66. Rain Water Harvesting:
a) Water Harvesting: Water harvesting through storing of water runoff including rainwater in all existing and new buildings on plots of 100 square metre and above will be mandatory. The plans submitted shall indicate the system of storm water drainage along with points of collection of rain water in surface reservoirs or in recharge wells.
b) Soft Cover: Provision for soft cover should be included in the plan for building sites:
I. For any building having a minimum covered area of 500 square metre, the applicant should provide soft cover of at least 15% of the plot area.
II. For any other building, having lesser covered area, the soft cover should be at least 10% of the plot area.
67. Recycling of waste water:
All buildings having a covered area of 500 sqm or minimum discharge of 10,000 litre and above per day shall incorporate waste water recycling system. Provisions of facilities and infrastructure to recycle the Wastewater (Grey Water) from bath rooms and kitchen sinks in following manners:
(a) Each building shall have a separate downward pipeline to collect waste water from bath and wash basins and the collected waste water shall be treated adequately by organic or mechanical recycling and taken to a Settling tank for onward pumping to the exclusive overhead tank or to a separate collection unit of overhead tank for exclusive use of toilet flushing through cisterns. The excess waste water not reused for toilet flushing shall be suitably connected to the rain water recharge structures for ground water recharge.
Explanation: For the purposes of this bye-law in so far as the regard to recycling systems are concerned, any other modifications. additional structures, alternative designs furnished by the applicant shall be considered for approval, if it conforms to recycling concept to the satisfaction of the competent authority for building plan approval.
(b) Settling Tanks: The tank should be large enough to hold twice the expected daily flow of wastewater plus 40% to allow sludge accumulation and surge loading. One type of settling tank well-suited for grey water treatment is a septic tank with aeration facility.
(c) Disinfection Facility: Two chemicals viz. Chlorine and Iodine may be used to disinfect water. Organic material in grey water may combine with Chlorine to reduce amount available for disinfection.
(d) Filters: Type of filter required depends on amount of grey water to be filtered and type of contaminates present. Viz., simple drain filter. Activated charcoal, cellulose or ceramic cartridge, slow and or multimedia filters etc could be used based on specific requirement:
(e) Separate Collection Units and Overhead Tank: Grey water for reused to be collected in separate unit and provision is made for a separate overhead tank for storage of recycled grey water for use of toilet flushing and gardening landscaping purposes only:
(f) Dual Pipelines: Laying of dual pipe lines is necessary viz., one for carrying potable water and other for carrying grey water duly marked in orange colour and laid separately for the ease of identifying the pipe carrying grey water.
(g) If separate point to draw water for gardening. landscaping and washing are provided it should be provided with an adequate warning that the water is not fit for drinking.
68. Incentive for rainwater harvesting/Recycling of Waste water:
The incentives in terms of rebate of 10 % on building permission fees will begiven by the Corporation/Council for owners or their successors-in-interest who undertake both recycling of waste water and rain water harvesting structures.
69. Energy Conservation Building:
Building or building complexes having a connected load of 100 KW will be regulated as per the Energy Conservation Code 2007 as amended. Generally, buildings or complexes having airconditioned area of 1,000 sqm or more will also fall under this category.