40. Lighting and Ventilation
(1) Adequacy and manner of provision- All parts of any habitable room shall be adequately lighted and ventilated. For this purpose, every room shall have -
(a) one or more apertures, excluding doors, with area not less than one-sixth of the floor area of the habitable room, with no part of any habitable room being more than7.50 m away from the source of light and ventilation. However, a staircase shall be deemed to be adequately lighted and ventilated, if it has one or more openings, their area taken together measuring not less than 1 sq. m per landing on the external wall;
(b) an opening with a minimum area of 1 sq. m in any habitable room including a kitchen, and 0.3 sq. m with one dimension of 0.3 m for any bathroom, water closet or store;
(c) all the walls, containing the openings for light and ventilation fully exposed to an exterior open space either directly or through a balcony not exceeding 2m. in width provided that a room meant for non-residential user shall be considered as adequately lighted and ventilated if its depth from the side abutting the required open space does not exceed 12 m and in case centrally air-conditioned building may be allowed to be exceeded up to 20 m.
(2) Artificial ventilation shaft- A bathroom, water closet, staircase or store/prayer room may abut on the ventilation shaft, the size of which shall not be less than the values given below:
| Height of buildings in metres.(m) | Cross-section of ventilation shaft in sq. m | Minimum dimension of one side of shaft in metres (m). |
|---|---|---|
| Upto 12 | 2.8 | 1.2 |
| Upto 18 | 4.0 | 1.5 |
| Upto 24 | 5.4 | 1.8 |
| Upto 30 | 8.0 | 2.4 |
| Above 30 | 9.0 | 3.0 |
Mechanical ventilation system shall invariably be installed in such ventilation shafts. Further, such ventilation shaft shall be adequately accessible for maintenance.
(3) Artificial Lighting & Mechanical Ventilation- Where lighting and ventilation requirements are not met through day-lighting and natural ventilation, they shall be ensured through artificial lighting and ventilation in accordance with the provisions of Part VIII, Building Service Section I, Lightning and Ventilation, National Building Code.
(4) In any residential hotel where toilets are provided with a mechanical ventilation system, the size of the ventilation shaft prescribed in this Regulation may be suitably relaxed by the Commissioner
DCPR-2034
41. Open Spaces within Building Plots/ Layout
(1) (a) Open spaces separate for each building or wing. -The open spaces required under these Regulations shall be separate or distinct for each building and where a building has two or more wings, each wing shall have separate or distinct open spaces as required under these Regulations;
Provided that if one of the wings does not depend for light and ventilation on the open space between the two wings, the said open space shall be the one required for the higher wing or one required for deriving the light and ventilation whichever is higher.
Open spaces to be provided for the full consumption of FSI-The open spaces to be left at the sides and rear shall relate to the height necessary to consume the full FSI permissible, for the occupancy in the zone.
(b)Manner of computing front open space/setback where the street is to be widened-If the building plot abuts any road which is proposed to be widened under the Development Plan or because of the prescription of regular lines of streets under the Mumbai Municipal Corporation Act, 1888, the front open space /road-side set back shall be measured from the resulting road widening line.
(c) The front open space shall be measured perpendicular to the road line. The open spaces for light and ventilation shall be measured perpendicular to the building line. The open spaces for dead wall shall be measured perpendicular to compound wall.
(2) Side and rear open space in relation to the height of the building for light and ventilation-
(i)Residential and Commercial Zones-
(a)The open spaces on all sides except the front side of a building shall be as follows:
Table A
| Sr. No. | Ht. of Building (H) | Side & rear marginal open space | Side & rear marginal open space | ||
| Plot up to 1000 sq. m or where average width/depth of plot is less than 20 m | Plot size more than 1000 sq. m and average width/depth of plot more 20 m | ||||
| Light & ventilation | Dead wall | Light & ventilation | Dead wall | ||
| 1 | Up to 32 m | Min - 3.6in case of Residential building & 4.5 m in case of commercial building subject to H/5 | 3.6 m | Min - 3.6in case of Residential building & 4.5 m in case of commercial building subject to H/4 | 3.6 m |
| 2 | More than 32 m & up to 70 m | H/5 subject to maximum 12 m | 6 m | H/4 subject to maximum 12 m | 6m |
| 3 | More than 70m & up to 120 m | ------------------ | |||