12.3.1 Buildings to be designed for Ambulant Disabled People
Higher Secondary School, Conference Hall, Dance Halls, Youth Centers, Youth Clubs, Sport Centers, Sport Pavilions, Boat Club Houses, Ice Rinks, Bowling Centers, Swimming Pools, Police Stations, Law Courts, Courts Houses, Sport Stadiums, Theaters, Concert Halls, Cinemas, Auditoria, Small Offices (the maximum plinth area 1400 sq.mt) Snack Bars, Cafes and banqueting rooms (for capacity above 50 dinners).
a. In sport stadiums provisions shall be made for non-ambulant spectators (small wheel chair)
b. @ 1:1000 up to 10,000 spectators and @ 1:2000 for spectators above 10,000.
c. In Theaters, Concert Halls, Cinemas and Auditoria provisions shall be made for non-ambulant spectators (Small Wheel Chairs) @ 1/250 up to 1000 spectators and 1/500 for spectators above 1000.
12.3.2 Buildings to be designed for Non-Ambulant Disabled People
Schools for differently abled and other buildings as mentioned in Sec 16, Chapter 1 and along with Botanical Gardens, Religious Buildings, Elderly People Clubs, Village Halls, Day Centers, Junior Training Centers, Post Offices, Banks, Dispensaries, Railway Stations, Shops, Super Markets, and Departmental Stores.
Note: Large wheel chair criteria shall be applicable on ground floors of the following building, post offices, banks, dispensaries, railway station, shops, supermarkets, and departmental stores.
12.3.3 Buildings to be designed for Non-Ambulant People (using small wheel chairs)
Public lavatories in Tourist Sports, Clubs Motels, Professional and Scientific Institution, Museum, Art Galleries, Public Libraries, Laborites, Universities, College for further Education, Teachers Training Colleges, Technical College, Exhibition Halls Dentist Surgeries, Administrative Department of the Hospitals, Service Stations, Car Parking, Buildings Airports Terminals, Bus Terminals, Factories Employing differently-abled for sedentary works, Large Offices, (with plinth area abode 1400 sq.mt.), Tax Offices, Passport Offices, Pension Offices, and Labour Offices, Cafes, Banqueting Rooms and Snack Bars (For capacity above 100 dinners)
12.3.4 Site development
Level of the roads, access paths and parking areas shall be described in the plan along with specification of the materials.
12.3.4.1 Access Path / Walk Way
Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm wide having even surface without any steps. Slope, if any, shall not have gradient greater than 5%. Selection of floor material shall be made suitably to attract or to guide visually impaired persons (limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emits different sound to guide visually impaired persons; hereinafter referred “o as "guiding floor material". Finishes shall have a non- slip surface with a texture traversable by a wheel chair. Kerbs wherever provided should blend to a common level.
12.3.4.2 Parking
For parking of vehicles of differently-abled people, the following provisions shall apply:
a. Surface parking for two car spaces shall be provided near entrance for the physically differently-abled persons with maximum travel distance of 30.0 m. from building entrance.
b. The width of parking bay shall be minimum 3.6 meter.
c. The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.
d. Guiding floor materials shall be provided or a device, which guides visually impaired persons with audible signals, or other devices, which serves the same purpose, shall be provided.