- (1)
(a) All buildings under this chapter shall conform to the following general requirement in regards to water supply, drainage and sanitation.
(b) All premises intended for human habitations, occupancy or use shall be provided as far as possible with a supply of pure and wholesome water, neither connected with unsafe water supply, nor subject to hazard of back flow
(c) Plumbing fixtures, device and appurtenances if any shall be supplied with water in sufficient volume and at pressure adequate to enable them to function satisfactorily and without undue noise under all normal conditions of use.
(d) Plumbing shall be designed and adjusted to use the minimum quantity of water consistent with proper performance and cleaning.
(e) Devices for heating and storing water if any shall be so designed and installed as to prevent dangers from explosion thought over-heating.
(f) Every building having plumbing fixtures installed and intended for human habitation, occupancy, or use on premises abutting on a public road, alley or easement in which there is a public sewer shall have connection with the sewer.
(g) Each family dwelling unit on premises abutting on a sewer or with a private sewagedisposal system shall have, at least, one water closet and one kitchen type sink.
(h) All other structures for human occupancy or use on premises abutting on a sewer or with a private sewage-disposal system shall have adequate sanitary facilities but in no case less than one water-closet and one other fixture for cleaning purposes.
(2) WATER SUPPLY:
(a) Water supply shall be provided for residential building, office buildi4s, factories, hospitals, Nurses home and medical quarters: hostels, restaurants, cinemas, concert halls, theatres, art Galleries, Libraries, Museums, Bus Stations, Schools, Colleges, and such other buildings as maybe required by the Board for drinking and other necessary uses.
(b) There shall be at least one tap from the piped water supply from drinking purposes for one or two houses.
(3) DRAINAGE AND SANITATION REQUIREMENTS:
(A) There shall be at least One water tap and arrangements for drainage in the vicinity of each water closet or group of water closets in all buildings.
(B) Residences.
(i) Dwellings, with individual conveniences shall have at least the following fitments: -
(a) One bath room provided with a tap.
(b) One water closet; and
(c) One nahanit or sink either in the floor or raised from the floor.
Where only water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.
(C) Buildings other than Residences:
(i) The requirements for fitments for drainage- and sanitation in the ease of buildings other than residences shall be in accordance with Table- I to X as follows: -
Table I Office building
Table II Factories
Table III Cinemas, concert halls and theatres
Table IV Art galleries, libraries and museums
Table V Hospitals; indoor and outdoor patient wards
Table VI Hospitals, administrative buildings, medical staff quarter and nurses' homes
Table VII Hotels
Table Restaurants
Table IX Schools
Table X Hostels
Segregated sanitation for visitors in Public Buildings.
(a) Special requirement of segregated sanitation for Visitors in Public buildings, Government Buildings, Hospitals, Educational Institutions, Commercial buildings etc. Provisions and occupancy shall be referred at Table 54.1 Public toilets are meant for floating population, usually located near railway stations, bus stands, market places, government hospitals, religious centres etc.
(b) The preferable location of these toilets shall be within 200-500 metres from the main entry of the building.
(c) The site shall be earmarked on site plan or a layout plan.
(d) It must be accessible to visitors and general public during the operational hours of the building. However fiscal generation for maintenance may be planned w.r.t. user charges from visitors and general public.
(e) Other factors to be considered:
a. Waste water conveyance/treatment and prevention of contamination. Location on site should allow easy and hygienic emptying of the pits/tanks and ensure that ground water table is not contaminated by waste water percolation.
b. Adequacy in provision.
c. Design consideration.
i. Adequate ventilation
ii. Door Design/ Direction of swing of the door (preferred outwards
iii. Adequate waiting area and
iv. Adequate volumes of water storage.
(f) The facilities should include
i. Separate toilet blocks for men and women with separate entries.
ii. Seats for children to be provided in both sections for men and women.
iii. Waiting and holding area.
iv. Space for facility caretaker and maintenance staff- from where they can monitor and maintain both facilities for men and women.
v. Urinal facilities for men.
vi. Waste water disposal system
vii. Janitor/store room for cleaning material and equipments.
(g) Norms for differently abled within segregated toilets.
i. One special W.C. in a set of toilets shall be provided for the use of differently abled persons with essential provisions of wash basins near the entrance.
ii. Minimum clear opening of the door shall be 900 mm and the door shall swing out.
iii. Suitable arrangement for vertical and horizontal handrails with 50 mm clearance from wall shall be made in the toilet. The W.C. seat shall be 500 mm from the floor.
(h) Water requirement and facilities.
Water requirements to be kept for enough storage for a full day operation either in underground sump or overhead tank.
| No. | Sanitary Unit | For Male Personnel | For Female personnel |
|---|---|---|---|
| 1. | Public toilet near Railway stations (24x7) (a) Water Closet (W.C) (b) Urinals (c) Ablution taps | (a) One for 100 users (b) One unit per 300-500 users (c) One in each W.C | (a) One for 50 users (b) -------- (c) One in each W.C |
| 2. | Public Toilet near market place/offices (for working hours) (a) Water Closet (b) Urinal (c) Ablution Taps | (a) One for 100 users (b) One unit per 200-300 users (c) One in each W.C | (a) One for 50 users (b) --------------- (c) One in each W.C |
| 3. | Public toilets near Public Buildings (a) Water closet (b) Urinals (c) Ablution taps | (a) One for 100 users (b) One unit per 200 - 300 users (c) One in each W.C. | (a) One for 50 users (b) -------------- (c ) One in each W.C |
| No. | Sanitary Unit | Dwelling with individual convenience | Dwelling without individual convenience |
|---|---|---|---|
| 1. | Bath Room | One provided with water tap | One for every two tenements |
| 2. | Water Closet | One | One for every two tenements |
| 3. | Sink | One | |
| 4. | Water Tap | One with drainage Arrangement in each tenement One in common bath room and common water closet. |