2.2.1 Air Change per Hour — The amount of air leakage into or out of a building or room in terms of the number of building volume or room volume exchanged.
2.2.2 Axial Flow Fan — A fan having a casing in which the air enters and leaves the impeller in a direction substantially parallel to its axis.
2.2.3 Centrifugal Fan — A fan in which the air leaves the impeller in a direction substantially at right angles to its axis.
2.2.4 Contaminants — Dusts, fumes, gases, mists, vapours and such other substances present in air as are likely to be injurious or offensive to the occupants.
2.2.5 Dilution Ventilation — Supply of outside air to reduce the air-borne concentration of contaminants in the building.
2.2.6 Dry Bulb Temperature — The temperature of the air, read on a thermometer, taken in such a way as to avoid errors due to radiation.
2.2.7 Effective Temperature (ET) — An arbitrary index which combines into a single value the effect of temperature, humidity and air movement on the sensation of warmth or cold felt by the human body and its numerical value is that of the temperature of still saturated air which would induce an identical sensation.
2.2.8 Exhaust of Air — Removal of air from a building or a room and its disposal outside by means of a mechanical device, such as a fan.
2.2.9 Fresh Air or Outside Air — Air of that quality, which meets the criteria of Table 1 and in addition shall be such that the concentration of any contaminant in the air is limited to within one-tenth the threshold limit value (TLV) of that contaminant.
Notes
1 Where it is reasonably believed that the air of quality is unexpectable as indicated above, sampling and analysis shall
be carried out by a competent authority having jurisdiction and if the outside air of the quality specified is not available, filtration and other treatment devices shall be used to bring its quality to or above the levels mentioned in Table 1.
2 The list of contaminants given in Table 1 is not exhaustive and available special literature may be referred for data on other contaminants.
Table 1 Maximum Allowable Contaminant Concentrations for Ventilation Air Contaminants Annual Average (Arithmetic Mean)
(Clause 2.2.9)
| Contaminants | Annual Average (Arithmetic Mean)g/m<sup>3</sup> | Short-Term Level (Not to exceed More than Once a Year)g/m<sup>3</sup> | Averaging Period h |
|---|---|---|---|
| (1) | (2) | (3) | (4) |
| Suspended particulates | 60 | 150 | 24 |
| Sulphur oxides | 80 | 400 | 24 |
| Carbon monoxide | 20 000 | 30 000 | 8 |
| Photochemical oxidant | 100 | 500 | 1 |
| Hydrocarbons (not | 1 800 | 4 000 | 3 |
| including methanes) | |||
| Nitrogen oxide | 200 | 500 | 24 |
| Odour: Essentially | |||
| unobjectionable |
2.2.10 General Ventilation — Ventilation, either natural or mechanical or both, so as to improve the general environment of the building, as opposed to local exhaust ventilation for contamination control.
2.2.11 Globe Temperature — The temperature measured by a thermometer whose bulb is enclosed in a matt black painted thin copper globe of 150 mm diameter. It combines the influence of air temperature and thermal radiations received or emitted by the bounding surfaces.
2.2.12 Humidification — The process whereby the absolute humidity of the air in a building is maintained at a higher level than that of outside air or at a level higher than that which would prevail naturally.
2.2.13 Humidity, Absolute — The mass of water vapour per unit volume.
2.2.14 Humidity, Relative — The ratio of the partial pressure or density of the water vapour in the air to the saturated pressure or density respectively of water vapour at the same temperature.
2.2.15 Local Exhaust Ventilation — Ventilation effected by exhaust of air through an exhaust appliance, such as a hood with or without fan located as closely as possible to the point at which contaminants are
released, so as to capture effectively the contaminants and convey them through ducts to a safe point of discharge.
2.2.16 Make-up Air — Outside air supplied into a building to replace the indoor air.
2.2.17 Mechanical Ventilation — Supply of outside air either by positive ventilation or by infiltration by reduction of pressure inside due to exhaust of air, or by a combination of positive ventilation and exhaust of air.
2.2.18 Natural Ventilation — Supply of outside air into a building through window or other openings due to wind outside and convection effects arising from temperature or vapour pressure differences (or both) between inside and outside of the building.
2.2.19 Positive Ventilation — The supply of outside air by means of a mechanical device, such as a fan.
2.2.20 Propeller Fan — A fan in which the air leaves the impeller in a direction substantially parallel to its axis designed to operate normally under free inlet and outlet conditions.
2.2.21 Spray-Head System — A system of atomizing water so as to introduce free moisture directly into a building.
2.2.22 Stack Effect — Convection effect arising from temperature or vapour pressure difference (or both) between outside and inside of the room and the difference of height between the outlet and inlet openings.
2.2.23 Tropical Summer Index (TSI) — The temperature of calm air at 50 percent relative humidity which imparts the same thermal sensation as the given environment. TSI (in °C) is express as
- 7 4 5 t g + 0. 3 0 8 t w - 2. 0 6 √(v) + 0. 8 4 1
where
t g = Globe temperature, ° C;
i w = Wet bulb temperature, ° C; and
v = Wind speed, m / s.
2.2.24 Threshold Limit Value (TLV) — Refers to airborne concentration of contaminants currently accepted by the American Conference of Governmental Industrial Hygienists and represents conditions under which it is believed that nearly all occupants may be repeatedly exposed, day after day, without adverse effect.
2.2.25 Velocity, Capture — Air velocity at any point in front of the exhaust hood necessary to overcome opposing air currents and to capture the contaminants
in air at that point by causing the air to flow into the exhaust hood.
2.2.26 Ventilation — Supply of outside air into, or the removal of inside air from an enclosed space.
2.2.27 Wet Bulb Temperature — The steady temperature finally given by a thermometer having its bulb covered with gauze or muslin moistened with distilled water and placed in an air stream of not less than 4.5 m/s.