51. High Rise
Buildings higher than 15 m of height without stilts and above 17.5 m of height with stilts shall be considered as high-rise buildings.
52. Plot area
Plots to be used for high rise development in an approved layout Plan, Comprehensive plan or sub division as prepared and approved by competent authority.
53. Means of Access
(a) A building shall be on a street or upon spaces directly connected from the street by a hard surface approach road; width of approach road is not less than 9 metres.
(b) If there is any bend or curve on the approach road a sufficient width shall be provided at the curve to enable the fire appliances to turn, the turning circle being at least of 9.0 m radius.
The approach road to the building and open spaces on all its sides up to 6 m width and layout for the same shall be done with consultation with the Chief fire officer. The said open space shall be kept free from any obstruction and shall be motor able.
(d) Main entrance to the premises shall be adequate width to allow easy access to the fire engine and in no case, it shall measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises. If archway is provided, the height of the archway shall not be less than 5 m.
(e) For multi-storeyed group housing schemes on one plot, the width of approach road to the site shall be of minimum 18m width.
- FAR, SETBACKS AND HEIGHTS OF RESIDENTIAL BUILDINGS
| Proposed setbacks and heights of residential buildings | ||||||||
| No | Plot Area (sq.mt.) | FAR | Maximum Height (in metres) | Setbacks proposed (in meters) | ||||
| Front | Rear | Side 1 | Side 2 | |||||
| 1 | 50 - 90 | 150 | 7 | G+1 | 1.50 | 0.90 | 0.60 | 0.60 |
| 2 | 91 - 150 | 180 | 11 | G+2 | 1.50 | 0.90 | 0.90 | 0.90 |
| 3 | 151 - 300 | 180 | 11 | G+2 | 2.00 | 1.20 | 1.20 | 1.20 |
| 4 | 301 - 500 | 180 | 13 | G+3 | 3.00 | 2.00 | 1.80 | 1.20 |
| 5 | 501 - 750 | 200 | 13 | G+3 | 4.00 | 3.00 | 2.40 | 1.20 |
| 6 | 751 -1000 | 200 | 16 | G+4 | 5.00 | 4.50 | 4.20 | 2.50 |
| Above 16 MTS | ||||||||
| 7 | 1001-1500 | 250 | 19 | G+5 | 6.00 | 4.50 | 4.50 | 3.00 |
| 8 | 1501 -2000 | 250 | 22 | G+6 | 7.00 | 4.50 | 4.50 | 3.50 |
| 9 | 2001 -2500 | 250 | 25 | G+7 | 8.00 | 4.50 | 4.50 | 4.00 |
Parking spaces.
(a) The parking space shall be provided as per the provisions of the Master Plan or Zonal Plan.
(b) In case of High-Rise building parking will be permitted at any or all of the following (1) Basement
(2) Stilts
(3) Podium.
(c) Stacked /Multilevel/Automated parking is also permitted.