11.1 Core Built Up Area
(i) Built up Zones / core built-up areas are normally defined in the Master Plans. In areas where such zones are not defined in the Master Plans or where Master Plans are not in force, core built up area / Zones in Development Area will be defined by the concerned Department Authorities and by Town and Country Planning Department outside the Development Area of the state.
(ii) Residential and Commercial activities or such activities which are permissible as per zoning regulations will be permitted and following activities will not be permitted.
a. Motel and resorts, multiplex and malls, multistory commercial complex (more than two floor).
b. Offices (except offices of maximum 200 sq. mt. floor area)
c. College, ITI / Poly technique, miscellaneous Technical Colleges, university complex.
d. Hospital, higher / specialized medical facilities.
e. Auditorium, Town Hall, vocational and technical institutions, cinema / theatre, coal Depot, filling and service station.
f. Industrial Units (except such Household units of maximum 30 sq. mt. area) less than 5 Kw capacity employing a maximum of 5 workers.
(iii) Norm for Development and Redevelopment / Reconstructions
a. Minimum Net Plot Area 30 sq. mt. (Residential)&10 sq. mt. (Commercial) Minimum Width 2.0 m (Commercial Plot) Width of Residential Plot as per definition of Housings (EWS,LIG.LMIG) and Plot GIVEN in definitions. In the towns of religious importance the minimum net plot area of guest house shall be 250 sq. mt. in hills and 400 sq. mt. in plains.
b. Front Boundary:
In case where the road is not a Master Plan road the front boundary of the plot will be determined from the center line of the road abutting the plot. The determination of such boundary will be as follows:
| S. No. | Existing Road Width | Distance to be left from the centre of the existing road for determination of front boundary | Maximum Height of the buildings |
|---|---|---|---|
| 1 | Up to 3.0m | 1.5m | 6.5m |
| 2 | 3.1 to 4.5 m | 2.25m | 6.5m |
| 3 | 4.6 to 7.5m | 3.75m | 9.0m |
| 4 | 7.6 to 9.0m | 4.5m | 9.0m |
| 5 | 9.1 to12.0m | 6.0m | 12.0m |
| 6 | 12.1 to 18.0m | 9.0m | 12.0m |
Table 19: Determination of Front Boundary
In towns of religious importance, the approach road provisions for guest house shall be as follows:
| Region | Min approach road existing width | Road widening to be left fully from the plot |
| Hills | 4.5 mt. | Min 1.5 mt. |
| Plains | 7.50 mt. | 1.5mt. |
| Parking if not available within the plot, the same shall be provided within 500mt. from the site at public parking place and the same shall be ensured by the sanctioning authority. | ||
Table 20: Approach road provisions for guest house
c. Norm for Reconstruction of Building in plots upto 200sq. mt.
| S. No. | Building Norm | Norm as per Plot size | |
| Upto 100 sq. mt. | (>100-200 sq. mt.) | ||
| 1 | Ground coverage | 75% | 70% |
| 2 | FAR | As per Permissible ground coverage and permissible maximum height | |
| 3 | Minimum front setback* | 1.20 | 1.80 |
| 4 | Basement | not allowed | not allowed |
Table 21: Norm for Reconstruction of Building in plots upto 200 sq. mt.
Note: *Existing setback will prevail in cases where the existing setback are greater than the above mentioned setbacks.
(iv) For Plots upto 200 sq. mt. Plot Area and abutting on a minimum of 9.0 m width road maximum 20% of the permissible Ground coverage can be used as basement in Commercial / Mixed Buildings. Such basement will be used only for storage.
The approach to such Basement will be in the form of internal staircase / ramp.
(v) For Corner Plot of upto 100 sq. mt. Area the provision of road side setback on sides and rear will not be mandatory. Such plots having an area of 101 sq. mt. to 200 sq. mt., a minimum of 1.0
mt. road side setback is required. In case where the existing setback is greater than the required setback the provision existing of setback will prevail.
(vi) For plots greater than 200 sq. mt. Area provision of ground coverage, FAR, minimum front setback and basement will be as per the respective provisions of the byelaws. Basement will not be permissible in Residential / mixed use Building and in Building abutting on roads less than 9.0 m width.
(vii) Sub division of Plots will be as per sub division bylaws and with a minimum Area of such sub divided plots shall be 40 sq. mt.
(viii) For non-residential use building on roads less than 9.0 mt. or plot size less than 200 sq. mt. public parking shall be developed by the sanctioning authority. For this purpose parking fee shall be charged at the time of sanctioning plan which shall be computed based upon the circle rate of the required parking area in the project. This fee shall be deposited in an ESCROW account for parking fund and shall be used exclusively for developing public parking spaces in or near core areas.
(ix) A maximum of 40% width of front setback (front setbacks to be determined after having the required Right of way of public roads) can be used for sunshade, projection, Balcony etc.
(x) Plinth Level: minimum 0.45 mts. from ground level.
(xi) Horizontal and vertical expansion will be permitted subject to the structural safety of such building. The expansion will be permitted in cases where the required right of way and setback condition are adhered to. Such expansion will be permitted within the FAR limits.
11.2 Single Residential
(i) Normally, in open / undeveloped areas, individual single residential units will bepermitted only if the sub divided plot is part of a larger approved layout plot.
(ii) However, in special circumstances, after due permission from the sanctioning authority, such stand-alone plots situated within the urban local body limits, which have not been sub divided from a larger open area and where the width of the road is less than the required width, permission for construction can be granted after leaving required land for right of way to ensure minimum road width and required setback.