3.4.1 Residential Use Zone
The residential areas are developed either as
a) Plotted development or
b) Group housing/flatted development.
The density pattern i.e. (high density, high medium density, low medium density or low density) are followed for working out the pattern of development with respect to:
i) Size of the plot
ii) Number of dwelling units on each plot
iii) Setbacks
iv) FAR
v) Number of storeys/ height of the building
The municipal and social infrastructure as per the norms and standards specified in the Master Plan shall be provided. The various sites/plots required for social and municipal infrastructure are to be indicated in the layout plans. The development norms for different use/activities and on different sizes of plots are
Chapter 3
Development Codes
applied for sanctioning of the plans. These are based on development control rules applicable to the city/town.
3.4.2 Buildings within the Residential Use Zone
Buildings for various uses/activities within the residential use zone forming part of the residential layout plan are to be constructed with the norms of the coverage, FAR, height and others as applicable to that size of a residential plot.
3.4.3 Residential Premises – Plotted Housing
The layout plans for residential scheme shall be formulated keeping in view:
i) that there should be sufficient daylight and fresh air in the habitable areas within the buildings, when constructed.
ii) that there would be protection against noise, dust and local hazards
iii) that there should be sufficient open space for various family needs and in accordance with the provisions of clause (4.26), (4.27) and (4.28).
iv) that the circulation and access is easy and is safe from accident point of view
v) that, as far as possible, the plots are of regular shape and size and
vi) these are logically arranged in a systematic manner so as to give a regular pattern of development in the form of row houses, detached and semi-detached houses and if necessary the regular bungalow type plots.
For low-income group, the minimum plot size should not be less than 100 sqm. However, the plot size may vary depending upon the type of the housing and general affordability of the people. The size of the plot would also depend on the number of dwelling units to be permitted on each plot. Normally, a plot should be built for two dwelling units on each plot. However, on bigger size plots, more than one dwelling unit per plot can be built. The following Table is suggested for different size of the plots applicable, ground coverage, FAR, height and number of dwelling units for a residential area:
| Plot Area (sqm) | Maximum Ground Coverage [%] | FAR | No. of DUs. | Maximum Height (M) Residential | Maximum Height (M)- Including stilt parking |
|---|---|---|---|---|---|
| 48.00 | 75 | 150 | 1 | 6 | 8.4 |
| Above 48 upto 60 | 75 | 150 | 2 | 6 | 8.4 |
| Above 60 upto 100 | 65 | 180 | 3 | 12 | 14.4 |
| Above 100 upto 250 | 65 | 180 | 3 | 12 | 14.4 |
| Above 250 upto 500 | 60 | 200 | 6 | 15 | 17.4 |
| Above 500 upto 1000 | 50 | 250 | 8 | 15 | 17.4 |
| Above 1000 upto 1500 | 50 | 250 | 8 | 15 | 17.4 |
| Above 1500 upto 3000 | 45 | 225 | 12 | 15 | 17.4 |
-
In the already developed plots the pattern of development should conform to the existing regulations.
-
Basement, if constructed, may be used for incidental use such as parking, servicing and household storage. It is not to be used as a dwelling unit or human habitation. For slope areas, floors below road level can be treated as Basement. Dwelling or human habitation can be permitted, provided three sides of the building are open and maintain Fire Safety norms (including minimum specified staircase with Fire Exit Facility) and as mention in clause 4.26 & 4.27. FAR of such Basement shall be calculated.
Apart from above ground level/road level, if there is road accessibility in lowest floor, such floor cannot be treated as basement when three sides are open and natural lit up. Further, height of the building shall be calculated from the approach road of the lowest floor/basement floor.
Chapter 3
Development Codes
-
The building height in mix-use is allowed up to 17.4-meter subject to zoning regulation and provisions of fire safety requirement norms and where stilt floors is to be constructed for parking the height may be increased to 17.4 meters.
-
Parking as per the prescribed norms should be provided with the plot or provision should be made in the layout plan without affecting the circulation pattern, hence FAR calculation is exempted where stilt floor is constructed.
-
50% of the open area of the plot should be used for proper landscaping and for plantation as prescribed norms of open space.
-
The minimum height of stilt parking is 2.4m.
-
The plinth height shall be excluded from maximum height of building.
-
The setbacks:
a) For upto 100 sqm plot ( i) 2.00 m (min) to the front (ii) 1.00 m (min) to the other sides
b) For above 100sqm plot (i) 3.00 m (min) to the front (ii) 1.20 m to the other sides.
c) For High rise 5.00 meters (min) to the front and 3.00 m to the other sides.
3.4.4Group Housing
The number of dwelling unit are calculated on the basis of the density pattern given in the development plan, taking into consideration a population of 4.5 persons per dwelling unit.
Minimum size of the plot -3000 sqm
Maximum ground coverage -35%
Maximum FAR - 200
In hilly Areas -5000 sqm
Maximum ground coverage -40%
Maximum FAR -200
Number of dwelling units -To be calculated on the basis of the net plot area of a particular
3.4.5 Resettlement and Slum in-situ upgradation
i) Maximum net density 250 tenements per hectare.
ii) Plot size-minimum 25sqm. However, it may be reduced to 18sqm with 100% coverage provided an area @ 7sqm per plot/tenement is clubbed with the cluster open space.
iii) Path ways: (a) 2.00 m upto 30.00m in length (b) 3.00 m upto 50.00m in length Note:
-
Basement, if constructed is to be used for parking, services and for essential household storage and for providing facilities without counting in FAR.
-
The quantum of basement may vary between 33 % to 50% of the plot area.
-
Above unit subject to change in hilly areas.
3.4.5.1 Row Housing
i) Maximum width of the plot is restricted to 8.00 meters.
ii) Minimum front setback is 2.00 meters and rearside 1 meter for service lines.
iii) Maximum ground coverage is 75%
iv) Maximum Height 9.00 meters plus stilt 2.40 meter.
v) Should be located in Residential Zone.
vi) When the site fronts is situated on two streets, the frontage would be street having larger width. However, in such cases of natural topographic condition or other factor the frontage may be considered on other side.
3.4.6Low Income Housing
The minimum plot size shall not be less than 48 sqm.
i) It is recommended to provide cluster housing instead of single room dwelling.
ii) The minimum plot size with ground coverage not exceeding 75%, shall be minimum 48sqm.
iii) Size of room: Every dwelling unit should have at least two habitable rooms, first room of minimum 9sqm and width of 2.5m. Other room shall be min 6.5sqm with minimum width of 2.1m provided the total area of both the rooms shall not be less than 15. sqm.
Chapter 3