4.1 Plotted Development - Single/ Multi-units.
4.1.1 General Requirements
(i) Permission for residential plotted development (single/ multi-units) shall be given:
a. On all plots in residential areas proposed in the master plan/ zonal development plan.
b. In all layouts approved or developed by the Authority.
(ii) Single-unit refers to residential building having one independent residential unit on each floor or combination of floors with three or less storeys and height not exceeding 15-meters.
(iii) Multi-unit refers to residential building having one or more independent residential units on each floor with four or less storeys and height not exceeding 17.5-meters (including mandatory stilt).
4.1.2 Minimum Plot Size
(i) The minimum plot size for single units shall be 40 square meters for non-built-up area and there shall be no restriction on plot size for built-up area.
(ii) The minimum plot size for multi units shall be 150 square meters.
(iii) In case of a multi unit, the minimum carpet area of each independent residential unit shall be 60 square meters.
4.1.3 Means of Access
(i) For single units, the minimum width of the road shall be 4.0 meters in built-up areas and 9-meters in in non-built-up areas. However, for non-built-up area, 7.5-meter-wide access road is permissible in case plots are located only on one side of the road.
(ii) For multi-units, the minimum width of road shall be 9-meters.
4.1.4 Maximum height of building
The maximum height of the building shall be 15-m including stilt for single unit and 17.5 meters including mandatory stilt floor for multi-unit.
4.1.5 Minimum Setback
Minimum setbacks for residential buildings in plotted development for single/multi-units shall be as per paragraph 3.2.4 of the building byelaws.
4.1.6 Ground Coverage and FAR
The ground coverage and FAR of the buildings shall be as follows:
| Plot Area (sqm) | Ground Coverage (%) | Base FAR | Max. Permissible FAR |
|---|---|---|---|
| ≥40 to 150 | Max. coverage after ensuring setbacks | 2.00 | 2.0 |
| >150 to 300 | Max. coverage after ensuring setbacks | 1.80 | 2.0 |
| >300 to 500 | Max. coverage after ensuring setbacks | 1.75 | 2.0 |
| >500 to1200 | Max. coverage after ensuring setbacks | 1.50 | 2.0 |
| >1200 | Max. coverage after ensuring setbacks | 1.25 | 2.0 |
Note-1: For all housing projects having more than one unit, a 10% each of the total units shall be mandatorily reserved for Economically Weaker Section (EWS) and Lower Income Group (LIG) housing respectively. For plots less than 4 Ha, provision to deposit shelter fee shall be applicable. The mandatory EWS/LIG plots/units to be built as per the government policy shall be treated free of FAR and the corresponding incentive FAR (as calculated on carpet area of EWS/LIG units) shall also be permissible. For plots less than 4 Ha, in case EWS/LIG plots/units are not constructed and shelter fee is deposited, then in lieu of the same, the proportionate incentive FAR shall be allowed.
4.1.7 Parking Requirements
Parking requirements for residential plotted development shall be as per paragraph 3.3.4 of the building byelaws.
4.1.8 Other requirements
(i) Before multi- units are allowed on the above mentioned plots, development fee shall be deposited by the applicant as per the provisions of Uttar Pradesh Urban Planning and Development (Determination, Levy and Collection of Development Fee) Rules, 2014 as amended time to time.
(ii) The provisions of Uttar Pradesh Apartment (Promotion of Construction, Ownership and Maintenance) Act, 2010 and the rules and bye-laws made thereunder shall be effective in case of multi-units.