The Authority shall empanel structural engineers for peer reviewing/proof checking and certifying the design of buildings with height above 50 m, important service and community buildings or structures, lifeline and emergency buildings and/or large assembly buildings. The owner may also decide to carry
out proof checking of structural design for other buildings, provisions of IS 18299:2023 shall be adopted.
NOTE — Important service and community buildings or structures may include critical governance buildings, schools, signature buildings, monument buildings. Lifeline and emergency buildings may include hospitals, telecommunication buildings, bus stations, railway stations/buildings, airports, ports, food storage, power stations, fuel stations, fire stations, etc.
The peer reviewer/proof checker shall have the minimum qualification, experience, and competence as per IS 18299:2023:
The submission of the structural design by the structural engineer to the peer reviewer/proof checker shall be done in three stages as given below, and the succeeding stage submission shall be made only after obtaining concurrence for the preceding stage:
a) SDBR
b) Preliminary design, related drawings and documents
c) Detailed design, related drawings and documents