61. Public Sanitary Convenience (PSC) Blocks/Toilets
With the approval of the Commissioner, PSC block may be constructed, maintained and made available for general public use on Municipal/Govt. plots, which are reserved/ existing amenity for public purpose in the following manner:
i) The location of PSC blocks shall be such that the same are accessible for general public use.
ii)The toilets shall be maintained by the user of the plot or as decided by the Commissioner.
iii)On plots having non-buildable/POS reservation/existing amenity and having area more than 4,000 sq. m, 2 toilets and 2 urinals each for ladies and gents may be constructed and preferably one toilet for differently abled persons and one urinal for children shall be constructed.
iv)On plots having non-buildable/POS reservation/existing amenity and having area less than 4,000 sq. m, 1 toilet and 2 urinals each for ladies and gents maybe constructed.
v) On plots having buildable reservation/ amenity and having area more than 2000 sq. m, 1 toilet and 2 urinals each for ladies and gents and preferably one toilet for differently abled persons and one urinal for children shall be constructed while developing the plot. On plots having buildable existing amenity and having area more than 2000 sq. m, 1 toilet and 2 urinals each for ladies and gents and preferably one toilet for differently abled persons and one urinal for children may be constructed. The PSC so proposed preferably shall have access directly from the public street and shall be located in such a way that, it shall not cause nuisance to the occupants of the plot and same shall have to be maintained as decided by the Commissioner in hygienic condition. Efforts shall be made to construct PSC blocks at a distance of every 3 km. especially near the bus stop along highway/major roads taking in to consideration other requirements for provision of PSC block.
vi)Construction of such PSC may be allowed touching the plot boundary and accessible from Public Street. The joint open space between the structure of primary user and the structure for PSC shall not be less than required front open space for structure of primary user or 3 m whichever is higher.
vii) The PSC to the extent specified shall be permissible free of FSI.
viii) Availability of PSC shall be displayed in such a way that it is clearly seen from Public Street.
ix) Substation can be provided above PSC as per the requirement of Electric Supply Company subject to NOC from CFO.
62. Rain Water Harvesting (RWH)
General: The Rain Water Harvesting (RWH) arrangement shall be provided in case of Development/Redevelopment of plots having area of 500sq. m and more. It shall have one or more RWH structures having a minimum total capacity as detailed in schedule below;
Provided that the professional on record shall certify that the RWH System /Structures have been constructed as per the specification or of specifications different from those in Schedule, subject to the minimum capacity of RWH System being ensured in each case.
The owner/society of every building shall ensure that the RWH structure/system is maintained in good condition for storage of water for non-potable purposes or recharge of ground water at all times.
The Authority may impose a levy of not exceeding Rs.1000/- per annum for every 100 Sq.Mt. of builtup area for the failure of the owner of any building mentioned above to provide or to maintain Rain Water Harvesting structures as required under these byelaws.
PART – XII ENVIRONMENTAL SUSTAINABILITY