For all public buildings or building complexes with a connected load of 100 kW or greater or having a contract demand of 120 KV or greater and intended to be used for commercial purpose, Energy Conservation Building Code (ECBC) standards, as amended from time to time, shall be applicable.
Occupancy sensors, movement sensors, lux level sensors, etc, may also be considered as switching options for lights, fans, TV, etc, for different closed spaces.
13.2.1 Energy Conservation through Efficient Lighting
A substantial portion of the energy consumed on lighting may be saved by utilization of daylight and rational design of supplementary artificial lights. In common areas, cost effective and energy saving LED/solar lights may be provided.
All exterior lighting may use solar-powered lighting and be fitted with automatic controls so that the lights do not operate during daylight hours.
13.2.2 Energy Conservation through Efficient HVAC
Maximum possible use shall be made of wind induced natural ventilation. An adequate number of circulating fans shall be installed to serve all the rooms during summer months in hot and warm regions and dry and humid conditions.
13.2.3 Solar Energy
All efforts shall be made towards optimum and efficient use of renewable energy in buildings and, thereby reduce the building’s dependency on fuels derived from conventional sources. This may be achieved by installing solar water heater and Solar Photovoltaic (SPV) systems. To facilitate the installation of such a solar system, at least 25-50 percent of roof area may be utilized for installation of solar water heater and SPV system in new buildings.
13.2.3.1 Solar Photovoltaic Power Generation System
All plots having size 500 sqm and above shall install solar photovoltaic power generation system. This should also be encouraged for plots smaller than 500 sqm. The power generated may be used for inhouse utilization or for transfer to the grid.
13.2.3.2 Solar Water Heating System
No new building in the following categories in which there is a system of installation for supplying hot water shall be built unless the system of the installation is also having an auxiliary solar assisted water heating system. Solar water heating systems shall be provided in the following buildings:
a) hotels, lodges, guest houses, service apartments;
b) institutional buildings (hospitals and nursing home);
c) schools, colleges, universities, technical institutions, training centres;
d) assembly buildings (auditorium, community halls, wedding/banquet halls, etc);
e) barracks of armed forces/paramilitary forces and police forces;
f) hostels for schools, colleges, and training centres with more than 100 students.
13.2.4 Energy Efficiency Compliance
Environmental Conditions required for buildings (amended from time to time):
| Built-up area | Requirement |
| Category-A (5000-20000 sqm) | • In common areas, LED/ solar lights must be provided. |
| Category-B (20000 -50000 sqm) | • In common areas, LED/ solar lights must be provided. • At least 1% of connected applied load generated from renewable energy source such as photovoltaic cells or windmills or hybrid should be provided. • As per the provisions of the Ministry of New and Renewable energy solar water heater of minimum capacity 10 litres/4 persons (2.5 litres per capita) shall be installed. • Use of fly ash bricks: Fly ash should be used as building material in the construction as per the provisions of Fly Ash Notification of September 1999 and as amended from time to time. |
| Category-C (50000-150000 sqm) | |
| Category-C (50000-150000 sqm) | • Use of concept of passive solar design of buildings using architectural design approaches that minimize energy consumption in buildings by integrating conventional energy-efficient devices, such as mechanical and electric pumps, fans, lighting fixtures and other equipment, with the passive design elements, such as building orientation, landscaping, efficient building envelope, appropriate fenestration, increased day lighting design and thermal mass. • Optimize use of energy systems in buildings that should maintain a specific indoor environment conducive to the functional requirements of the building by following mandatory compliance measures (for all applicable buildings) as recommended in the Energy Conservation Building Code (ECBC) 2007 of the Bureau of Energy Efficiency, Government of India. |
13.3 Natural Drainage
Environmental Conditions required for buildings (amended from time to time):
| Built-up area | Requirement |
| Category-A (5000-20000 sqm) | The inlet and outlet point of natural drain system should be maintained with adequate size of channel for ensuring unrestricted flow of water. |
| Category-B (20000 -50000 sqm) | |
| Category-C (50000-150000 sqm) |