| load capacity ofpiles Depth of water table Chemical analysis of ground water Chemical analysis of soil | |||
|---|---|---|---|
| 6 | Foundations Depth below ground level Type • Independent • Interconnected • Raft • Piles | ||
| 7 | System ofinterconnecting foundations Plinth beams Foundation beams | IS: 1893 Cl. 7.12.1 | |
| 8 | Grades ofconcrete used in different parts of Building | ||
| 9 | Method ofanalysis used | ||
| 10 | Computer software used | IS: 1893 Cl. 7.9 | |
| 11 | Torsion included | ||
| 12 | Base shear a. Based on approximate fundamental period b. Based on dynamic analysis c. Ratio ofa/b | IS: 1893 Cl. 7.5.3 | |
| 13 | Distribution ofseismic forces along the height ofthe building | IS:1893 Cl. 7.7 (provide sketch) | |
| 14 | The column ofsoft ground storey specially Designed | IS:1893 Cl. 7.10 | |
| 15 | Clear minimum cover provided in • Footing • Column • Beams • Slabs • Walls | IS: 456 Cl. 26.4 | |
| 16 | Ductile detailing ofRC frame • Type ofreinforcement used • Minimum dimension ofbeams • Minimum dimension ofcolumns • Minimum percentage ofreinforcement of beams at any cross section • Maximum percentage ofreinforcement at any section of beam • Spacing oftransverse reinforcement in 2-d length of beams near the ends • Ratio ofcapacity ofbeams in shear to capacity of beams in flexure • Maximumpercentage ofreinforcement in column • Confining stirrups near ends ofcolumns and in beam-column joints a. Diameter b. Spacing • Ratio of shear capacity of columns to maximum seismic shear in the storey | IS: 456 Cl. 5.6 IS:13920 Cl. 6.1 IS:13920Cl. 7.1.2 IS: 456 Cl. 26.5.1.1(a) IS:13920 Cl.6.2.1IS: 456 Cl. 26.5.1.1(b) IS:13920 Cl.6.2.2IS: 13920 Cl. 6.3.5 IS: 456 Cl. 26.5.3.1 IS: 13920 Cl. 7.4 |
(c)