2.1 For the purpose of this Section, the following definitions shall apply.
2.1.1 Accessory — A device, other than current using equipment, associated with such equipment or with the wiring on an installation.
5
2.1.2 Apparatus — Electrical apparatus including all machines, appliances and fittings in which conductors are used or of which they form a part.
2.1.3 Appliance — An item of current using equipment other than a luminaire or an independent motor.
2.1.4 Bunched — Cables are said to be ‘bunched when two or more are contained within a single conduit, duct, ducting, or trunking or, if not enclosed, are not separated from each other.
2.1.5 Cable — A length of single-insulated conductor (solid or stranded), or two or more such conductors, each provided with its own insulation, which are laid up together. The insulated conductor or conductors may or may not be provided with an overall mechanical protective covering.
2.1.6 Cable, Armoured — A cable provided with a wrapping of metal (usually in the form of tape or wire) serving as a mechanical protection.
2.1.7 Cable, Flexible — A cable containing one or more cores, each formed of a group of wires, the diameters of the cores and of the wires being sufficiently small to afford flexibility.
2.1.8 Cable, Metal-Sheathed — An insulated cable with a metal sheath.
2.1.9 Cable, PVC Sheathed-Insulated — A cable in which the insulation of the conductor is a polyvinylchloride (PVC) compound; with PVC sheath also providing mechanical protection to the conductor core or cores in the cable.
2.1.10 Cable, Weatherproof — A cable so constructed
that when installed in uncovered locations, it will withstand all kinds of weather variations (see 2.1.80, for definition of Weatherproofing).
2.1.11 Cable, XLPE — A cable in which the insulation of the conductor is cross-linked polythene and the mechanical protection is provided for the core or cores by a sheath of a poly vinyl chloride compound.
2.1.12 Ceiling Rose — A fitting (usually used to attach to the ceiling) designed for the connection between the electrical installation wiring and a flexible cord (which is in turn connected to a lampholder).
2.1.13 Circuit — An assembly of electrical equipment supplied from the same origin and protected against overcurrent by the same protective device(s). Certain types of circuit are categorized as follows:
a) Category 1 Circuit — A circuit (other than a fire alarm or emergency lighting circuit) operating at low voltage and supplied directly from a mains supply system.
b) Category 2 Circuit — With the exception of fire alarm and emergency lighting circuits, any circuit for telecommunication (for example, radio, telephone, sound distribution, intruder alarm, bell and call and data transmission circuits) which is supplied from a safety source.
c) Category 3 Circuit — A fire alarm circuit or an emergency lighting circuit.
2.1.14 Circuit Breaker — A mechanical switching device capable of making, carrying and breaking currents under normal circuit conditions and also of making, carrying for a specified time, and breaking currents under specified abnormal circuit conditions such as those of short circuit.
NOTE — A circuit breaker is usually intended to operate in frequently, although some types are suitable for frequent operation.
2.1.15 Circuit, Final Sub — An outgoing circuit connected to one-way distribution board and intended to supply electrical energy at one or more points to current, using appliances without the intervention of a further distribution board other than a one-way board. It includes all branches and extensions derived from that particular way in the board.
2.1.16 Cleat — An insulated incombustible support normally used for insulated cable.
2.1.17 Conductor, Aerial — Any conductor which is
supported by insulators above the ground and is directly exposed to the weather.
NOTE — Four classes of aerial conductors are recognized:
a) Bare aerial conductors,
b) Covered aerial conductors,
c) Insulated aerial conductors, and
d) Weatherproof neutral-screened cable.
2.1.18 Conductor, Bare — A conductor not covered with insulating material.
2.1.19 Conductor, Earthed — A conductor with no provision for its insulation from earth.
2.1.20 Conductor, Insulated — A conductor adequately covered with insulating material of such quality and thickness as to prevent danger.
2.1.21 Conductor of a Cable or Core — The conducting portion consisting of a single wire or group of wires, assembled together and in contact with each other or connected in parallel.
2.1.22 Connector — The part of a cable coupler or of an appliance coupler which is provided with female contact and is intended to be attached to the flexible cable connected to the supply.
2.1.23 Connector Box or Joint Box — A box forming a part of wiring installation, provided to contain joints in the conductors of cables of the installations.
2.1.24 Connector for Portable Appliances — A combination of a plug and socket arranged for attachment to a portable electrical appliance or to a flexible cord.
2.1.25 Consumer’s Terminals — The ends of the electrical conductors situated upon any consumer’s premises and belonging to him at which the supply of energy is delivered from the service line.
2.1.26 Cord, Flexible — A flexible cable having conductor of small cross-sectional area. Two flexible cords twisted together are known as twin ‘flexible cord’.
2.1.27 Core of a Cable — A single conductor of a cable with its insulation but not including any mechanical protective covering.
2.1.28 Cut-out — Any appliance for automatically interrupting the transmission of energy through any conductor when the current rises above a pre-determined amount.
2.1.29 Damp Situation — A situation in which moisture is either permanently present or intermittently present to such an extent as to be likely to impair the effectiveness of an installation conforming to the requirements for ordinary situations.
2.1.30 Dead — A portion of the circuit (normally expected to carry a voltage) at or near about earth potential or apparently disconnected from any live system.
2.1.31 Direct Earthing System — A system of earthing in which the parts of an installation are so earthed as specified but are not connected within the installation to the neutral conductor of the supply system or to earth through the trip coil of an earth leakage circuit-breaker.
2.1.32 Distance Area or Resistance Area (for Earth Electrode only) — The area of ground (around an earth electrode) within which a voltage gradient measurable with ordinary commercial instruments exists when the electrode is being tested.
2.1.33 Discrimination (Over-Current Discrimination) Co-ordination of the operating characteristics of two or more over-current protective devices such that, on the incidence of over-currents within stated limits, the device intended to operate within these limits does so, while the others do not.
NOTES
1 Protective devices should have discrimination so that only the affected part (minimum section) of the circuit is isolated, even though a number of protective devices may be in the path of the over current.
2 Distinction is made between series discrimination involving different over-current protective devices passing substancially the same over-current and network discrimination involving identical protective devices passing different proportions of the over-current.
2.1.34 Earth — The conductive mass of the earth, whose electric potential at any point is conventionally taken as zero.
2.1.35 Earth Continuity Conductor — The conductor, including any clamp, connecting to the earthing lead or to each other those parts of an installation which are required to be earthed. It may be in whole or in part the metal conduit or the metal sheath or armour of the cables, or the special continuity conductor of a cable or flexible cord incorporating such a conductor.
2.1.36 Earth Electrode — A conductor or group of conductors in intimate contact with and providing an electrical connection to earth.
2.1.37 Earth Fault — Accidental connections of a conductor to earth when the impedance is negligible, the connection is called a dead earth.
2.1.38 Earthing Lead — The final conductor by which the connection to the earth electrode is made.
2.1.39 Earth Leakage Circuit Breaker System — A system of earthing in which the parts of an installation, specified, to be earthed are so earthed through one or more earth leakage circuit-breakers or relays.
2.1.40 Enclosed Distribution Board — An enclosure containing bus bars with one or more control and protected devices for the purpose of protecting, controlling or connecting more than one outgoing circuits fed from one or more incoming circuits.
2.1.41 Exposed Metal — All metal parts of an installation which are easily accessible other than:
a) parts separated from live parts by double insulation;
b) metal name-plates, screw heads, covers, or plates, which are supported on or attached or connected to substantial non-conducting material only in such a manner that they do not become alive in the event of failure of insulation of live parts and whose means of fixing do not come in contact with any internal metal; and
c) parts which are separated from live parts by other metal parts which are themselves earthed or have double insulation.
2.1.42 Fire Survival Cable — A cable which continues in service after exposure to a temperature of 900°C for 20 min or 700°C for 90 min.
2.1.43 Fitting, Lighting — A device for supporting or containing a lamp or lamps (for example, fluorescent or incandescent) together with any holder, shade, or reflector, for example, a bracket, a pendant with ceiling rose, an electrolier, or a portable unit.
2.1.44 Flameproof Enclosure — An enclosure which will withstand without injury any explosion of inflammable gas that may occur within it under practical conditions of operation within the rating of the apparatus (and recognized overloads, if any, associated therewith) and will prevent the transmission of flame which may ignite any inflammable gas that may be present in the surrounding atmosphere.