(i) In case of provision of stilts, Structural and soil bearing capacity certification and related plans prepared as per IS byelaws shall be furnished by the empanelled structural engineer. Stilts can be provided on any floor.
(ii) One stilt floor shall be excluded from the computation of F.A.R. and height of building only in case if the Internal unobstructed height of stilt(Ground floor to ceiling / level under the beam, whichever is lower) being maximum 2.40 mt. and being used only for parking and essential facilities. However, stilts shall be counted in height and FAR for computation of fire safety related norms.
(iii) In case a second stilt parking facility is provided in addition to the stilt floor on ground floor, it shall be computed in height and excluded in F.A.R computation.
(iv) Stilt parking shall be permissible which shall be open minimum from three sides and in case covered by wall / shutter / glazing towards the setback, it shall be treated as covered parking and shall be computed in the F.A.R. and in height.
(v) In small plots having area less than or equal to 200 sq. mt., to promote parking space, stilts can be constructed covered from all three sides provided the front is kept open and an affidavit is given by the owner that the stilt shall be used as parking only. In case the stilt is used for other purpose, the sanctioned plan will be cancelled.