2.3.1 Key Plan
A ‘Key Plan’ drawn to a scale of not less than 1: 10,000 shall be submitted along with application/ notice for development permission or building permission, showing boundary and location of the site (along with north point indicator and scale) with respect of neighbourhood landmarks in areas where there are no approved layout plans.
2.3.2 Site Plan for Development Permission
(i) Plot number along with details of neighbouring land shall be given in the Site Plan.
(ii) If proposed land is contiguous with neighbouring land owned by same applicant, and whose subdivision is already approved, the details of public amenities provided in such land and all streets within it opening out in the site for which permission is being sought, shall include:
(iii) The means of access from existing street, distance from it, mentioning name and width of the street to the site proposed for development.
(iv) The position of all existing structures and features like high-tension lines, telegraph and electrical poles, underground pipe lines, trees, buildings and railway lines etc. within a distance of 30 meters from the boundary of the site.
(v) All major physical characteristics of the land proposed to be developed which include the approximate location and size of any water body, flood affected areas, and contours at an interval
of 0.3 meters in case of a site having a slope of more than 1:20.
(vi) Location of the site in Master Plan / Sector Plan.
(vii) North point and scale used.
2.3.3 Layout/ Sub-division Plan for Development Permission
The layout/sub-division plan to be submitted along with the application for development permit shall be drawn to a scale of 1:500 for plots up to 10 hectares, on a scale of 1:1000 for plots above 10 hectares but less than 50 hectares, and on a scale of 1:2000 for plots more than 50 hectares. The layout plan shall show the following details:
| 1 | North Point and scale used. |
|---|---|
| 2 | The location of all proposed and existing roads with their width. |
| 3 | Plan showing dimension within plots/premises along with setback and method of plotted development like row-housing, semi-detached or detached. In case of group housing/ clustered development, the distance between blocks and corresponding height of blocks. |
| 4 | Services plan showing the location of drains, water supply and sewer networks, electric lines, solid waste disposal, and other public facilities and services along with their linkage with existing/proposed facilities. |
| 5 | Analysis indicating size, area and use of all the plots and different premises/uses proposed in the layout/sub-division plan. |
| 6 | A statement indicating the total area of the site, area utilized under roads, open spaces, residential, commercial, community facilities and other public uses, proposed in the layout/ sub-division plan along with their percentage with references to the total area of the site. |
| 7 | In case ofproposed sub-division for plots situated in built-up area, in addition to the details mentioned above (1) to (6), the means of access to the proposed sub-division from existing street shall also be shown. |
| 8 | Landscape plan (with plantation). |
| 9 | Sustainability provisions outlined in Chapter-13 shall be ensured by competent authority for conservation and recharging of ground water. |
2.3.4 Specifications for Sub-division of land
The following specifications and details shall be enclosed to obtain permission for the sub-division of land:
(i) Details of general specification for development works in the proposed area viz., general specification of roads drains (side drains) and streets along with their slope, and paving provision for water supply, management and disposal of sewerage and garbage, street lighting, playground park and community facilities.
(ii) Existing external infrastructure facilities near the site such as sewerage disposal site, drainage (Nallah etc.) main road, electric supply system, source of water supply etc.
(iii) In case of industrial units, type and quantities of effluents.
2.3.5 Site Plan for Building Permission
The site plan to be sent along with the application for building permit shall be drawn to a scale of 1:100 for plots up to 500 sqm in size, on a scale of 1:500 for plots above 500 sqm in size and on a scale of 1:1000 for plots above 10,000 sqm. The plan shall show the following details:
| 1. | The boundaries of the site and any contiguous land belonging to the owner thereof. |
|---|---|
| 2. | The names of the streets on which the building is proposed to be situated, if any. |
| 3. | All existing buildings standing on, over or under the site. |
| 4. | The position of the site in relation to neighbouring street. |
| 5. | The position of the building and of all other buildings, if any, which the applicant intends to erect upon his contiguous land referred to in (1) in relation to. a) The boundaries of the site and in case where the site has been partitioned, the boundaries of the portion; owned by the applicant and also of the portions owned by others. b) All adjacent streets / buildings and premises within a distance of 12 meters of the site and of the contiguous land, if any, referred to in (1); and c) If there is no street within a distance of 12 meters of the site, the nearest existing street. |
| 6. | The means of access from the street to the building, and to all other buildings, if any which the applicant intends to erect upon his contiguous land, referred to in (1). |
| 7. | Space to be left around the building to secure un-interrupted ventilation, admission of light and access, through setbacks (front, rear and sides of the building) and parking spaces. |
| 8. | The width of the street, if any, in front, at the sides or rear of building. |
| 9. | Any existing physical features such as well, drains, trees, overhead electric supply lines etc. |
| 10. | Water supply lines, taps up to discharge point, drainage lines and roof top rainwater harvesting system. |
| 11. | The direction of north point relative to the plan of the buildings. |
| 12. | The ground area of the whole property and the breakup of covered area on each floor with the calculation for percentage covered in each floor in terms of the total area of the plot as required under the Byelaws governing the coverage of the area. |
| 13. | Parking plans indicating the parking spaces wherever required. |
| 14. | Building number or plot number of the property on which the building is intended to be erected. |
2.3.6 Building Plan
The plans of the building, elevations and sections accompanying the application/notice with dimensions shall be drawn to a scale of 1:50 for plots measuring up to 250 sq.m., for plots measuring above 250 sq.m. to a scale of 1:100, and for plots measuring 2000 sq.m. and above to a scale of 1:200 with following details:
| a. | Include floor plans of all floors together with the covered area clearly indicating the size and spacing of all frame members and sizes of rooms and the position and width of staircases, ramps and other exit ways, lift ways, lift machine room and lift pit details. |
|---|---|
| b. | Show the use or occupancy of all parts of the building. |
| c. | Show exact location of essential services, for example toilet, water closet, sink, bath, water supply, drainage and connection to soak pit/septic tank or sewer line for sewage disposal. |
| d. | Include sectional drawing clearly showing the sizes of the footings, thickness of basement wall, wall construction, size and spacing of framing members, floor slabs and roof slabs with their materials. The section shall indicate the heights of building and rooms and also the heights of the parapet and drainage |
| and the slope of the roof. At least one section shall be taken through the staircase, kitchen and toilet, bath and water closet. | |
| e. | Show all elevations for abutting roads. |
| f. | Indicate details of service privy (running water toilets), if any. |
| g. | Give dimensions of the projected portions beyond the permissible building line. |
| h. | Include terrace plan indicating the drainage and the slope of the roof. |
| i. | Give indications of the north point relative to the plan. |
| j. | Details of parking spaces provided. |
| k. | Give indication of all doors, windows and other openings including ventilators |
| l. | Maps shall show the provisions for rainwater harvesting, solar water heating, wastewater recycling, and waste management as outlined in Chapter-13 of the byelaws. |
| m. | Such other particulars as may be required to explain the proposal clearly and as prescribed by the Authority. |
2.3.7 Building Plans for Multi-storeyed/ Special Buildings
(i) For multi-storeyed buildings, which are above 4 storeyed and buildings above 15 meters in height and for special buildings like assembly, institutional, industrial storage and hazardous occupancies as defined under paragraph 1.2. 16 (a to k) the following additional information shall be furnished/ indicated in the building plans in addition to the item (a) to (l) of Building Bye-Laws paragraph 2.3.6.
| a. | Access to fire appliances/ vehicles with details of vehicular turning circle/ and clear motorable access way around the building. |
|---|---|
| b. | Size (width) of main and alternate staircase along with balcony approach, corridor, ventilated lobby approach. |
| c. | Location and details of lift enclosures. |
| d. | Location and size of fire lift. |
| e. | Smoke-stop lobby/ door where provided. |
| f. | Refuse chutes & chamber, services duct (sanitation, electric & telecommunication), if required. |
| g. | Vehicular parking spaces. |
| h. | Refuge area if any. |
| i. | Details of building services-air conditioning system with position of dampers, mechanical ventilation system, electrical services, boilers, gas pipes etc. |
| j. | Details of exits including provision of ramps, etc. for hospitals and special risks. |
| k. | Location of generator, transformer, and switchgear room. |
| l. | Smoke exhaust system if any. |
| m. | Details of fire alarm system network. |
| n. | Location of centralized control, connecting all fire alarm systems, built-in fire protection arrangements and public address system, etc. |
| o. | Location and dimension of static water storage tank and pump room. |
| p. | Location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers, CO2 installation etc. |
| q. | Location and details of first aid firefighting equipment/installation. |
| r. | The proper signs/symbols and abbreviation of all fire-fighting systems shall be shown as per the relevant BIS Codes. |
(ii) In addition to those buildings specified in (i), for construction approval of buildings such as waterworks and overhead tanks, bridges and culverts, power generation centres and power substations, power towers, photo galleries, auditorium, meeting hall, educational institutions, bus
2.3.8 Services Plan and Water Supply Provisions
(i) Plans, elevations and sections of private water supply, sewage disposal system and details of building services, where required by the Authority, shall be made available to a scale not less than 1: 100.
(ii) Besides the normal drawings, which are submitted for the sanction of any building, a proper landscape plan, a circulation plan indicating vehicular and pedestrian movement and parking and an urban design scheme where necessary, shall be submitted for sanction by the Authority.
(iii) Specifications: General specification of the proposed construction giving type and grade of material proposed to be used in the form given in paragraph 11.1 duly signed by the engaged Competent Professional for building plan design (as per Chapter-14 of the byelaws) may be shown accompanying the application/notice as the case may be.
2.4 Signing of Plans
2.4.1 Signing of Layout Plans
All layout plans before submission to the Authority shall be signed by the owner(s) and the Licensed Technical Person.
2.4.2 Signing of Building Plans
(i) All building plans before submission to the Authority shall be signed by the owner(s) and the Licensed Technical Person (except as given in paragraph 2.5.1 of these byelaws).
(ii) This shall not apply in case of standard designs/ building plans as described in paragraph 2.7.2.1.