Floor Area Ratio (FAR) =
Plot Area
-
“Fire and/or Emergency Alarm System”- Fire alarm system comprises of components for manually or automatically detecting a fire, initiating an alarm of fire and initiating other actions as appropriate.
-
“Fire Hazard Industries”-
i) "Low Fire Hazard Industries" includes engineering industries using/processing or assembling non-combustible materials i.e. lathe machines, steel works, steel components etc.
ii) "Moderate Fire Hazard Industries" includes industries using / processing combustible materials but not flammable liquid etc., plastic industries, rubber, and PVC industries, textile, paper, furniture, flour mills etc.
iii) "High Fire Hazard Industries" includes industries using/processing flammable liquids, gases, chemicals petroleum products, plastic or thermo setting group etc.
-
“Fire Lift”- Means a special lift designed for the use of fire service personnel in the event of fire or other emergency.
-
“Fire Proof Door”- Means a door or shutter fitted to a wall opening, and constructed and erected with the requirement to check the transmission of heat and fire for a period.
-
“Fire Pump”- Means a machine, driven by external power for transmitting energy to fluids by coupling the pump to a suitable engine or motor, which may have varying outputs/capacity but shall be capable of having a pressure of 3.2 kg/cm2 at the topmost level of multi-storey or high rise building.
-
“Fire Pump-Booster Fire Pump”- Means a mechanical/electrical device that boots up the water pressure at the top level of a multi-storeyed / high-rise building and which is capable of a pressure of 3.2 kg/cm2 at the nearest point.
Chapter 1
[DEFINITIONS
- “Fire Resistance”- Fire resistance is a property of an element of building construction and is the measure of its ability to satisfy for a stated period some or all of the following criteria:
a. resistance to collapse,
b. resistance to penetration of flame and hot gases, and
c. resistance to temperature rise on the unexposed face up to a maximum of 180°C and/or average temperature of 150°C.
Fire Resistance Rating -The time that a material or construction will withstand the standard fire exposure as determined by fire test done in accordance with the standard methods of fire tests of materials/structures.
-
“Fire Separation”- Means the distance in meters measured from any other building on the site or from another site, or from the opposite side of a street or other public space to the building.
-
“Fire Service Inlet”- Means a connection provided at the base of a building for pumping up water through in built fire-fighting arrangements by fire service pumps in accordance; with the recommendation of the Director Fire Services.
“Fire Tower”- Means an enclosed staircase that can only be approached from the various floors through landings or lobbies separated from both the floor area and the staircase by fire resistant doors and open to the outer air.
-
Fire Resisting Building”- means a building in which material, which has, appropriate degree of fire resistance is used.
-
“Footing”- A foundation unit constructed in brickwork, stone masonry or concrete under the base of a wall or column for the purpose of distributing the load over a larger area.
-
“Foundation”- A substructure supporting an arrangement of columns or walls in arrow or rows transmitting the loads to the soil.
-
“Front Air Plane”- The plane contained between the ground in front of the building and the straight lines drawn downwards and outwards from the line of intersection of the outer surface of any front wall of the building with the roof perpendicular to that line, and at an angle of 63-1/2 degrees to the horizontal;
Note: The 63-1/2 degrees’ angle has a tangent of 2:1 so that if the ground is the level, the air plane reaches the ground at a distance from the exterior wall equal to half the height of the above level of that ground.
-
“Gallery"- An intermediate floor or platform projecting from a wall of an auditorium or a hall providing extra floor area, and/additional seating accommodation and includes the structures provided for seating in stadia.
-
“Garage-Private”- A building or a portion thereof designed and used for the parking of vehicle.
-
“Garage-Public” - A building or portion thereof, designed other than as a private garage, operated for gain, designed and/or used for repairing, servicing, using, selling or storing or parking motor driven or other vehicles.
-
“Ground Floor”- shall mean storey, which has its floor surface nearest to the ground around the building.
-
“Group Housing”- means a building unit constructed or to be constructed with one or more floors having more than two dwelling units having common service facilities where land is owned jointly (as in the case of co-operative societies or the public agencies, such as local authorities or housing boards, etc) and the construction is undertaken by one Agency.
“Habitable Room”- A room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used as a living room, but not including bathrooms, water-closet compartments, laundries, serving and store pantries, corridors, cellars, attics, and spaces that are not used frequently or during extended periods.
Chapter 1
[DEFINITIONS
-
“Illuminated Exit Signs”- A device for indicating the means of escape during normal circumstances and power failure.
-
“Jhamp”-A downward, vertical or sloping projection hanging below any horizontal projection like balcony, canopy, verandah, passage etc, to provide protection from direct sun and rain.
-
“Jhot” -A strip of land permanently left open for drainage purposes. It is not to be used as an access way or a street and is not to be included as a part of setbacks.
-
“Katra or Chawl”-A building so constructed as to be suitable for living in separate tenements each consisting a single room, or of two, but not of more than two rooms and with common sanitary arrangements.
-
“Layout Plan” – means a Plan indicating configuration and sizes of all Use Premises. Each Use Zone may have one or more than one Layout Plan depending upon the extensiveness of the area under the specific Use Zones and vice versa. A layout plan shall have at least two use premises (apart from Recreational, utilities and transportation) and a minimum area of 1 hectare.
-
“Ledge or Tand”- A shelf-like projection, supported in any manner whatsoever, except by means of vertical supports within a room itself but not having projection wider than 1 m.
-
“Licensed Architect / Town Planner / Engineer / Supervisor / Plumber”- Qualified professionals who have been registered with the Authority as per the Qualification and competence given in Appendix ‘E’ / by the body governing such profession and therefore possess the license to provide professional services in Building construction.
-
“Lift”- An appliance designed to transport persons or materials between two or more levels in a vertical or substantially vertical direction by means of a guided car or platform. The word ‘elevator’ is also synonymously used for ‘lift’.
-
“Lobby”- means a covered space in which all the adjoining rooms open.
-
“Loft”- An intermediate floor between two floors or a residual space in a pitched roof above normal level constructed for storage with maximum clear height of 1.5 meters.
-
“Light Plane”- The plane lying between the line of intersection of the floor of any room in a building with the outer surface or an exterior wall of the building and the straight lines drawn upwards and outwards from those lines drawn upward and outwards from lines perpendicular thereto an at an angle of 63 1/2 º to the horizontal.
Note:For the purpose of the definition of light plane, the outer surface of any verandah abutting on an interior or side open space shall be considered to be the exterior wall of the building.
-
“Masonry” - An assemblage of masonry units properly bound together by mortar.
-
“Masonry Unit” - A unit whose net cross-sectional area in every plane parallel to the bearing surface is 75% or more of its gross cross-sectional area measured in the same plane. It may be either of clay, brick, stone, concrete, sand lime brick or any other construction material.
-
“Master Plan”- A Master Plan formulated under any relevant Act (Town and Country Planning or Development Act or Municipal Act) for any town, approved and notified by the State Government.
-
“Means of Escape”- An escape route provided in a building for safe evacuation of occupants.
-
“Mezzanine Floor”- An intermediate floor between two floors of any storey forming an integral part of floor below. The minimum height of Mezzanine Floor shall be 2.4 meter.
-
“Mumty or Stair Cover”- A structure with a covering roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation.
-
“MCB/ELCB”- Devices for tripping of electrical circuits in event of any fault in the circuit/installation.
-
“Non Combustible Material”- A material which is not liable to burn or add heat to afire when tested for combustibility in accordance with the latest code of Bureau of Indian Standards Method of Test for combustibility of Building Materials.
Chapter 1 [DEFINITIONS
- “Occupancy or use”:- The principal occupancy/ use for which a building or a part of a building is intended to be used. For the purposes of classification of a building according to occupancy, an occupancy shall be deemed to include the subsidiary occupancies which are contingent upon it.
“Mixed occupancy” buildings being those in which more than one occupant is present in different portions of the buildings.
-
“Online Building Permission System (OBPS)”- A computerized, automated and digital system of building permit serves the citizen to a transparent, speedy, hassle free and user friendly procedure for building construction permission.
-
“Open space”- An area forming an integral part of a site left open to the sky.
-
“Owner”-Person or body having a legal interest in land and/or building thereon. This includes free holders, leaseholders or those holding a sub-lease which both bestows a legal right to occupation and gives rise to liabilities in respect of safety or building condition.
In case of lease or sub-lease holders, as far as ownership with respect to the structure is concerned, the structure of a flat or structure on a plot belongs to the allottee/ lessee till the allotment/lease subsists.
-
“Parapet”- A low wall or railing built along the edge of a roof or a floor.
-
“Parking space”- An enclosed or unenclosed covered or open area sufficient in size to park vehicles. Parking spaces shall be served by a driveway connecting them with a street or alley and permitting ingress and egress of vehicles.
-
“Partition”- An interior non-load bearing barrier, one storey or part-storey in height.
-
“Partition Wall” includes-
i) A wall forming part of a building and being used or constructed to be used in any part of the height or length of such wall for separation of adjoining buildings belonging to different owners or constructed or adopted to be occupied by different persons; or
ii) A wall forming part of a building and standing in any part of the length of such wall, to a greater extent than the projection of the footing on one side or ground of different owners.
- “Permanent Open Air Space”- Air space permanently open:
(i) If it is a street.
(ii) If its freedom from encroachment is protected by any law or contract ensuring that the ground below it is either a street or is permanently and irrevocably appropriated as an open space.
-
“Permission or Permit”- A valid permission or authorization in writing by the competent Authority to carryout development or a work regulated by the Bye-Laws.
-
“Plinth”- The portion of a structure between the surface of the surrounding ground and surface of the floor immediately above the ground.
-
“Plinth Area”- The built up covered area measured at the floor level of the basement or of any storey.
-
“Plot/ Site”- A parcel or piece of land enclosed by definite boundaries.
-
“Plotted Development” – Type of development layout wherein a stretch of developed land is divided into regular sized plots for uniform controlled building volumes.
-
“Porch”- A covered surface supported on pillars or otherwise for the purpose of a pedestrian or vehicular approach to a building.
-
"Prohibited area" means any area specified or declared to be a prohibited area under section 20A of the AMASR Act, 2010.
-
“Protected monument” means an ancient monument which is declared to be of national importance by or under the AMASR Act, 2010.
-
"Regulated area" means any area specified or declared under section 20B under the AMASR Act, 2010.
-
“Retention Activity”- An activity or use which is allowed to continue, notwithstanding its non-conforming nature in relation to the use permitted in the adjoining or surrounding area.
Chapter 1 [DEFINITIONS
-
“Road/Street”- Any highway, street, lane, pathway, alley, stairway, passageway carriageway, footway, square, place or bridge whether a thorough-fare or over which the public have a right of passage or access or have passed and have access uninterruptedly for specified period, whether existing or proposed in any scheme and includes all bends, channels, ditches, storm water drains, culverts sidewalks, traffic islands, roadside trees and hedges, retaining walls fences, barriers and railing within the street lines.
-
“Road/Street Level or Grade”- The officially established elevation or grade of the centerline of street upon which a plot fronts, and if there is no officially established grade, the existing grade of street at its mid-point.
-
“Road/Street Line” -The line defining the side limits of a road/street.
-
“Road Width or Width of Road/Street” - The whole extent of space within the boundaries of a road when applied to a new road/street as laid down in the city survey or development plan or prescribed road lines by any act of law and measured at right angles to the course or intended course of direction of such road.
-
“Row Housing” -A row of houses with only front, rear and interior open spaces.
-
“Rear Air Plane” - The plane contained between the ground behind the building and the straight line drawn downwards and outwards from the line of intersection of the outer surface of any rear wall of the building with the roof perpendicular to that line and at an angle 63-1/2 degree to the horizontal.
-
“Room Height”- The vertical distance measured from the finished floor surface to the finished ceiling surface. Where a finished ceiling is not provided, the underside of the joists or beams or tie beams shall determine the upper point of measurement for determining the head room.
-
“Service Road”- A road/lane provided at the front, rear or side of a plot for service purpose.
-
“Set-back Line”- A line usually parallel to the plot boundaries or center line of a road and laid down in each case by the Authority or as per recommendations of Master/Zonal Plan, beyond which nothing can be constructed towards the plot boundaries excepting with the permission of the Authority.
-
“Settlement”- A human settlement, whether urban or rural in character. It includes habited villages, towns, townships, cities and the areas notified under the control of the Authority.
-
“Site”- See “Plot”
-
“Site Corner”- A site at the junction of and fronting on two or more intersecting roads or streets.
-
“Site Depth”- The mean horizontal distance between the front and rear site boundaries.
-
“Site Plan” – A detailed Plan showing the proposed placement of structures, parking areas, open space, landscaping, and other development features, on a parcel of land, as required by specific sections of the development code.
Chapter 1
[DEFINITIONS
(ii) To re-erect any building of which portions above the plinth level have been pulled down, burnt or destroyed.
-
“Un-authorized Construction”- means the erection or re-erection, addition or alternations which is not approved or sanctioned by the Authority.
-
“Underground/Overhead Tank”- An installation constructed or placed for storage of water.
-
“Ventilation”- Supply of outside air into, or the removal of inside air from an enclosed space.
a. Natural Ventilation - Supply of outside air into a building through window or other openings due to wind outside and convection effects arising from temperature or vapour pressure differences (or both) between inside and outside of the building.
b. Positive Ventilation - the supply of outside air by means of a mechanical device, such as a fan.
c. Mechanical Ventilation - Supply of outside air either by positive ventilation or by infiltration by reduction of pressure inside due to exhaust of air, or by a combination of positive ventilation and exhaust of air.
-
“Verandah” — A covered area with at least one side open to the outside with the exception of 1m high parapet on the upper floors to be provided on the open side.
-
“Water Closet (W.C)”- A water flushed plumbing fixture designed to receive human excrement directly from the user of the fixture. The term is used sometimes to designate the room or compartment in which the fixture is placed.
-
“Window”- An opening to the outside other than a door, which provides all or part of the required natural light or ventilation or both to an interior space and not used as a means of egress/ingress.
-
“Zonal Plan”- A plan detailing out the proposals of Master Plan and acting as a link between Master Plan and the Layout Plan. It may contain a site plan and land use plan with approximate location and extent of land uses such as public & semipublic buildings/works, utilities, roads, housing, recreation, industry, business, markets, schools, hospitals open spaces etc. It may also specify standards of population density and various components of development of the zone.
Chapter 2