The following shall not be counted in FSI
(i) Areas of structures permitted in LOS under clause (g)of sub-Regulation (1) of Regulation No 27.
(ii) Areas covered by features permitted in open spaces as listed in Regulation No.42 except for Regulation 42(i) (b), 42(ii)(d),42(ii) (e) (ii) , 42(ii) (f) (ii)
(iii) Areas covered by staircase rooms, lift machine rooms above topmost storey, staircase/lift wells and passages in stilt, basement and floors exclusively used for parking and other ancillary uses as permitted in this Regulation No.31(1)
(iv) Areas covered by staircases/lift wells including lobbies as specified, excluding those covered under DC Regulation No.31 (1) (iii) with special written permission of the Commissioner subject to payment of premium.
Such exclusion from FSI computation shall not be applicable in case of existing buildings.
Provided further that where the permissible FSI has not been exhausted in the case of existing buildings and cases decided by the Corporation prior to coming into force of these Regulations, the exclusion from FSI computation as in these Regulations will be available for construction of balance potential,
Provided further that for the reconstruction scheme under Regulation No. 33(6), 33(7)A, 33(7)B such exclusion will be permissible as hereunder: -
If staircase, lift & lift lobby areas are claimed free of FSI by charging premium as per then prevailing Regulation, then such areas to that extent only will be granted free of FSI without charging premium. If staircase, lift & lift lobby areas are counted in FSI in earlier development, such areas may be availed free of FSI by charging premium as per these Regulations.
i. While working out total existing BUA, the BUA of existing staircase will not be taken into account.
ii. Premium for the area of the staircase and lift-well will be recovered after working out the area of the staircase and lift-well in the proposed building minus area of the existing staircase, lift-well etc., if any
(v) Area of the basement used exclusively for parking and other ancillary uses as permitted in Regulation No. 37(7) (iv) (b, c, d, e & j).
(vi) Area of covered parking spaces as provided in sub-Regulation (6) (a)of Regulation No.44 Provided, however, that additional parking to the extent of 50%of the required parking may be permitted without payment of premium.
Provided further that in non-residential building, where entire parking is proposed by mechanical/ automatic means, additional parking to the extent of 20% of the required parking shall be permitted free of FSI as vehicle holding area.
PART - V FLOOR SPACE INDEX
(vii) Area of one office room as provided in sub-Regulation (9) of Regulation 37
(viii) Lofts [vide sub-Regulation 4 of Regulation 37]
(ix) Porches [vide sub-Regulation (18) of Regulation 37].
(x) Canopy [vide sub-Regulation (19) of Regulation 37].
(xi) Area of structures for an effluent treatment plant, Water Treatment Plant, Sewerage Treatment Plant as required to be provided, as per the requirements of the MPCB or other relevant authorities: Provided, however, in the case of an existing industry, if no vacant land is available the Commissioner may permit structures with dimensions to be approved by him for such effluent treatment plant on 15 per cent layout open space.
(xii) A chajja, cornice, weather shade, sun-breaker, at lintel level, only & vertical fins (excluding column); projecting not more than 1.2 m. from the face of the building as provided in sub regulation no. 42 (ii) (e)(i).
(xiii) A chajja, cornice, weather shade, sun-breaker over a balcony or gallery, as provided in sub regulation no. 42(ii)(f)(i)
(xiv) Area covered by elevated/underground water reservoirs/tanks, electric sub-stations, Distribution Sub Station, pump houses, facility for treatment of wet waste in situ.
(xv) Area covered by new lift and passage thereto in an existing building with a height up to 16m. in the Island City [vide clause (ii) (f) of sub-Regulation (17) of Regulations 37]
(xvi) Area of a covered passage of clear width not more than 1.52m (5ft.) leading from a lift exit at terrace level to the existing staircase so as to enable descent to lower floor in a building to reach tenements not having direct access to a new lift in a building without an existing lift.
(xvii) Area of one fitness centre /Yogalaya for a Co-Op. Housing Society or Apartment Owners Association as provided in sub-regulation 37(28).
(xviii) The fire chutes as provided under DC Regulation No. 48(9)
(xix) The refuge areas subject to DC Regulation No. 48(8)
(xx) Service Floor of height not exceeding 1.8 m or as stated in Regulation No.37(32).
(xxi) Entrance lobbies in stilted portion, height not exceeding 7.2 m. or height equivalent to two floor or height of stilt whichever is more.
(xxii) Open to sky swimming pool at the terrace above the top most storey or on the top most podium only.
(xxiii) Area of the service ducts abutting Sanitary Block, kitchen not exceeding 1.2 m. in depth. In case of high rise buildings higher width/size as per requirement and design approved by Commissioner but not exceeding 2.0 m.
(xxiv) Ornamental projection of cladding/glass façade/glazing not exceeding 0.30 m from building line for residential/non-residential building.
(xxv) Area covered by chimney, elevated tanks (provided its height below the tank from the floor does not exceed 1.5 m)
PART - V FLOOR SPACE INDEX
(xxvi) Area of sanitary block for use of domestic servants engaged in the premises, not exceeding 2.2 sq. m at staircase mid-landing level and/or at stilt level, area of sanitary block for use of drivers engaged by the car owners not exceeding 2.2 sq. m at each of the parking floor level /podium. In case number of car parks exceeds 200 per parking floor level /podium, additional sanitary block for every 200 cars or part there of shall be allowed.
(xxvii) Letter boxes as specified in Regulation No 37(10) (b)
(xxviii) Parking floors as specified in Regulation No37(30)
(xxix) Area of DG set at stilt and podium level as specified in Regulation No 37(31)
(xxx) Area of DG set, electric sub-station with protective walls having voids/perforated walls above 1 m height, at stilt and podium level or in side and rear marginal open space, or in a separate independent structure specified in Regulation No 37(31)
(xxxi) Electrical Duct/ fire duct of clear depth not more than 0.45 m and not abutting to any habitable room.
(xxxii) Area of electric meter/service utility room/rooms having area of 10 sq. m per 50 tenements at Basement /Ground/Stilt/Podium. In case of High Rise building the meter room may be allowed as per the specific requirements of Electric Supply Company.
(xxxiii) Refuse Chute/Garbage Shaft as specified in Regulation No.37(12)
(xxxiv) Elevation feature or dome like structure above water tank/lift machine room/staircase room up to 2 m for building with height beyond 32 m & up to 70 m, 6 m for the building height beyond 70 m and up to 120 m and up to 9 m for building with height beyond 120 m with 60% voids in surface area/profile may be allowed.
(xxxv) Area required for Rain Water Harvesting Arrangement, Non-conventional Energy System as per these Regulations.
(xxxvi) Advertisements and sky signs, covered areas required on topmost terrace for antenna/dish antenna/communication tower used for Telecom not exceeding 20 sq. m.
(xxxvii) Area required for Cooling Towers/Chilling Plants (open to sky) only beyond the required marginal open spaces or on terrace floor.
(xxxviii) Area for Laundry, Boiler Room for Hotels, Hospitals & Hostels as specified in Regulation No.37(7).
(xxxix) Room with maximum size 5 sq. m, for Battery back-up for solar water heater and/or for common lighting in basement or on terrace.
(xxxx) Entry gate over Arch.
i. Areas covered by the projections exceeding those specified in clauses xii, xiii, xxiii, xxiv and xxxiii above shall be counted in FSI.
ii. Open to sky swimming pool at any level other than (xxii) above and excluding at ground level as provided in Regulation No 42 (ii)(a), shall be counted in FSI.
iii. Any passage by whatever name not covered under DCR 31(1) shall be counted in FSI.
PART - V FLOOR SPACE INDEX
(2) The following shall be counted in FSI.
(i) Covered parking spaces/Garage as provided under Regulation No. 44 (6)(d)
(ii) Area of fire escape balcony as provided in Regulation No 48(6)
(iii) Area of Sanitary block for the use of domestic servants engaged in the premises, other than as provided as per Regulation No 31(1) ((XXVI)
(iv) Part/Pocket/Covered terraces, for whatever purpose, except open terrace above the top most storey and the part terrace at top most storey due to planning constraints but accessible from common staircase, terraces created due to restriction imposed by the Railway Authority and above shopping/Non-residential / Industrial area at one level only with a slope of 1:5, in case of residential / Non-residential/Industrial development on upper floors.
(v) Area below open to sky swimming pool, clearance exceeding 1.5 m. from floor level.
(vi) Air conditioning plant room/Air handling unit room, except provided in basement.
(vii) Service floor other than specified in Regulation No.37(32) and 31(1)(xx).
(viii) Area of balconies as provided in sub regulation 20 of Regulation No 37.
(ix) Niches below window sill.
(x) Area of one public telephone booth and one telephone exchange (PBX) room per building.
(xi) The ornamental projection, including the voids, flower beds, etc. projecting from the face of the building except at the terrace level other than allowed as per Regulation No 31(1) (ii).
(xii) Ornamental projection, flower bed etc. over a balcony or gallery other than allowed as per Regulation No 31(1) (ii).
(xiii) Area of one room for installation of telephone concentrators as per requirements of Mahanagar Telephone Nigam limited.
(xiv) Letter box room as specified in Regulation No 37(10) (a).
(xv) Covered areas required on top terrace for antenna/dish antenna/communication tower used for Telecom (basic cellular or satellite telephone) or ITE purposes, V-Sat, Routes, Transponders or similar IT related structure or equipment, in excess of 20.00 sq. m.
(xvi) The parking floor in excess of required parking under these regulation [31(1)(vi)]and for which the premium has been paid. Deck parking inclusive of car lifts and passages thereto on habitable floors.
(xvii)Driver’s room/sanitary block on podium and or parking floor other than mentioned in Regulation No.31(1)(xxvi).
(xviii) Covered swimming pool.
(xix) Area of DG set room at stilt and podium level other than mentioned in Regulation No 31(1)(xxx)