The provisions contained in Master Plan/Zonal Plan/Development Code or as per the Urban and Regional Development Plan Formulation and Implementation Guidelines, 2014 shall apply and where these are silent on such issues or which require interpretation the norms as decided by the Authority, shall apply. The provisions include but are not limited to the use/ activity of premises, ground coverage, FAR, set-backs, open space, height, density and number of dwelling units and parking standards for Residential premises on plotted development, Group housing, Resettlement colonies, Slums, In-situ upgradation, Non-residential premises.
The permission of uses/use activities in use premises shall permitted in accordance with provisions of Master Plan/Zonal Plan/ Local Area Plan/ Layout Plan.
The object of these regulations is to provide control for building/buildings within use premises excluding the internal arrangement, which is covered and controlled by Building Bye-Laws.
Notes:-The premises for which building regulations have not been given shall be examined by the Authority on the basis of actual requirements and other relevant factors.
i) Wherever there is a need for relaxation in height for achieving urban form, the same may be permitted with the recommendation of the Authority.
ii) The provision of minimum setbacks for different sizes of plots for all categories of the plots shall be as per the Master Plan/Development Plan or as per simplified Development Promotion Regulations of the Urban and Regional Development Plans Formulation and Implementation (URDPFI) Guidelines.
3.1Flexible FAR
3.1.1Additional FAR
Additional FAR, as provided in the Master Plan may also be examined with a view to provide flexibility and also to utilize the scarce urban land optimally. Flexible range of FAR on a site may be based upon its Additional FAR Factor which is a product of ‘creativity’ and ‘context’. Creativity can be defined by design parameters such as urban form, parking provision, pedestrian safety, concern for the poor through induced informal activities, and provisions for evacuation during an emergency due to disaster (for example, Delhi falls in the Zone 5). It also includes the impact of the design on essential services and environment. As a principle, the additional FAR should not result in a negative impact on the essential services and environment.
Locational attributes, of the site being assigned additional FAR, refer to its location with respect to land use as given in the approved Master/Zonal/Layout Plan (as the case may be), accessibility, level of congestion on the approach road and nearness to a heritage building if any.
Additional FAR Factor
= Creativity x context
= Design parameters x Locational attributes
= (a+b+c+d+e) m.n.o.p.
x + y
Where, a = Parking provision value
b = Disaster emergency provision value
c = Urban Form value
Chapter 3
Development Codes
d = Pedestrian Safety value
e = Induced informal activities value
x = Impact on essential services value
y = Impact on environment value
m = Land Use value
n = Accessibility (Right of way of the approach road) value
o = Congestion (Mobility index in terms of travel speed) value
p = Heritage Value
3.1.2 Purchasable FAR
Provision of purchasable FAR in Group Housing, Commercial, Institutional, and Industrial, Sport and amusement complex, recreational greens and Low Density Sports plot may be considered, where:
(i) The Plots exist on ’24 meters and above’ wide road.
(ii) The construction has not started, or
(iii) The allottee wants to construct a new additional building within the limits of permissible ground coverage, or
(iv) The allottee wants to construct new building on the vacant plot, or
(v) The allottee has already constructed building within purchasable FAR limits, or
(vi) Purchasable FAR may be allowed on minimum 18.00meters road width and above road width for institutional and industrial use.
Explanation: The Purchasable FAR shall be allowed up to the maximum limit of the applicable FAR in the Building Regulations.
Purchasable may FAR be allowed with the following provision/ conditions:
(i) No construction shall be allowed beyond the limit of maximum permissible ground Coverage.
(ii) Parking facilities shall be provided within the plot as per the provisions of the building bylaws.
(iii) No objection certificate from the Airport Authority of India/ Competent Authority shall be obtained for the height of the building.
(iv) Structure design duly checked and verified by the I.I.T/ N.I.T./Government Engineering College shall be submitted along with the proposal in case where additional floors are being proposed.
(v) No objection certificate for Fire Safety and Environmental Clearance shall be obtained from the Competent Authorities.
(vi) Purchasable FAR shall be applicable only on the basis of assessment of planned and available physical infrastructure.
(vii) Use of purchasable FAR shall be governed by the terms and conditions of lease deed.
(viii) In case where purchasable FAR is allowed, the Authority shall permit increase in the height of building as per requirement.
(ix) Additional proportionate residential units shall be allowed on purchasable FAR for Group Housing.
(i) Purchasable FAR is an enabling provision. It shall not be allowed to any Allottee as a matter of right.
(ii) With the consideration of Traffic density, conditions of approach road, availability of physical infrastructure, distance from the protected area and heritage sites or in the light of planning the Authority may identify the zones/ areas where purchasable FAR shall not be allowed.
(iii) In case of mixed land use permitted in any pocket/plot:
Permissible FAR for various uses shall be as applicable for respective use including the purchasable FAR. The total FAR in the pocket/plot shall be subject to the overall permissible FAR for the pocket/plot. Purchasable FAR shall be calculated on the basis of the FAR of the individual uses within that pocket/plot.
Chapter 3
Development Codes
3.1.3 Floating FAR
The Authority shall allow development by restricting / regulating height of the building width of abutting road and plot sizes. This method is based on the carrying capacity analysis of the infrastructure planned. In keeping with the norm in the provision of infrastructure adjusted to the percentage, plot owners shall be permitted to use the additional FAR on payment basis.
Basis for increasing FAR: Carrying Capacity analysis tool is useful to rationalize fixation of FAR including increase in given FAR. Two major determining factors should be considered:
1. V/C (V= volume, C= capacity)
V/C: optimum level is 0.8; it can be relaxed upto 0.9. Above 0.9 is dysfunctional and 1.0 is not desirable.
2. LPCD of piped water supply
The planned LPCD should be as per the minimum of norm i.e. 135 liters. However, the density is to be capped by the Development/ Master Plan as per the threshold.
Note: Assignment of Values for flexible FAR and other calculations may be referred from URDPFI Guidelines, 2014
3.2Development norms and standards for hill towns
The suggested norms and standards are only indicative and can be suitably modified depending upon the local conditions both physical and environment. In hill areas, the space standards are affected by the topography and environment and therefore the following factors shall be considered while setting norms in such areas:
i) Exposure to sunlight
ii) Degree of slopes and accessibility in the form of distance traveled.
iii) Basic needs of the people
iv) The conservation principle.
v) Alternative modes of transportation Communication network.
vi) Mobile facilities and emergency facilities.
3.3Parking standard
Parking space shall be provided for different types of development as per norms given in Master Plan/Development Plan or as given below:
3.3.1 The following Table 3.1 may be referred to for deciding the parking norms for different use zone/activities only minimum required value of ECS and NOT a range should be specified in the development plan. It can be changed in subsequent plan depending upon need based upon local vehicle ownership, mass transportation and consequent parking needs.
Table 3.1Parking standards
S.No.
Land use
Parking Standards
Remark
1
Residential
Residential Plot-Plotted Housing
1.5ECS in plot size 100-300 sqm 2.5 ECS in plot size 300-500 sqm& Additional 1ECS for every per 100 sqm.
3.3.2 Multi Storeyed parking
Special permission shall be sought for development of buildings specifically for parking. Permission shall be granted based on width of road, requirement for parking space, FAR available and other parameters as specified by the competent authority.
Minimum Area of plot: 2000 sqm
Hilly Area 1000 sqm
Minimum number of car parking spaces: 50.00 sqm
Development of such parking lots may be undertaken by offering tradable FAR to the developer in lieu of development of parking lots which may be surrendered to competent authority on completion.
28
3.3.3 Stilt Parking
Mandatory stilt floor construction for residential apartment, mixed building, coaching institute, training center, Nursing Home, Poly Clinic, Hotels, Hostels, Paying Guest, Assembly Buildings and other related buildings to accommodate parking requirement as per parking standard given at Table 3.1.
3.4Specific premises
3.4.1 Residential Use Zone
The residential areas are developed either as
a) Plotted development or
b) Group housing/flatted development.
The density pattern i.e. (high density, high medium density, low medium density or low density) are followed for working out the pattern of development with respect to:
i) Size of the plot
ii) Number of dwelling units on each plot
iii) Setbacks
iv) FAR
v) Number of storeys/ height of the building
The municipal and social infrastructure as per the norms and standards specified in the Master Plan shall be provided. The various sites/plots required for social and municipal infrastructure are to be indicated in the layout plans. The development norms for different use/activities and on different sizes of plots are
Chapter 3
Development Codes
applied for sanctioning of the plans. These are based on development control rules applicable to the city/town.
3.4.2 Buildings within the Residential Use Zone
Buildings for various uses/activities within the residential use zone forming part of the residential layout plan are to be constructed with the norms of the coverage, FAR, height and others as applicable to that size of a residential plot.
3.4.3 Residential Premises – Plotted Housing
The layout plans for residential scheme shall be formulated keeping in view:
i) that there should be sufficient daylight and fresh air in the habitable areas within the buildings, when constructed.
ii) that there would be protection against noise, dust and local hazards
iii) that there should be sufficient open space for various family needs and in accordance with the provisions of clause (4.26), (4.27) and (4.28).
iv) that the circulation and access is easy and is safe from accident point of view
v) that, as far as possible, the plots are of regular shape and size and
vi) these are logically arranged in a systematic manner so as to give a regular pattern of development in the form of row houses, detached and semi-detached houses and if necessary the regular bungalow type plots.
For low-income group, the minimum plot size should not be less than 100 sqm. However, the plot size may vary depending upon the type of the housing and general affordability of the people. The size of the plot would also depend on the number of dwelling units to be permitted on each plot. Normally, a plot should be built for two dwelling units on each plot. However, on bigger size plots, more than one dwelling unit per plot can be built. The following Table is suggested for different size of the plots applicable, ground coverage, FAR, height and number of dwelling units for a residential area:
Table 3.2Building Control in Residential Premises
Plot Area (sqm)
Maximum Ground Coverage [%]
FAR
No. of DUs.
Maximum Height (M) Residential
Maximum Height (M)- Including stilt parking
48.00
75
150
1
6
8.4
Above 48 upto 60
75
150
2
6
8.4
Above 60 upto 100
65
180
3
12
14.4
Above 100 upto 250
65
180
3
12
14.4
Above 250 upto 500
60
200
6
15
17.4
Above 500 upto 1000
50
250
8
15
17.4
Above 1000 upto 1500
50
250
8
15
17.4
Above 1500 upto 3000
45
225
12
15
17.4
In the already developed plots the pattern of development should conform to the existing regulations.
Basement, if constructed, may be used for incidental use such as parking, servicing and household storage. It is not to be used as a dwelling unit or human habitation. For slope areas, floors below road level can be treated as Basement. Dwelling or human habitation can be permitted, provided three sides of the building are open and maintain Fire Safety norms (including minimum specified staircase with Fire Exit Facility) and as mention in clause 4.26 & 4.27. FAR of such Basement shall be calculated.
Apart from above ground level/road level, if there is road accessibility in lowest floor, such floor cannot be treated as basement when three sides are open and natural lit up. Further, height of the building shall be calculated from the approach road of the lowest floor/basement floor.
Chapter 3
Development Codes
The building height in mix-use is allowed up to 17.4-meter subject to zoning regulation and provisions of fire safety requirement norms and where stilt floors is to be constructed for parking the height may be increased to 17.4 meters.
Parking as per the prescribed norms should be provided with the plot or provision should be made in the layout plan without affecting the circulation pattern, hence FAR calculation is exempted where stilt floor is constructed.
50% of the open area of the plot should be used for proper landscaping and for plantation as prescribed norms of open space.
The minimum height of stilt parking is 2.4m.
The plinth height shall be excluded from maximum height of building.
The setbacks:
a) For upto 100 sqm plot ( i) 2.00 m (min) to the front (ii) 1.00 m (min) to the other sides
b) For above 100sqm plot (i) 3.00 m (min) to the front (ii) 1.20 m to the other sides.
c) For High rise 5.00 meters (min) to the front and 3.00 m to the other sides.
3.4.4Group Housing
The number of dwelling unit are calculated on the basis of the density pattern given in the development plan, taking into consideration a population of 4.5 persons per dwelling unit.
Minimum size of the plot -3000 sqm
Maximum ground coverage -35%
Maximum FAR - 200
In hilly Areas -5000 sqm
Maximum ground coverage -40%
Maximum FAR -200
Number of dwelling units -To be calculated on the basis of the net plot area of a particular
3.4.5 Resettlement and Slum in-situ upgradation
i) Maximum net density 250 tenements per hectare.
ii) Plot size-minimum 25sqm. However, it may be reduced to 18sqm with 100% coverage provided an area @ 7sqm per plot/tenement is clubbed with the cluster open space.
iii) Path ways: (a) 2.00 m upto 30.00m in length (b) 3.00 m upto 50.00m in length Note:
Basement, if constructed is to be used for parking, services and for essential household storage and for providing facilities without counting in FAR.
The quantum of basement may vary between 33 % to 50% of the plot area.
Above unit subject to change in hilly areas.
3.4.5.1 Row Housing
i) Maximum width of the plot is restricted to 8.00 meters.
ii) Minimum front setback is 2.00 meters and rearside 1 meter for service lines.
iii) Maximum ground coverage is 75%
iv) Maximum Height 9.00 meters plus stilt 2.40 meter.
v) Should be located in Residential Zone.
vi) When the site fronts is situated on two streets, the frontage would be street having larger width. However, in such cases of natural topographic condition or other factor the frontage may be considered on other side.
3.4.6Low Income Housing
The minimum plot size shall not be less than 48 sqm.
i) It is recommended to provide cluster housing instead of single room dwelling.
ii) The minimum plot size with ground coverage not exceeding 75%, shall be minimum 48sqm.
iii) Size of room: Every dwelling unit should have at least two habitable rooms, first room of minimum 9sqm and width of 2.5m. Other room shall be min 6.5sqm with minimum width of 2.1m provided the total area of both the rooms shall not be less than 15. sqm.
Chapter 3
Development Codes
3.5Non-Residential Premises
3.5.1 Foreign Mission
Maximum Ground Coverage
35%
Maximum Floor Area Ratio
175
Maximum Height
15.00m
Other Controls:
i. If basement/stilt are used for parking/services shall not be counted in FAR.
i) Basement upto the building envelope to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR.
ii) Further, for Risk based approval of types of Warehouses / IFC refer clause 13.5, Table 13.4
3.6.9 Petrol Pumps
The following regulations are recommended for locating the petrol pump cum service stations-
i) Minimum distance from the road intersections. a) For minor roads having less than 18m RoW 30m b) For major roads having RoW 18m or more 45m
ii) The minimum distance of the property line of pump from the center line of the Road should not be less than 15 meters on roads having less than 30 m. R/W. In case of roads having 30 m. or more R/W, the R/W of the road should be protected.
iii) Plot Size
a) Only filling stations 30m x 17m and small size 18m x 15m (for two and three wheelers).
b) Filling-cum-service station minimum size 36 m. x 30 m. and maximum 45m x 33m.
c) Frontage of the plot should not be less than 30m.
d) Longer side of the plot should be the frontage.
iv) New Petrol Pump shall not be located on roads having less than 30 m. R/W.
Other Controls:
a) Filling-cum-service station size 36m x 30m and 45m x 33m)
i. Ground coverage : 20%
ii. FAR : 20
iii. Maximum Height : 6m
iv. Canopy : (Equivalent to permissible ground coverage within setback line)
v. Front Setback : Min. 6m
32
b) Filling station (size 30m x 17m and 18m x 15m)
i. Ground Coverage : 10 %
ii. FAR : 10
iii. Maximum Height : 6m
iv. Canopy (Equivalent to permissible ground coverage within setback line)
v. Front Setback : Min. 3m
Chapter 3
Development Codes
c) Other Regulations
i) Shall be approved by Explosives/Fire Deptt.
ii) Ground coverage will exclude canopy area.
iii) Mezzanine if provided will be counted in FAR
iv) Wherever the plot is more than 33 m. x 45 m. development norms shall be restricted to as applicable to the size i.e. 33 m. x 45 m. both in urban and rural areas.
d) Compressed Natural Gas (CNG) Mother Station
i) Plot Size (Max.) 36 m. x 30 m.
ii) Maximum ground coverage 20%
iii) Maximum Height 4.5 m. (single storey)
iv) Building Component Control room/office/Dispensing room, store, pantry and W.C.
3.6.10 Hotels/Lodge/Motels/Resorts
Sl. No.
Plot Size (Sq m.)
Maximum Ground Coverage
FAR
Height
1.
250 to below 500
60%
250
15.00
2.
500 to below 1000
50%
250
NR
3.
1000 to below 1500
50%
300
NR
4.
Above 1500
40%
300
NR
Other Controls:
i) 5% of the FAR can be used the commercial space related to hotel function.
ii) Basement(s) up to the building envelope to the maximum extent of plot area shall be allowed and if used for parking and services should not be counted in FAR.
iii) Stilt parking shall be mandatory for plot size 250 to below 500 sqm
3.6.11 Motels
Motels are permitted in Rural Zone/ Green Belt and in commercial zones on National Highways and Inter-State roads. The following norms and building standards are recommended.
Maximum Ground Coverage
35%
Maximum FAR
200.00
33
Basement equivalent to the ground coverage shall be allowed free of FAR to the extent necessary for air conditioning plant, filtration plant, electric sub- station, parking and other essential services.
Parking space shall be provided on a minimum scale of 2 ECS per 100 sqm. of floor area, including the provision made in this regard in the basement.
Retail and service shops shall be limited to a maximum of 5% of the floor area.
3.6.12 Resorts
Resorts are permitted in Urban Areas/Rural Zone/ Green Belt and in commercial zones on National Highways and Inter-State roads. The following norms and building standards are recommended.
Maximum Ground Coverage
35%
Maximum FAR
150
Maximum Height
12m
Basement equivalent to the ground coverage shall be allowed free of FAR to the extent necessary for air conditioning plant, filtration plant, electric sub- station, parking and other essential services.
Parking space shall be provided on a minimum scale of 2.0 ECS per 100 sq m. of floor area, including the provision made in this regard in the basement.
Retail and service shops shall be limited to a maximum of 5% of the floor area.
Chapter 3
Development Codes
3.6.13 Service Apartments
Minimum Plot Area
250 sqm
Maximum ground coverage
50%
Maximum FAR
200
Note: -Parking space shall be provided on a minimum scale of 2 ECS per 100 sq m. of floor area, including the provision made in this regard in the basement.
3.7Industrial Plot
3.7.1 Flatted Group Industry and Service Centre
Minimum plot size
2000 sqm
Maximum Ground Coverage
33.33%
Maximum Floor Area Ratio
120
Maximum height
15m
Other Controls:
i) Basement upto the building envelope line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR.
3.7.2 Light and Service Industry
Sl. No.
Plot Size (Sq m.)
Maximum Ground Coverage
Maximum FAR
Maximum height in (m)
Plains
Hills
Plains
Hills
1.
Less than 400
60%
125
100
12
9
2.
Above 400 & upto 4000
50%
125
100
12
12
3.
Above 4000 & upto 12000
45%
125
100
12
12
4.
Above 12000
40%
100
75
12
9
Other Controls:
Maximum floors allowed shall be basement, ground floor and first floor; basement should be below ground floor and to the maximum extent of ground coverage shall be counted in FAR. In case the basement is not constructed, the permissible FAR can be achieved on the second floor.
ii) In case of roof trusses, height of buildings could be adjusted/ relaxed.
3.7.3 Extensive Industry
Sl. No.
Plot Size (Sqm.)
Maximum Ground Coverage
Maximum FAR
Maximum height (in meter)
Plains
Hills
1.
400 to 4000
50%
100
75
9
2.
Above 4000 & upto 12000
45%
90
60
9
3.
Above 12000 & upto 28000
40%
90
50
9
4.
Above 28000
30%
60
45
9
Other controls:
34
i) Single Storey building with basement is allowed. Basement shall be below the ground floor and the maximum extent of ground coverage and shall be counted in FAR.
ii) In case of roof trusses, height of building could be adjusted/relaxed.
i) A new planned industrial area to have minimum 100-300 sqm size of plot & its width shall not be <15m.
ii) For industrial plots upto 1000 sqm, 5% of the total area shall be reserved as amenity open space which shall also serve as general parking space. When such amenity open space exceeds 1500 sqm, the excess area could be utilized for construction of buildings for banks, canteen, welfare centre and such other common purposes.
Chapter 3
Development Codes
iii) For industrial plots more than 1000 sq m, 10% of the total area to be reserved as amenity/ open space to a maximum of 25 sqm.
3.8Transportation
SI. No.
Use Premises
Development Controls
Area under Operation (%)
Area under Building (%)
FAR
Floor area can be utilized for passenger accommodation
Note: -The FAR is to be calculated on the Building plot. Area under Bus Shelter not to be included in FAR.
i) The space on first and second floor shall be essentially used for public services like post office, police‐post and other essential services.
ii) Bus queue shelters are not to be included in the coverage and FAR.
iii) In order to integrate the supporting commercial uses around the transportation zone, FAR can be more for promoting mixed use.
iv) The maximum height of the Bus Terminus Building shall be restricted to 12M.
Parking Area of - 18.00 sqm for open parking - 28.00 sqm for stilt parking - 32.00sqm for basement.
Residential Plot - Group Housing
1.5 ECS for 300 sqm built up area Additional 1ECS for every 100sqm.
-
Guest House / Lodging & Boarding House / Dharamshala
1.5 ECS for 100sqm built up area
-
2
Commercial Centers
-
Convenience Shopping Centre/Local Shopping Centre/Local Level Commercial areas
0.5 - 1.5 ECS/100 sqm of floor area
Community Centre / Non-hierarchical Commercial Centre
2 ECS/100sqm of floor area
Chapter 3
Development Codes
S.No.
Land use
Parking Standards
Remark
District Centre/ Sub-Central Business District/Sub-City Level Commercial areas
3 ECS/100sqm of floor area
- 15.00 sqm for open parking - 28.00 sqm for stilt parking - 32.00 sqm for basement.
Commercial Plot: Retail & Commerce
3 ECS/100sqm of floor area
-
Shopping Malls/Multiplex/Cinema Theatres
3 ECS/100 sqm of floor area
-
Hotels
2.0-3 ECS/100sqm of floor area
- For Population less than 10 lakhs 2 car parking space for every 2 guest room
Service Apartments
2 ECS/100sqm of floor area
Any other commercial centre including Commercial Component along with ISBT/Railway
2 ECS/100sqm of floor area
Wholesale Market
2 ECS/100sqm of floor area
In case of plots up to 300 sqm common parking is to be provided
3
Socio-Cultural Facilities
-
Community Hall
2.0 ECS / 100 sqm of floor area
-
Recreational Club
2 ECS / 100 sqm of floor area
-
Socio-cultural activities such as auditorium, music, dance & drama, centre / meditation, spiritual centre etc.
2 ECS / 100 sqm of floor area
-
Science Centre
2 ECS / 100 sqm of floor area
-
International Convention centre
2 ECS / 100 sqm of floor area
-
Old Age Home/Care Centre for Physically / Mentally challenged/ Working women /men hostel /Adult Education Centre / Orphanage/ Children's Centre / Night Shelter
2 ECS / 100 sqm of floor area
Sport facility for international sports event
2 ECS/100 sqm of floor area.
--
Coaching Center/Training Institute
2 ECS/100 of floor area
--
4
Public-Semi Public
Integrated Office Complex
2 ECS / 100 sq m of floor area
- The norms for Local Government offices / Public Sector Undertakings under Government Land use shall be as per Integrated office complex
District Court
2.0 ECS / 100 sqm of floor area
--
Head Post Office with Administrative
1.0 ECS / 100 sqm. of floor area
--
Office & with / without delivery office
2.0 ECS / 100 sqm of floor area
Amusement Park
2 ECS / 100 sqm. of floor area
--
ISBT/Metro
2 ECS / 100 sqm. of floor area
--
Hospitals
2 ECS / 100 sqm. of floor area
--
Veterinary Hospital
1.00 ECS / 100 sqm. of floor area
--
Veterinary Dispensary
1.00 ECS / 100 sqm. of floor area
--
Nursing and Paramedic institute
2 ECS / 100 sqm. of floor area
--
Medical College
As per norms of Medical Council of India / Regulatory Body
--
5
Industry
Industrial Plot up to 50 sqm area
1.00 ECS
--
Chapter 3
Development Codes
S.No.
Land use
Parking Standards
Remark
Industrial Plot 51sqm -400 sqm area
2 ECS / 100 sqm of floor area
--
Industrial Plot 401 sqm and above
2 ECS / 100 sqm of floor area
--
Flatted group Industry (Min Plot size 400 sqm)
2 ECS / 100 sqm of floor area
--
6
Mixed Land use
Parking @ 2.0 ECS / 100sqm built up area shall be provided within the premises.
Where this is not available, cost of development of parking, shall be payable by the plot allottee /owner to the local body concerned or Multi- level parking to be provided as an option. This condition shall apply even if residential premises are used only for professional activity.