(a) May be constructed with the locational approval from the Hydraulic Engineering Department of MCGM.
(b) The construction shall be as per the provision of State Ground Water Survey Department.
(26) Overhead Tanks: Every overhead water storage tank shall be maintained in proper hygienic condition. The distance between terrace & soffit of the overhead water tank shall not exceed 1.5 m. The construction of the water storage tanks shall be as per the guidelines issued by Hydraulic Engineering Department of MCGM.
(27) Septic Tanks-Location and sub-soil dispersion: A sub-soil dispersion system shall not be closer than 12m to any source of drinking water such as a well, to mitigate the possibility of bacterial pollution of water supply. It shall not be closer than 3 m from Tube well/Bore well. It shall also be as far removed from the nearest habitable building as economically feasible but not closer than 2 m to avoid damage to the structure.
The construction of septic tank shall be carried out as per the relevant provisions of IS Code 2470-1985 Part I & II.
(28) Yogalaya or Fitness Centre: In every residential building, either existing or constructed or proposed to be constructed for the use of existing or proposed Co-Operative Housing Society or an Apartment Owners Association, a Yogalaya or Fitness Centre including toilet facilities will be permitted subject to following conditions:
i. The application for the proposed Yogalaya or Fitness Centre shall be made by the Registered Co-Operative Housing Society/Apartment Owners Association of the buildings that has been issued the occupation certificate/BCC. The owner/developer may make an application for proposed Yogalaya or Fitness Centre with registered undertaking stating that constructed Yogalaya or Fitness Centre shall be handed over to proposed Co-Operative Housing Society/Apartment Owners Association; and in turn shall ensure the handing over on completion.
ii. The area of such center shall be allowed free of FSI equivalent to 2(two) percent of the total BUA for every building distributed as desired.
Any additional BUA, in excess of this limit would be counted towards FSI.
iii. The center shall not be used for any purpose other than for fitness centre activities and Reading Room.
iv. The Yogalaya or Fitness Centre activities shall be exclusively confined for to the members of the concerned housing society or an Apartment Owners Association.
v. The ownership of the premises of the Yogalaya or Fitness Centre shall vest only with the concerned society or the apartment owner’s association as the case may be.
vi. In case of larger layout where there is existing/proposed Club House in layout RG under Regulation 27 of these regulations, then the Yogalaya or Fitness Centre in the individual building shall not be permissible free of FSI.
(29) Special Provisions for Institutional, Assembly, Business or Mercantile and Industrial Buildings: A Crèche of minimum 40 sq. m BUA shall be provided for Institutional, Assembly, Business or Mercantile Building where total number of employees is 1000or more.
(30) Parking floor: The parking floors above ground/stilt floor within building line, for the provision of parking, accessible either by ramp or by minimum two car lifts up to 200 parking and one additional car lift for every 100 parking beyond 200 parking or part thereof. The height of the parking floor shall not be more than 2.4m below soffit of the beam& maximum height of the floor permitted in this regulation below soffit of slab. In case of mechanical parking more height as per the requirement may be allowed.
(31) Podium: A podium may be permitted in plot admeasuring 1000 sq. m or more.
The podium provided with ramp may be permitted in one or more level, total height not exceeding 32 m above ground level.
Podium not provided with ramp but provided with car lifts may be allowed subject to minimum two numbers, for vehicles up to 200 parking and one additional car lift for every 100 parking beyond 200 parking or part thereof.
The podium shall be used for the parking of vehicles, provision of DG set, and substation as per requirement of electric supply company. Further, drivers’ room, toilet block, society office, Air Handling Unit (AHU) and Yogalaya or Fitness Centre, swimming pool on top most podium open to sky may also be permitted without affecting recreational area if provided and if other requirements of these Regulations are fulfilled.
The LOS as laid down under Regulation No 27, may be provided as per note therein. The additional LOS, if any, may be provided on the podium.
Podium may be allowed to be constructed beyond building line in the required front open space under the provisions of these Regulations provided clear distance of 3.0 m between plot boundary/edge of road and podium line is maintained.
Such podium may be extended beyond the building line in consonance with provisions of DC Regulation 47(1)
Ramps may be provided in accordance with DC Regulation 37(16).
(32) Service Floor: A service floor of height not exceeding 1.8 m may be provided in a building exclusively for provision/diversion of services. Provided further that a service floor with height exceeding 1.8 m may be allowed in a building of medical use or in building having height more than 70 m with the special permission of Commissioner with reasons recorded in writing.
(33) Helipad: A helipad may be allowed on the rooftop of the building subject to
(i) structural stability certificate from the registered Structural Engineer,
(ii) All other statutory permissions.
(iii) unrestricted access as required by MCGM/any Government agencies in case of emergency and submission of registered undertaking to that effect.