(i) In case of provision of stilts, Structural and soil bearing capacity certification and related plans prepared as per IS byelaws shall be furnished by the empanelled structural engineer. Stilts can be provided on any floor.
(ii) One stilt floor shall be excluded from the computation of F.A.R. and height of building only in case if the Internal unobstructed height of stilt(Ground floor to ceiling / level under the beam, whichever is lower) being maximum 2.40 mt. and being used only for parking and essential facilities. However, stilts shall be counted in height and FAR for computation of fire safety related norms.
(iii) In case a second stilt parking facility is provided in addition to the stilt floor on ground floor, it shall be computed in height and excluded in F.A.R computation.
(iv) Stilt parking shall be permissible which shall be open minimum from three sides and in case covered by wall / shutter / glazing towards the setback, it shall be treated as covered parking and shall be computed in the F.A.R. and in height.
(v) In small plots having area less than or equal to 200 sq. mt., to promote parking space, stilts can be constructed covered from all three sides provided the front is kept open and an affidavit is given by the owner that the stilt shall be used as parking only. In case the stilt is used for other purpose, the sanctioned plan will be cancelled.
7.3Basement and Basement Parking
Basement means a construction having a minimum 50 percent part of its height below the lowest ground level of the site. Depending upon the special topography of the site, it may be determined by the authority as per the definition in N.B.C-2016. The basement shall be used for parking, storage and utility
(1) Permissibility of Basement shall be as:
One Basement
More than One Basement
Hills
Single basement allowed in plots having minimum 18.0 mt. frontage as well as width AND minimum plot area 2000sq. mt.
not permitted
Plains
Upto plot size 750 sq. mt., 20% of the plot may be used for single basement meant for storage purpose and shall be accessible internally from building above
maximum three basements permitted in plots having 24 mt. frontage as well as width AND minimum plot area 4000sq. mt.
For plot size more than 750 sq. mt. single basement may be used for parking purposes
Table 10: Permissibility of Basement
(2) The basement may be put to following uses:
a. Parking
b. Storage of household or other goods of ordinarily non-combustible material;
c. Strong rooms, bank cellars, etc.;
d. Air-conditioning equipment and other machines used for services and utilities of the building.
e. Only in case of High Rise Buildings, up to 10% of basement may be utilized for utilities and non-habitation purpose like A/C Plant room, Generator room, Sewerage Treatment
Plant (STP), Electrical installations, Laundry, etc. This is allowed only after fulfilling the required parking spaces.
(3) The use of basement shall be specified in the building plans at the time of submission.
(4) The maximum expanse (ground coverage) of basement shall be 50% of the total plot area and shall be within the limits after leaving the required setback.
(5) Plots bearing dead setbacks as per norms shall be eligible to construct single basement provided minimum setbacks as stipulated below are provisioned instead of dead setback for the basement as well as for the superstructure. In other plots where setbacks are defined, the below tabulated or the defined setbacks, (whichever is more) shall be applicable.
S. No.
Height of the Building
Front Setback
Setback to be left on other sides
1
upto 9.0 mt.
3.6 mt
2.0 mt.
2
upto 12.0 mt.
4.5 mt
3.0 mt.
3
upto 15.0 mt.
4.5 mt
4.0 mt.
4
more than 15.0 mt.
4.5 mt
6.0 mt.
Table 11:Setbacks to be left based on height of the building for construction of basement
(6) The basement shall be admissible below the landscaped open areas with this restriction that the ceiling slab of basement shall not be more than ground floor (flushed with ground level and property landscaped as open / green space) and recharge borewells are provided adequately for ground water recharging. In case of podium construction, the green areas may be proposed over the podium with a condition that recharge borewells are provided adequately for ground water recharging.
(7) Provision of open ramp for access to the basement in setback area shall be permitted after leaving the requisite space for fire tender movement around the building [ie. 3.60 mt. and 6.0 mt respectively from low rise and high rise construction].
(8) The maximum travel distance from any point in basement shall be according the National Building Code.
(9) For basement, the Empanelled structural engineer shall furnish structural plans alongwith an affidavit regarding the suitability of the basement w.r.t bearing capacity of the soil, liquefaction and water table and the effect of excavation of basement on stability of neighboring buildings.
(10) The basement shall have the following provisions:
Light and ventilation of basement
a. An open area of a minimum width of 1.8 mt. shall be provided across the full length and / or width of the basement storey. This area shall be within the limits of the site and shall be paved with impervious material above a concrete bed. It shall be completely unobstructed except that in this area steps may be allowed for access to it, if considered necessary.
b. Basement storeys shall be lighted and ventilated by means of windows of the minimum area within 1 / 10th to 1 / 25th of the total floor area, at least half of which must open subject to the condition that the deficit of light and ventilation shall be made up by providing artificial lighting and mechanical ventilation as per provision of National Building Code of India.
c. In the second basement and basement below the lower ground floor where it is to be used for parking / services, the provisions contained in National Building Code and Fire Safety Byelaws as applicable shall be followed.
d. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air-conditioning systems, etc.
(ii) Damp proofing of Basement
The walls of the basement storey shall be properly damp proofed and if in contact with the soil, they must be effectively secured against dampness from the soil with the approved vertical and horizontal damp proof course.
(iii) Height of the Basement
a. The minimum clear height of the basement shall be 2.4 mt. and maximum clear height of the basement shall be up to 4.75 mt.from floor to the underside of the roof slab or ceiling subject to structural stability to be certified by the Structural Engineer.
b. The minimum height of the roof of basement shall be 0.9 mt. and maximum 1.20mt. above the average surrounding ground level for plots upto 1000 sq. mt.
c. For plots above 1000 sq. mt., the roof of basement shall be either flushed with ground or the maximum height shall be 1.20 mt. above the average surrounding ground level.
(iv) Drainage of Basement
a. Open area adjoining a basement storey, if any, shall be effectively drained to the satisfaction of the Competent Authority.
b. The responsibility of draining a basement storey and for protecting it from rain shall be that of the owner.
c. The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors.
d. Where the staircase is continuous in the case of buildings served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors.
e. The “Exit” requirements in basements shall comply with the provisions ofPart 4 ‘Fire and Life Safety’ of National Building Code of India.
Chapter 7Building Design Norms
7.1 Parking
(1) Computation of parking areas
(i) Based upon the type of parking, the Equivalent Car Space [ECS] norms shall be as follows which is inclusive of the circulation space and ramp.
a. Open area Parking / Terrace parking on road level: 23 sq. mt.
b. Covered parking / stilt parking:28 sq. mt.
c. Basement / *terrace / * subsequent floors of ground floor: 32 sq. mt.
d. Fully mechanized parking in the basement / *terrace / * subsequent floor of ground floor: 16 sq.mt. or as per standard design for such parking
e. Stack parking / double decker parking: In case of provision of mechanical slot the E.C.S. of the floor on which stack parking is proposed shall be according to the type of floor viz; basement, terrace, stilt and open space as the case may be and in subsequent slots it shall be minimum 16sq. mt. per ECS.
For example, stack parking / double decker parking in non-mechanized parking in basement of 1000 sq. mt. area.
ECS of basic floor = 1000 / 32=31 ECS
ECS in subsequent slots = 1000 / 16=62 ECS
Total ECS that can be accommodated in this basement = 31+62= 93ECS
f. The minimum area for equivalent car space for residential (plotted) development shall be 13.75 sq.mt. per plot.
*Terrace parking / parking on subsequent floor of ground floor, shall be permissible only in plots having total minimum plot area 1000 sq. mt.(one side of plot must be minimum 25 mt. wide). Terrace parking on road level / on terrace can be covered by shed whose sides shall remain open.
(ii) As an alternative to above E.C.S. provisions, the provision of ‘parking bay’ shall be permissible by considering a ‘parking bay’ of 2.75 mt.X 5.0 mt. equivalent to an E.C.S with the condition that proper approach / driveway / aisle / circulation is available for parking bay slots as per design standard.
(iii) The ramp to basement and parking floors shall not be less than 7.2mt. wide for two way traffic and 4.2 mt. wide for one way traffic, with gradient not steeper than 1:10.
(2) Parking Norms
The norms for parking in the respective plots for building of different occupancy shall be as under. In hill area these norms shall be 25 percent less than from the norms prescribed here:
Occupancy Building
Parking Space
For Single Housing unit
ECS
a
On 100-200 sq.mt. floor area
One parking place of 13.5 sq.mt. (5.0 mt. x 2.75 mt.) 1.00 ECS
b
On floor area above 200sq., mt.
1.00 ECS on per 100 sq.mt. covered area or part thereof
Occupancy of Building
Parking Space on per 100sq.mt. covered area or part
For Multiple Residential Unit
1.00 ECS
Group Housing
On each unit of 50-75 sq.mt. floor Area
1.00 ECS
On each unit of 75-150 sq.mt. floor area
1.25 ECS
On each unit above 150 sq.mt. floor Area
1.50 ECS
Commercial Use
On plots of upto 50 sq.mt.
--
On plots of upto 250 sq.mt.
1.00 ECS
On plots above 250 upto 500 sq.mt.
1.50 ECS
On plots of above 500 to 1500 sq.mt.
2.00 ECS
On plots of above 1500 sq.mt.
2.50 ECS
Wholesale market- Freight Complex
3.50 ECS
Mall, Multiplex - Multiplex- Commercial, mixed use / Cinema hall
3.50 ECS
Hotel
2.50 ECS
Lodging / Tourist home / Musafirkhana / Dharamshala / Guest house / Resort / stand-alone private Hostel
1.50 ECS
Hostels inside educational institutions
0.75 ECS
Community hall / Auditorium
2.00 ECS
Ashram, Cultural or Social institution
1.50 ECS
Nursing home / Primary health center / hospital
2.00 ECS
Wedding Point
30 percent of total area of scheme or parking space on the basis of per 100 sq.mt. covered area or part thereof, whichever is more
Office, Court, other Offices
2.50 ECS
Primary, Middle School, High School / Inter College
1.25 ECS
Degree College, University, High Standard / Technical Educational Institutes
1.50 ECS
Information Technology Campus and Unit under related unit
2.00 ECS
Industry
Domestic / Services / Small industry
0.60 ECS
Other industry
0.75 ECS
Godown, Cold Storage
1.00 ECS
Stadium (one ECS on 20 seats)
-
Amusement park / other entertainment place / exhibition place (3.0 percent of total area of scheme)
-
Other Community Hall
1.50 ECS
Table 20: Parking Space Requirement based on type of occupancy of building
(3) Other miscellaneous provisions for parking
(i) Minimum 25 percent of total parking shall be required to be provisioned as open parking for group housing.
(ii) In all building/uses except single residential and multiple units, parking shall not be permissible in setback area and in case of group housing parking shall be permissible in maximum 25 percent area of the setback after leaving a regular shaped pathway of minimum width 3.60 mt. and 6.0 mt respectively from low rise and high rise construction.
(iii) In schemes of one acre and above area, in case a multi-level parking block is constructed, a ground coverage of 5 percent more than the prescribed shall be permissible under building envelope, which will be used for parking only. The said 5 percent shall not be included in F.A.R. However, the footprint of separate parking building blocks shall be counted towards ground coverage.
(iv) The plan of parking proposal shall also be submitted with the plans of high rise building proposed for group housing and non-residential purpose and the parking plan shall be shown along with the provision of circulation / ramp for their proper entry and exit.
(v) The covered parking in the basement or in the form of stilt above ground level shall not be counted towards Floor Area Ratio (FAR).
(vi) In case of provision of stack parking in the basement floor / upper stories, the floor to ceiling clear height of the basement / floor may be maximum of 4.75 mt.
(vii) No storage and commercial activities shall be permitted in the covered parking areas.
7.6Minimum Area, Size and Height in Residential Premises
Minimum area for a habitable room, kitchen and water closet shall be followed in accordance to table given as under:
S. No.
Components of Building
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
S. No.
Components of Building
Area (sq. mt.)
Width (m)
Height (m)
Area (sq. mt.)
Width (m)
Height (m)
1
Habitable Rooms
7.5
2.1
2.75
9.5
2.4
2.75
2
Kitchen
3.3
1.8
2.75
4.5
1.8
2.75
3
Pantry
-
-
-
3.0
1.4
2.75
4
Kitchen with Dining area
7.5
2.1
2.75
7.5
2.1
2.75
5
Bathroom
1.2
1.0
2.2
1.8
1.2
2.2
6
w.c.
1.0
0.9
2.2
1.2
0.9
2.2
7
Combined Bath
1.8
1.0
2.2
2.8
1.2
2.2
S. No.
Components of Building
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit up to 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
Minimum Requirement for a Dwelling Unit above 50 sq. mt.
&w.c.
8
Door ways
-
0.9
2.1
-
0.9
2.1
(Habitable rooms)
(Kitchen, Bath, w.c.)
-
0.75
2.0
-
0.75
2.0
9
Staircases
-
1.0
-
-
1.0
-
11
Store room
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sq. mt. and above, the light and ventilation clause shall also apply.
12
Projections
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary
Table 123: Minimum Requirements of a dwelling unit
Note: *In case of air conditioned rooms, the height shall not be less than 2.4 mt.measured from the surface of the floor to the lowest point of air conditioning duct or false ceiling; and
For educational and industrial buildings, the following minimum requirements apply :
a) Educational : Ceiling height 3.6 m for buildings all regions; in cold regions, 3 m
b) Industrial : small factories with workforce upto 50 :Ceiling height 3.6 m, buildings conditioned, 3 m (Factory Act, 1948 and rules therein shall govern such heights, where applicable). in large factories the minimum internal height of workrooms shall not be less than 4.5 m. measured from the floor level to the lowest point in the ceiling
7.4Courtyard
(i) The courtyard shall have a minimum area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard. Provided that when any room (excluding staircase bay, bathroom and water-closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(ii) Provided that such courtyard shall not be less than 12.0 sq. mt. in area and the minimum width of every such courtyard in any direction shall not be less than 3.0 mt.
(iii) The area of the courtyard for the purposes of these Byelaws shall be the area open to sky, clear of all projections.
7.5 Plinth
(i) The plinth of the main building shall be so located with respect to surrounding ground level that proper drainage of the site is assured. The height of the plinth shall not be less than 450 mm (0.45 mt.).
(ii) In no case, any part of the ramp / steps connecting building plinth to street / roadshall lie on street / road and obstruct traffic movement. However, the ramp / step from the plot boundary to the entry of house building, if required shall be provided.
7.7Boundary Wall, Fence, Gate and Porch
(1) Maximum permissible height of front side boundary wall shall be not more than 1.2 mt.from the mean level of abutting street in front of the plot from where entry to the plot has been taken. In case of hills, boundary wall shall be as above or shall not be more than 1.2 mt. from the higher side ground level of retaining wall
Note: The owner / applicant if desires, is permitted to not construct boundary wall in front of plot, so that the said area can be utilized for parking.
(2) Maximum height of boundary wall at rear and side of plot shall not be more than 1.8 mt.from the mean level of abutting street in front of the plot from where entry to the plot has been taken.
(3) A railing / grill with or without poly carbonate / fiber glass sheet covering of 0.75 mt. height shall be permitted over and above the maximum height of boundary wall at all sides.
(4) The temporary porches of polycarbonate sheets / fiber glass roof or any other temporary material covering on suitable structure, shall be allowed in residential plots with the condition that these shall be open on sides in the driveway area within the plot.
(5) The above provisions are not applicable to boundary walls of jails and other such buildings of security importance.
(6) Boundary wall upto the height of 2.4 mt. may be permitted by the Competent Authority in industrial buildings, electric sub-stations, transformer stations, institutional buildings like hospitals, industrial buildings like workshops, factories and educational buildings like schools, colleges, including hostels and other uses of public utility undertakings and strategically sensitive buildings.
(7) In case of corner buildings the height of boundary wall shall be restricted to 0.75m for length of 10m on the front and side of the inter-sections and the balance height of 0.75m if required may be constructed with the perforated stone jali / iron grills / vegetation) to maintain visual continuity
7.8Staircase Requirements
(i) For buildings such as assembly, business, education, hazardous, industrial, institutional, Mercantile Building, High Rise Building, Multi-Level Car Parking Building, Office Building (premises), Special Building, Storage Buildings and Wholesale Establishment, there shall be minimum of two staircases and one of them may be enclosed stairway and the other shall be on the external walls of building and shall open directly to the exterior, interior open space or to any open place of safety.
(ii) Single staircase may be considered for Non-high-rise residential, educational, business or group housing society where single floor area does not exceed 500 sq. mt. and height of the building does not exceed 12mt. and other requirements of occupant load travel distance and width of staircase shall meet the requirement. these staircase shall be in the form of interior stairs as mentioned in 7.8 (4)
(iii) Every building intended to be used as multiple residential building or commercial or educational and institutional or industrial building shall be provided with required number of staircases (accessible from a maximum distance of 30 mt. (45 mt., if building has automatic sprinklers for fire-fighting) from any part of the building, extending from ground floor level to the highest floor:
(iv) Stairways
a. Interior stairs shall be constructed of non-combustible material throughout.
b. Interior stairs shall be constructed as a self-contained unit with at least one side adjacent to an external wall and shall be completely enclosed unless mechanically ventilated.
c. A staircase shall not be arranged round a lift shaft for buildings above 7.5 mt.height. The staircase location shall be to the satisfaction of department of Fire Services.
d. Hollow combustible construction shall not be permitted.
e. The minimum width of internal staircase shall be as per the following table
S. No.
Type of Building
Minimum width for each stairway(mt.)
1
Residential Non High Rise Buildings
1.00
2
Other Residential Buildings e.g. Apartments, Hostels, Group Housing, Guest Houses, etc.
1.25
3
Educational Buildings like Schools, Colleges
1.50
4
All other buildings including Hotels, Nursing Homes etc.
1.50
5
Institutional Buildings like Hospitals etc.
2.00
6
Assembly Buildings like Auditoria, Theatres and Cinemas
2.00
Table 13: Minimum Width Provisions for Stairways
f. The minimum width of treads without nosing shall be 25cm for an internal staircase for residential buildings. In the case of other buildings, the minimum tread shall be 30cmt. The treads shall be constructed and maintained in a manner to prevent slipping. Winders shall be allowed in residential buildings provided they are not at the head of a downward flight.
g. The maximum height of riser shall be 19cm in the case of residential buildings and 15cm in the case of other buildings and these shall be limited to 12 per flight.
h. Handrails shall be provided with a minimum height of 90cm from the center of the tread.
i. The minimum headroom in a passage under the landing of a staircase and under the staircase shall be 2.2 mt.
j. For building more than 24m in height, access to main staircase shall be through a lobby created by double door of half an hour fire rating. One of the doors will be fixed in the wall of the staircase and other after the lobby.
k. No living space, store or other fire risk shall open directly into the staircase or staircases.
l. External exit door of staircase enclosure at ground level shall open directly to the open spaces or can be reached without passing through any door other than a door provided to form a draught lobby.
m. The main staircase and fire escape staircase shall be continuous from ground floor to the terrace level.
n. No electrical shafts / AC ducts or gas pipe etc. shall pass through the staircase.
o. Lift shall not open in staircase landing.
p. No combustible material shall be used for decoration / wall paneling in the staircase.
q. Beams / columns and other building features shall not reduce the head room / width of the staircase.
r. The exit sign with arrow indicating the way to the escape route shall be provided at a suitable height from the floor level on the wall and shall be illuminated by electric light or
glow sign or florescent connected to corridor circuits. All exit way marking sign should be flush with the wall and so designed that no mechanical damage shall occur to them due to moving of furniture or other heavy equipment’s. Further all landings of floor shall have floor-indicating boards indicating the number of floor as per Building Regulations. The floor indication board shall be placed on the wall immediately facing the flight of stairs and nearest to the landing. It shall be of size not less than 0.2mt.x 0.5mt.
s. Individual floors shall be prominently indicated on the wall facing the staircase.
t. In case of single staircase it shall terminate at the ground floor level and the access to the basement shall be by a separate staircase. However, the second staircase may lead to basement levels provided the same is separated at ground level either by ventilated lobby with discharge points at two different ends through enclosures.
u. Any staircase made for use of Fire escape which will be open to sky (can be covered from top but sides shall be open) will not be considered under FAR calculation.
(v) Spiral Stairs (fire escape)
a. The use of spiral staircase shall be limited to low occupant load and to a building height of 9mt. provision of landing shall be made after very 3.0 mt or part thereof.
b. A spiral stairs shall not be less than 150 cm. in diameter and shall be designed to give the adequate headroom.
7.9Fire Escape Staircases
(i) Fire escape shall not be taken into account while calculating the number of staircases for a building.
All fire escapes shall be directly connected to the ground.
(iii) Entrance to the fire escape shall be separate and remote from internal staircase.
(iv) The route to fire escape shall be free of obstructions at all times except the doorway leading to the fire escape which shall have the required fire resistance.
(v) Fire escape shall be constructed of non-combustible materials.
(vi) Fire escape stairs shall have straight flight not less than 125cm. wide with 25cm. treads and risers not more than 19cm. and the number of risers shall be limited to 16 per flight.
(vii) Handrails shall be at a height not less than 100cm.
(viii) Fire escape staircase in the mercantile, business, assembly, hotel buildings above 24mt. height shall be a fire tower and in such a case width of the same shall not be less than the width of the main staircase. No combustible material shall be allowed in the fire tower.
(ix) Fire escape staircase shall not be in the form of spiral staircase.
7.10 Minimum Width Provisions for Passageway / Corridors
The following minimum width provisions shall be made for each passageway / corridor:
S. No.
Type of Building
Minimum Width (mt.)
1
Individual Residential buildings
upto 7.5 mt height
---
1.00
above 7.5 mt height
2
Other Residential buildings, e.g. Hostels, Group Housing etc.
upto 12.0 mt height
1.25
above 12.0 mt height
1.50
3
All Other Buildings including Hotels
2.00
4
Assembly Buildings like Auditoria, Theatres and Cinemas
2.50
5
Hospital, Nursing Homes, etc.
2.50
Table 25: Minimum Width Provisions for Passageway / Corridors
7.11Ramps and Lifts
(1) Every building having more than 12mt. height shall be provided with a lift or a ramp with an inclination of 1:10 in addition to the staircases. In all residential building having more than15mt.height,is mandatory to install lift and number of lifts depending upon the occupancy of building.
(2) In case of public building with only ground floor, ramp shall be provided for reaching its plinth level. Further, in case of public building is more than one storey, lift or ramp shall be provided.
(3) Ramps:
a. The ramp to basement and parking floors shall not be less than 7.2 mt. wide for two way traffic and 4.2 mt. wide for one way traffic, provided with minimum gradient of 1:10. At curved portions of the ramp or for circular ramps the slope should not be more than 1:12.
b. The minimum width of the ramps in hospitals shall be 2.4 mt. for movement of stretcher and for public use. In no case, the hospital ramps shall be used for vehicular movement, except at entry gate to the building.
c. Pedestrian Ramp: Minimum width of ramp shall be 1800mm with maximum gradient 1:12. Ramp shall be finished with non-slip material to enter the building.
d. All structural design / safety aspects as per latest Bureau of Indian Standards Byelaws and National Building Code, (as amended from time to time) shall be complied along with consideration of weight of Fire Engine & its maneuvering.
e. A ramp shall have handrail on at least one side, and preferably two sides with minimum height of 0.90 mt., measured from the surface of the ramp. The handrails shall be smooth and extend to 0.30 mt. beyond the top and bottom of the ramp. Where major traffic is predominantly children, the extra handrail shall be placed 0.76 mt. height.
(4) Lifts:
a. Wherever lift is required as per Byelaws, provision of at least one lift shall be made for the wheel chair users, with the following cage dimensions, recommended for passenger lift of 13 persons capacity by the Bureau of Indian Standards:
Clear internal depth 1.1 mt.
Clear internal width 2.0 mt.
Entrance door width 0.9 mt.
b. A handrail not less than 0.6 mt. long and 1 mt. above floor level shall be fixed adjacent to the control panel.
c. The minimum size of lift lobby shall be 1.8 mt. x 2.0 mt. or more.
d. The interior of the cage shall be provided with Braille symbols and auditor signage that audibly indicates the floor. When the cage reached on floor, itshall indicate that the door of the cage for entrance / exit is either open or closed.
7.12Exit
(i) The requisite number and size of various exits shall be provided, based on the occupants in each room and floor based on the occupant load, capacity of exits, travel distance and height of buildings as per provisions of Part 4- Fire and Life Safety, National Building Code as amended from time to time.
(ii) At least one primary entrance and exit to each building shall be usable by individuals in wheelchairs, indicated by a sign and on a level that would make the elevators accessible.
(iii) Arrangement of Exits
a. Exits shall be so located so that the travel distance on the floor shall not exceed 22.50 mt. for residential, educational, institutional and hazardous occupancies and 30.0 mt. for assembly, business, mercantile, industrial and storage occupancies. Whenever more than one exit is required for a floor of a building they shall be placed as remote from each other as possible. All the exits shall be accessible from the entire floor area at all floor levels.
b. The travel distance to an exit from the remote point shall not exceed half the distance as stated above.
Note: Provided for fully sprinkled building, the travel distance may beincreased by 50 percent of the values specified.
(iv) Width of Exit
a. No exit doorways shall be less than 1 mt. in width except assembly and institutional buildings where it shall not be less than 2 mt.
b. Exit doors shall open outwards, that is away from the room but shall not obstruct the travel along any exit. No door when opened shall reduce the required width of stairway or landing to less than 0.90 mt. Overhead doorshall not be installed.
7.13Means of Access
(i) No Building shall be erected as to deprive any other building of its means of access.
(ii) If there are any bends or curves in the approach road, sufficient width shall be permitted at the curve to enable the fire tenders to turn, the turning circle shall be at least of 9.0 mt. radius.
(iii) Other provisions of means of access for buildings other than plotted residential and commercial:
a. The approach to the building and open spaces on its all sides, shall have composition of hard surface capable of taking the weight of fire tender, weighing upto 22 tonnes for low rise building and 45 tonnes for building 15 mt. and above in height. The said open space shall be kept free of obstructions and shall be motor-able.
b. Main entrance to the premises shall be of adequate width to allow easy access to the fire tender and in no case it shall measure less than 6.0 mt. The entrance gate shall fold / slide back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of the fire service vehicles. If archway is provided over the main entrance, the height of the archway shall not be of height less than 5.0 mt.
c. In case of basement extending beyond the building line, it shall be capable of taking load of 45 tonnes for a building of height 15.0 mt. and above and 22 tonnes for building height less than 15.0 mt.
(iv) Every person who applies for permission for erection or re-erection of building shall also submit NOC for accessing the road (whether National Highway, State Highway) if applicable from the concerned authority.
7.18Solid Waste Management
(i) Before sanctioning any kind of project, except single dwelling unit (but including layout / sub division projects), the sanctioning authority shall ensure that adequate provisions pertaining to solid waste disposal / segregation at the source / storage has been shown in the plan. The following three bins shall be indicated:
a. Bio - degradable
b. Non – bio-degradable
c. Domestic hazardous waste
(ii) Minimum five percent at the total area of industrial estates / park will be ear marked in the map for recovery and recycling facility.
(iii) All types of medical facilities like hospitals, Nursing Home, Pharmacy, Pathology Lab etc., shall obtain an affidavit from Uttarakhand State Environment and Pollution Control stating the compliance of Bio Medical Waste Regulations, 2016.
(iv) The applicant shall furnish an affidavit that the waste generated from the construction and demolition of the proposed constructions, shall be disposed of as per the construction and demolition waste regulations 2016.
7.17Services
(i) The water supply and drainage, design, construction and installation shall be made according the prescribed standard in Part IX of the National Building Code of India. The planning of electricity provisions, Air conditioning,mechanical ventilation, Lift etc. shall be ensured according
the part VIII of the National building Code of India. The planning of sanitation system shall be ensured according to Annexure-4
(ii) Service Floor - For specialized buildings such as hospitals, hotels, commercial complexes, in which service ducts are required for HVAC and other pipelines, a service floor of maximum clear height (including beam) 1.80 mt. may be permitted which shall not be counted towards FAR and height of the building. More than one service floor shall be counted towards height of the building.
7.14Light and Ventilation of building
(i) Every room that is intended for human habitation shall abut on an interior or exterior open space or on to a verandah open to such interior or exterior open space.
(ii) The setback area can be sunk for light, ventilation and access to basement, provided fire tender movement is not hindered.
(iii) Sunken courtyard up to the lowest floor of basement(s) shall be allowed as ‘light well’ within building envelop for light and ventilation for basement area.
(iv) Other provisions of light and ventilation for buildings other than plotted residential and commercial:
(v) Ventilation shaft: For ventilating the spaces for water closets and bathrooms, if not opening on the front side, rear and interior open spaces, shall open on the ventilation shaft, thesize of which shall not be less than the values given below:
Sr. No.
Height of Building (mt.)
MinimumsizeofVentilation Shaft (sq. mt.)
Minimumwidthof Shaft (mt.)
1.
Upto 10.0
1.2
0.9
2.
Upto 12.0
2.8
1.2
3.
Upto 18.0
4.0
1.5
4.
Upto 24.0
5.4
1.8
5.
Upto 30.0
8.0
2.4
6.
Above 30.0
9.0
3.0
Table 14: Requirements for Ventilation Shaft
For fully air-conditioned buildings the ventilation shaft shall not be required, provided the airconditioning system works on uninterrupted source of power supply.
Horizontal ducting for ventilation may be installed in building with exhaust fan of appropriate capacity for discharging used air to external face of building.
7.15Cantilevered Roof and Chajja Projections
(i) No building verandah, chajja or other projections from the face of the building shall be allowed to be erected or re-erected on or over a road or beyond the boundaries of the applicants own land / plot.
(ii) Balcony of a width of maximum 1.80 mt. in front and rear sides of a plot can be permitted within the plot, provided the width of balcony do not exceed half of the width of setback.
(iii) Sun-shades over opening shall be allowed subject to the following:
a. Sun-shade if provided, shall be at a height of 2.3 mt. from the ground level shall be permitted to project up to a maximum of 0.45 mt. within the applicants own land, provided it does not exceed half of the width of setback / open space.
7.16 Mezzanine floor
(i) A mezzanine floor shall not cover more than 1 / 2 of the room area and the minimum area shall be 6.5 sq.mt. The area of such mezzanine floor shall be counted towards FAR.
(ii) The clear height of such mezzanine floor and the floor below it shall not be less than 2.2 mt. from the floor level to the soffit of ceiling.