5.4.1 Permissibility
Permissions for construction of Single Screen Cinema, Miniplex and Multiplex shall be permitted as per master plan zoning regulations. Under multiplex, cinema halls, commercial theatres and other entertainment facilities shall be allowed.
5.4.2 Minimum Plot Size
Minimum plot size for single screen cinema, miniplex, and multiplex shall be as follows.
| Type of Building | Minimum Plot Size (sqm) |
|---|---|
| Single Screen Cinema | 500 |
| Miniplex (2 screens) | 700 |
| Multiplex | 3000 |
The above-mentioned plot size for multiplex shall not apply if multiplexes are proposed on the same land after demolishing existing cinema halls or in the sites identified for multiplexes in the sector plan/lay-out plan which is approved by the competent level, i.e., the existing area of the plot shall be valid.
5.4.3 Means of Access
The minimum road width for proposed site/plot for construction of single screen cinema, miniplex and multiplex shall be as follows.
| Type of Building | Minimum Road width (m) |
|---|---|
| Single Screen Cinema | 12 |
| Miniplex (2 screens) | 12 |
| Multiplex | 18 |
The above restriction shall not apply if a multiplex is proposed on the same land after demolishing their place by demolishing existing cinema halls or in place of the sites marked for multiplex in the master plan/zonal plan/sector plan/lay-out plan which is approved by the competent authority.
5.4.4 Ground Coverage and FAR
The maximum ground coverage after ensuring the minimum setbacks may be utilized. The maximum permissible FAR (including additional FAR available on purchasable basis) for multiplexes in commercial areas shall be permissible as follows:
| FAR Cinema, Miniplex, Multiplex | Road Width (Upto12m) | Road Width (>12 -24m) | Road Width (>24 - 45m) | Road Width (>45m) | |||||||||
| BFAR | PFAR | PPFAR | MFAR | PFAR | PPFAR | MFAR | PFAR | PPFAR | MFAR | PFAR | PPFAR | MFAR | |
| Built-up Area | |||||||||||||
| Cinema, Miniplex, Multiplex | 2.0 | NA | NA | NA | 1.0 | 1.0 | 4.0 | 2.0 | 3.0 | 7.0 | 2.0 | UR | UR |
| Non-Built-up Area | |||||||||||||
| Cinema, Miniplex | 2.0 | NA | NA | NA | 1.0 | 1.0 | 4.0 | 2.0 | 3.0 | 7.0 | 2.0 | UR | UR |
| Multiplex | 3.0 | NA | NA | NA | 1.5 | 1.5 | 6.0 | 3.0 | 4.5 | 10.5 | 3.0 | UR | UR |
Note-1: BFAR – Base FAR, PFAR – Purchasable FAR, PPFAR – Premium Purchasable FAR, MFAR – Maximum Permissible FAR which includes Base FAR, UR – Unrestricted FAR.
Note-2: In green building, additional FAR over and above maximum permissible FAR shall be provided as per Chapter 9.3 of the building byelaws.
5.4.5 Ratio of activities
(i) Provision for minimum two cinema screens under miniplex and multiplex shall be mandatory.
(ii) In case of construction of cinema and miniplex in non-commercial areas, 20 percent floor area shall be utilized for commercial and other entertainment facilities.
(iii) In case of construction of multiplex in non-commercial areas, construction of cinema hall shall be permitted on minimum of 30 percent of the total floor area and the remaining 70 percent shall be utilized for commercial and other entertainment facilities.
(iv) In case of construction of multiplex in commercial areas, then the above restriction shall not apply.
5.4.6 Minimum Setback
(i) Minimum setbacks for cinema, miniplex and multiplex shall be per paragraph 3.2.4 of the building byelaws.
(ii) For multiplex buildings, provision of adequate "circulation space" for the vehicles to move from parking lot towards the 18-meters-and-wider access road shall be mandatory.
5.4.7 Parking Requirements
Parking requirements for cinema, miniplex and multiplex shall be as per paragraph 3.3.4 of the building byelaws.
5.4.8 Basement
(i) The provisions for basement for cinema, miniplex and multiplex shall be as per paragraph 3.3.3 of the building byelaws.
(ii) Construction of a screen in the basement shall not be permitted.
5.4.9 Other requirements
Planning, designing and firefighting arrangements of the cinema hall shall be ensured as per the relevant provisions of Uttar Pradesh Cinematograph Rules, 1951 and National Building Code. In a multiplex, essential services like drinking water system, toilets, canteen, etc. can be provisioned in common as per the prescribed standards.
5.4.10 Redevelopment of existing cinema halls
5.4.10.1. The land use of the cinema plot or existing cinema hall planned before the creation of the authority, which is part of the layout plan approved at the competent level, shall be considered as cinema hall (commercial), even if their land use is shown otherwise in the master plan.
5.4.10.2. In case the land use level of the plots/picture halls planned for the purpose of the cinema hall is not determined under the master plan, it shall be considered as commercial.
5.4.10.3. Under the layout plan approved by the competent authority, since the land use of the plot planned for the cinema hall/existing cinema hall is commercial, the action of land use change shall not be necessary, hence land use change fee shall not be payable.
5.4.10.4. The ground coverage and FAR allowed for cinema hall/multiplex shall be as per the terms and conditions of allotment/lease. If there is no above provision in the lease, then as per the provisions of Multiplex as per these byelaws shall be permissible. Purchasable FAR shall be allowed as per rules over and above the permissible FAR as per the terms of allotment/lease or the permissible FAR as per building construction and development byelaws, as the case may be.