(i) The Maharashtra Regional and Town Planning Act, 1966 (Mah. Act No. XXXVII of 1966); or
(ii) The Mumbai Municipal Corporation Act, 1888 (Mumbai Act No. III of 1888)
PART-I ADMINISTRATION
(6) "Addition and/or alteration" means change from one occupancy to another, or a structural change, such as addition to the area or height, or the removal of part of a building, or a change to the structure, such as the construction or cutting into or removal of any wall or part of a wall, partition, column, beam, joist, floor including a mezzanine floor or other support, or a change to or closing of any required means of ingress or egress, or change to fixtures or equipment, as provided in these Regulations.
(7) "Advertising sign" means any surface or structure with characters, letter or illustrations applied thereto and displayed in any manner whatsoever out of doors for the purpose of advertising or giving information regarding or to attract the public to any place, person, public performance, article or merchandise, and which surface or structure is attached to, forms part of, or is connected with any building, or is fixed to a tree, or to the ground or to any pole, screen, fence or hoarding or displayed in space or in or over any water body included in the limits of Greater Mumbai i.e. Island City, Suburbs or extended Suburbs as defined in section 3 of the Mumbai Municipal Corporation Act, 1888, and area specified in Part II to IV of Schedule `A` to the Greater Mumbai Laws and Mumbai High Court (Declaration of Limits) Act,1945.
However, advertising sign shall not include hoarding displaying details of the project as per IOD/IOA condition, at the site of the project.
(8) "Air-conditioning" means the process of treating air to control simultaneously its temperature, humidity, cleanliness and distribution to meet the requirement of an enclosed space.
(9) “Alcove” means a cooking place with direct access from the main room without a communicating door.
(10) “Amenity Space” means a statutory space provided in any layout/plot to be used for any of the amenities/utilities specified in these regulations
(10A) “Affordable Housing” means social housing in the nature of housing meant for economically weaker section, lower income group having carpet area of 27.88 sq. mt. (300 sq. ft) or of such area as may be decided by Govt. from time to time.
(11) "Architect" means a person registered as an architect under the provisions of the Architects Act, 1972.
(12) “Atrium” means the area comprised of entrance lobby or common entrance hall of the building or common area at any single floor level which serves as a Common Open Spaces for more than one floor.
(13) "Automatic sprinkler system" means an arrangement of pumps, pipes and sprinklers, set to activate automatically on detection of fire inside the building and spray water under force to douse fire, simultaneously setting an audible alarm.
(14) "Balcony" means a horizontal projection, including a parapet, hand-rail balustrade, to serve as a passage or sitting out place.
(15) "Basement or cellar" means the lower storey of a building below, or partly below the ground level.
(16) “Biotechnology Unit” means and includes Biotechnology units which are certified by the Development Commissioner (Industries) or any other officer authorized by him on his behalf.
(17) "Building” means a structure, constructed with any materials whatsoever for any purpose, whether used for human habitation or not, and includes-
PART-I ADMINISTRATION
(i) Foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms;
(ii) Verandahs, balconies, cornices, projections;
(iii) part of a building or anything affixed thereto;
(iv) any wall enclosing or intended to enclose any land or space, signs and outdoor display structures;
(v) tanks constructed for storage of chemicals or chemicals in liquid form;
(vi) all types of buildings defined in (a) to (r) below; but tents, shamianas and tarpaulin shelters erected for temporary purposes for ceremonial occasions, with the permission of the Commissioner, shall not be considered to be "buildings".
(a) "Assembly building" means a public building or part thereof where groups of people congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes. "Assembly buildings" include buildings of drama and cinema theatres, drive-in-theatres, assembly halls, city halls, town halls, auditoria, exhibition halls, museums, mangal karyalayas, skating rinks, gymnasia, stadia, restaurants, eating or boarding houses, places of worship, dance halls, multipurpose hall, clubs, gymkhanas, malls, road, air, sea or other public transportation stations, and recreation piers. Public for this purpose shall mean use open for public at large.
(b) "Business building" means any building or part thereof used for transaction of business and/or keeping of accounts and record there for; offices, banks, professional establishments, IT establishments, call centers, offices for private entrepreneur, provided their principal function is transaction of business and/or keeping of books and records.
(c) "Detached building” means a building with walls and roofs independent of any other building and with open spaces on all sides.
(d) "Educational building" means a building exclusively used for a school or college, recognized by the appropriate Board or University, or any other competent authority involving assembly for instruction, education or recreation incidental to educational use, and including a building for such other uses incidental thereto such as a library, multipurpose hall, auditorium or a research institution. It shall also include quarters for essential staff required to reside in the premises, and a building used as a hostel captive to an educational institution whether situated in its campus or not, Hostel for girls student.
(e) "Hazardous building" means a building or part thereof used for-
(i) storage, handling, manufacture or processing of radioactive substances or of highly combustible or explosive materials or products which are liable to burn with extreme rapidity and/or producing poisonous fumes or explosive emanations;
(ii) storage, handling, manufacture or processing which involves highly corrosive, toxic or noxious alkalis, acids, or other liquids, gases or chemicals producing flame, fumes and explosive mixtures or which result in division of matter into fine particles capable of spontaneous ignition.
PART-I ADMINISTRATION
(f) "Industrial building" means a building or part thereof wherein products or material are fabricated, assembled or processed, such as assembly plants, laboratories, power plants, refineries, gas plants, mills, dairies and factories
(g) "Institutional building" means a building constructed or used for education, health, research and such other activities, hostel for working women/persons/students, but not for lodging or for an auditorium or complex for cultural and allied activities or for an hospice, care of persons suffering from physical or mental illness, handicap, disease or infirmity care of orphans, abandoned women, children and infants, convalescents, destitute or aged persons and for penal or correctional detention with restricted liberty of the inmates ordinarily providing sleeping accommodation, and includes dharamshalas, hospitals, sanatoria, custodial and penal institutions such as jails, prisons, mental hospitals, houses of correction, detention and reformatories.
(h) “Information Technology Building” means a building used for the purpose of business of developing either software or hardware or providing IT enabled services as defined in IT policy amended from time to time.
(i) "Mercantile building" means a building or part thereof used as shops, stores or markets for display and sale of wholesale or retail goods or merchandise, including office, storage and service facilities incidental thereto located in the same building.
(j) "Office building" (Premises), means a building or premises or part thereof whose sole or principal use is for an office or for office purposes. "Office purposes" includes the purpose of administration, handling money, telephone, telegraph and computer operation and such other activities; and including writing, book-keeping, sorting papers, typing, filing, duplicating, data processing, drawing of matter for publication and editorial preparation of matter for publication and such other activities.
(k) “Public Building” means a building used or intended to be used either ordinarily or occasionally by the public such as;
(a) offices of Central or State Government or any Public-Sector Undertaking or Statutory Authority or Local Authorities
or (b) buildings such as;
i. temple, mosque, church, chapel, or any place of public worship.
ii. public or private college, school, library, or places of educational facilities.
iii. cinema, public concert hall, drama theatre, auditorium, sports complex, sports facility, theatre for cultural activities.
iv. public hall, welfare centre, exhibition hall, Museum or any other place of assembly.
v. hospital, maternity home etc. or any other place of medical facility.
vi. market, shopping centre, departmental store or mall with or without multiplex or any other place of retail and wholesale merchandise.
vii. railway station, metro/mono rail station, bus station, airport or any other public transport terminal.
viii. public or private hospital
PART-I ADMINISTRATION
(l) "Residential building" means a building in which sleeping accommodation is provided for normal residential purposes, with or without cooking or dining facilities, and includes one or more family dwellings, lodging or rooming houses, hostels, dormitories, apartment houses, flats, and private garages of such buildings.
(m) “Semi-detached building" means a building detached on three sides.
(n) “Special building" means-
(i) a building solely used for the purpose of a drama or cinema theatre, a drive-in-theatre, an assembly hall or auditorium, an exhibition hall, theatre museum, a stadium, a "Mangal Karyalaya", exceeding built-up area of1000 sq. m or where the built-up area of such a user exceeds 1000 sq. m in the case of mixed occupancies;
(ii) an industrial building;
(iii) a hazardous building;
(iv) a building of wholesale establishment;
(v) Educational, Institutional and residential hotel building or centrally air-conditioned building which exceeds
(a) 15m in height, or
(b) a total built-up area of1000 sq. m.
(o) "Storage building" means a building or part thereof used primarily for storage or shelter of goods, wares or merchandise, warehouse, cold storage, freight depot, transit shed, store house, public garage hangar, truck terminal, grain elevator and barn.
(p) “Temporary Building/structure” means any building/structure of whatever size and of whatever material which the Commissioner has allowed to be built as a temporary measure in accordance with Regulation No 57.
(q) "Unsafe building" means a building which-
(i) is structurally unsafe,
(ii) is insanitary,
(iii) is not provided with adequate means of egress,
(iv) constitutes a fire hazard,
(v) is dangerous to human life,
(vi) in relation to its existing use, constitutes a hazard to safety or health or public welfare by reasons of inadequate maintenance, dilapidation or abandonment.
(r) "Wholesale establishment" means an establishment wholly or partly engaged in wholesale trade and manufacturers wholesale outlets, including related storage facilities, warehouses and establishments engaged in truck transport, including truck transport booking agencies.
(18)"Building line" means the line up to which the plinth of a building extends in any development.
(19)"Built-up area" means the area covered by a building on all floors including cantilevered portion, if any, but excluding cladding and areas specifically exempted under these Regulations for the purpose of computation of FSI.
PART-I ADMINISTRATION
(20) "Cabin" means a non-residential enclosure constructed of non-load bearing partitions.
(21) “Canopy” means a cantilevered projection over any building entrance.
(22) "Carpet area" would have the same meaning as defined in Real Estate (Regulation and Development) Act, 2016.
(23) "Chimney" means a construction by means of which a flue is formed for the purpose of carrying products of combustion to the open air and includes a chimney stack and the flue pipe.
(24) "Chajja" means a structural overhang provided over openings on external walls for protection from the weather.
(25) "Chowk" means a fully or partially enclosed space permanently open to the sky within a building at any level; inner chowk being enclosed on all sides and an outer chowk having one unenclosed side.
(26) "Chute" means a vertical system passing from floor to floor provided with ventilation and inlet openings for receiving refuse from successive floors with or without sprinklers for cleaning and ending at the ground floor on the top of the collecting chambers.
(27) “Cluster” means any defined area with proper access comprising dwelling units, buildings, chawls, etc.
(28) "Combustible material" means that material which when burnt adds heat to a fire when tested for combustibility in accordance with the IS: 3808-1966 Method of Test for combustibility of Building Materials, National Building Code.
(29) “Commissioner” means Municipal Commissioner of Greater Mumbai or any other officer designated by him.
(30) "Contiguous holding" means contiguous piece of land under one ownership irrespective of separate property register cards.
(31) “Conversion” means the change of occupancy or premises to any occupancy or use requiring development permission.
(32) "Convenience shopping,” means shops, each with a carpet area not exceeding 30 sq. m except where otherwise indicated and comprising those dealing with day to day requirements, as distinguished from wholesale trade or shopping, provided on the ground and/or first floor of building with internal means of access. It includes-
(i) Food grain or ration shops,
(ii) Pan shops.
(iii) Shops for collecting and distribution of clothes and other materials for cleaning and dyeing establishments.
(iv) Tailor or darner shops.
(v) Groceries, confectioneries, wine and general provision shops
(vi) Hair dressing saloons and beauty parlours.
(vii) Bicycles hire and repair shops.
(viii) Vegetable and fruits shops.
(ix) Milk and milk products shops.
PART-I ADMINISTRATION
(x) Medical and dental practitioners’ dispensaries or clinics, pathological or diagnostic clinics and pharmacies, each with a carpet area not exceeding 100sq. m.
(xi) Florists.
(xii) Shops dealing in ladies’ ornaments such as bangles, etc.
(xiii) Shops selling bakery products.
(xiv) Newspaper magazines stalls and circulating libraries.
(xv) Books and stationery shops or stores.
(xvi) Cloth and garment shops.
(xvii) Plumbers', electricians, radio, television and video equipment repair shops and video libraries.
(xviii) Restaurants and eating houses of area not exceeding 150 sq. m
(xix) Shoes and sports shops each with a carpet area not exceeding 100 sq. m.
(xx) Coaching Classes with a carpet area not exceeding 100 sq. m.
(xxi) Gymnasium not exceeding 150 sq. m.
(xxii) Any other shop covered under the definition of convenience shopping, to whom license under the shops and establishment has been issued under the MMC Act.
With the special permission, the Commissioner may from time to time add to, alter or amend the above list.
(33) "Corridor” means a common passage or circulation space including a common entrance hall.
(34) "Courtyard" means a space permanently open to the sky within the site around a structure or surrounded by structure and may be paved/concreted.
(35) “Curb Cut” means a small solid (usually concrete) ramp that slopes down from the top surface of a side walk or footpath to the surface of an adjoining street. It is designed for ease of access for pedestrians, bicyclists and differently abled people.
(36) “Demonstrable Hardship” Demonstrable hardship means plot under development/ redevelopment affected due to Nalla, Nallah/river buffer, road widening, height restriction due to statutory restriction as per these Regulations such as railway buffer, height restrictions in the vicinity of Airport, height restriction in the vicinity of defence establishments, and/or any other restrictions as per the provisions of these Regulations affecting the project, odd shape plot, rehabilitation of existing tenants/occupants on small size plot/s etc.
(37) “Developer/Builder/Project Proponent” means the person who is legally empowered to carry out the development.
(38) "Dharmashala" means a building used as a place of religious assembly, a rest house, a place in which charity is exercised with religious or social motives, or a place where in a certain section of people have a right of, or are granted, residence without payment or on nominal payment.
(39) "Drain" means a system or a line of pipes, with their fittings and accessories such as manholes, inspection chambers, traps, and gullies, floor traps used for drainage of buildings or yards appurtenant to the buildings within the same curtilage. A drain includes an open channel for conveying surface water or a system for the removal of any liquid.
PART-I ADMINISTRATION
(40) “Dwelling Unit/Tenement” means an independent housing unit with separate facilities for living, cooking and sanitation.
(41) “Eating House” means any premises where any kind of food is prepared or supplied for consumption of public.
(42) "Enclosed staircase" means a staircase separated by fire resistant walls and door from the rest of the building.
(43) “Energy Efficient Building” means the building (having connected load 100 KW or greater and having conditioned area of 1000 sq. m or more) compliant with the provisions of ECBC code.
(44) “Escalator” means a power driven, inclined, continuous stairway used for ascending or descending between floors or bridge over the road/railway line.
(45) "Escape route" means any well ventilated corridor, staircase or other circulation space, or any combination of the same, by means of which a safe place in the open air at ground level can be reached.
(46) "Existing building" means a building or structure existing authorisedly before the commencement of these Regulations.
(47) "Existing use” means use of a building or a structure existing authorisedly before the commencement of these Regulations.
(48) "Exit" means a passage channel or means of egress from any building, storey or floor area to a street or other open space of safety; horizontal, outside and vertical exits having meanings at (i), (ii) and (iii) respectively as under:
(i) "Horizontal exit" means an exit which is a protected opening through or around a fire wall or a bridge connecting two or more buildings.
(ii) "Outside exit" means an exit from a building to a public way, to an open area leading to a public way or an enclosed fire resistant passage leading to a public way.
(iii) "Vertical exit" means an exit used for ascending or descending between two or more levels, including stairways, smoke-proof towers, ramps, escalators and fire escapes.
(49) "External wall" means an outer wall of a building not being a partition wall even though adjoining a wall of another building and also means a wall abutting on an interior open space of any building.
(50) "Fire and/or emergency alarm system" means an arrangement of call points or detectors, sounders and other equipment for the transmission and indication of alarm signals, activated automatically or manually in the case of fire or other emergency.
(51) "Fire Booster pump" means a mechanical/electrical device installed at intermittent level to boost up the water pressure so as to achieve the required pressure of 3.2 kg/cm2 at the top level of high rise building or at the nearest point.
(52) "Fire lift" means a special lift designed for the use of fire service personnel in the event of fire or other emergency.
(53) "Fire proof door" means a door or shutter fitted to a wall opening, made of fire resistant material to prevent the transmission and spread of heat and fire for a specified period.
(54) "Fire Pump" means a machine, driven by external power for transmitting energy to fluids by coupling the pump to a suitable engine or motor, which may have varying outputs/capacity but shall be capable of having pressure of 3.2 kg/cm2 at the topmost level of a high rise building.
PART-I ADMINISTRATION
(55) "Fire resistance" means the duration of time which a fire resistant material i.e. material having a certain degree of fire resistance, fulfills its function of contributing to the fire safety of a building when subjected to prescribed conditions of heat and load or restraint. The fire resistance test of structures shall be done in accordance with IS: 3809-1966 Fire Resistance Test of Structure.
(56) "Fire separation" means the distance in meters measured from any other building on the site or from another site, or from the opposite side of a street or other public space to the building.
(57) "Fire service inlet" means a connection provided at the base of a building for pumping up water through in-built fire-fighting arrangements by fire service pumps in accordance with the recommendations of the Chief Fire Officer.
(58) "Fire tower" means an enclosed staircase which can only be approached from the various floors through landings or lobbies separated from both the floor area and the staircase by fire-resisting doors and open to the outer air.
(59) “Fitness centre/Yogalaya in a building” means and includes the built-up premises including toilet facilities provided in the building including gymnasium for the benefit of its inmates and for the purpose of fitness, physical exercises, yoga, reading and such other activities as may be permitted by the commissioner from time to time
(60) "Floor" means the lower surface in a storey on which one normally walks in a building, and does not include a mezzanine floor. The floor at ground level with a direct access to a street or open space shall be called the ground floor; the floor above it shall be termed as floor 1, with the next higher floor being termed as floor 2, and so on upwards.
(61) "Floor space index (FSI)" means the quotient of the ratio of the combined gross floor area of all floors, excepting areas specifically exempted under these Regulations, to the area of the plot, viz.:
Total covered area on all floors
Floor Space Index (FSI) =