4.10.1The basement shall not be used for residential purposes.
4.10.2The construction of the basement shall be allowed by the Authority in accordance with the land use and other provisions specified under the Development Control Rules.
4.10.3The basement to be constructed within the building envelope and subject to maximum coverage on floor 1 (entrance floor) may be put to only the following uses:
a) Storage of household or other goods of ordinarily non-combustible material;
b) Strong rooms, bank cellars, etc;
c) Air-conditioning equipment and other machines used for services and utilities of the building; and
d) Parking spaces.
4.10.4 The basement shall have the following requirements:
a) Every basement shall be in every part at least 2.4 m in height from the floor to the underside of the roof slab or ceiling and with maximum height not more than 4.5m.
b) Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to byelaws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air-conditioning systems, etc;
c) The minimum height of the ceiling of any basement shall be 0.9m and the maximum, 1.2 m above the average surrounding ground level;
46
d) Adequate arrangements shall be made such that surface drainage does not enter the basement;
e) The walls and floors of the basement shall be watertight and be so designed that the effects of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given; and
f) The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors.
g) Basement in an individual plot touching the adjacent property shall be allowed subject to following:
Chapter 4
i) In all cases the owners shall have to indemnify the local body against any damage caused by her/him/them to the adjacent property (Appendix-B-1).
ii) In case the portion of the basement projecting out of the building line shall flush with the ground.
h) In case partition in the basement is allowed by the Authority, no compartment shall be less than 50.0 sq m. in area and each compartment shall have ventilation standards as laid down in sub-clause (ii), above separately and independently. The basement partition shall however, conform to the norms laid down by Fire Services.