3.1.4.1 Standards for community facilities
| Sl. | Category | Standards | Minimum plot area |
|---|---|---|---|
| 1. | Education Facilities | ||
| (a) | Nursery School | Per 2500 population - 1 | 500 square meters |
| (b) | Primary school | Per 5000 population - 1 | 1000 square meters |
| (c) | Junior High School / High School | On 7500 population - 1 | 2000 square meters |
| (d) | Inter College | Per 10000 population - 1 | 2000 square meters |
| (e) | Degree College/Post Graduate College/ Technical Education | For population 80,000 to 1,00,000- 1 | Urban area - 5000 square meters; |
| (f) | Engineering College/ Universities | Per 10,00,000 population - 1 | 2.0 hectares. |
| (g) | Dental College | Per 10,00,000 population - 1 | 2.0 hectares |
| 2. | Medical Services | ||
| (a) | Non-Bedded Medical Establishments (Diagnostic Centre / OPD clinics / dispensary / Pathology Lab / Veterinary Clinics) | Per 15000 population - 1 | 100 square meters |
| (b) | Nursing Homes / Maternity Hospitals/ Small Hospitals/ (Up to 50 beds)/ Veterinary Hospitals | Per 45000 population - 1 | 300 square meters |
| (c) | Hospitals (>50 beds) | Per 100000 population - 1 | 3000 square meters |
| (d) | Medical College | Per 10,00,000 population - 1 | As per MCI/ NMC norms |
| 3 | Other services | ||
| (c) | Police Station (including staff accommodation) | Per 50,000 population - 1 | 4000 square meters of which 800 square meters shall be built up area. |
| (d) | Police post (including staff quarters) | Per 15000 population - 1 | 1500 square meters which shall have built up area as per requirement. |
| (e) | Fire station (including staff accommodation) | ||
| (i) Category-A cities | 4 lakh population and 10 square km area. | 12400 square meters of which there shall be 5600 square meters of built-up area. | |
| (ii) Category-B cities | 2.5 lakh population and 10 square km area. | 10000 sq.m. of which there shall be 4200 sq.m. built up area. | |
| (iii) Category-C cities | 2 lakh population and 10 square km area. | 8000 sq.m. of which 3500 sq.m. shall be built up area. |
| Sl. | Category | Standards | Minimum plot area | ||
| (iv) Tehsil and other towns | For 1 lakh population and 3.00 square km area. | 6000 square meters of which there shall be 2800 square meters of built-up area. | |||
| (g) | Electric Sub-station | 11 KVA | Per 15000 population - 1 | 500 square meters | |
| 33 KVA | - | 1.0 acre | |||
| 132 KVA | - | 5.0 acre | |||
| 220 KVA | Per 500000 population - 1 | 10.0 acre | |||
| 4. | Social and cultural facilities | ||||
| (a) | Marriage Hall/ Community centre | Per 25000 population – 1 | 750 square meters | ||
| 5. | Commercial | ||||
| (a) | Commercial Use | For every 500 population – 1 shop | Minimum 10 square meters per each shop | ||
| For every 500 population – 1 informal sector kiosk/booth | Maximum 10% of total area (including office use) as per Chapter-5 | ||||
| 6. | Mixed Use | Maximum 10% of total area may be used as mixed-use plots as per Chapter-8 | |||
| 7. | Sports activities | ||||
| (a) | Neighbourhood Sports Centre | For every 15000 population - 1 | 1.5 hectare | ||
| (b) | Sports centres in residential units | For every 5000 population - 1 | 5000 square meters | ||
| 8. | Waste segregation space | Per 500 persons - 1 | 15 square meters | ||
| Public Toilet - WC seat | Per 50 persons -1 | 0.675 square meters (0.75x0.90) | |||
| Public Toilet - Urinal Unit | Per 200 to 300 persons -1 | 0.30 square meters (0,50x0.60) | |||
| City Bus Stop | Per 800 to 1000 m distance -1 | 50.40 square meters (3.6 x 14) | |||
| Foot Over Bridge | As per local requirement | ||||
| Vending Zone | Per 10000 persons -1 (500-1000 m distance) | 1000 square meters | |||
| Solid Waste Transfer Station | |||||
Note 1: The minimum plot area for the above-mentioned community facilities are indicative and governed by the norms prescribed from time to time by the concerned department.
Note 2: Areas earmarked for other services (such as police station / fire station etc.) if not used for 20 years, then it shall be returned back and converted to any other public use.
Note 3: For non-residential layouts, 5 percent area to be provided as common parking provision.
Note 4: For Education facilities, the provision of primary and nursery school can be included under high school/inter college, in view of which it will not be necessary to reserve a separate plot for each level of school as per the population standards.
Note 5: For Electric Sub-stations, in cases where depending upon the technology type of the sub-station, the requirement of the land is less than the prescribed standards prior consent of the concerned department shall have to be obtained.
Note 6: For Sports activities, the provision for neighbourhood sports centre and sports centre in residential units can be made within the area of proposed parks/open spaces at the layout plan level.
3.1.4.2 Population Estimation
The population shall be estimated on the basis of the standard of 5 persons for one residential unit (including group-housing/multi-units). Under plot development, population shall be estimated on the basis of 1 unit on a plot up to 50 square meters, 2 units on a plot of more than 50 and up to 150 square meters, 4 units on plots of area more than 150 and up to 300 square meters, one unit per 100 square meters but maximum 15 units on plots of area more than 300 square meters and up to 1500 square meters. This is only for estimation of population and shall not determine the number of units allowed on a particular plot size.