Every person who erects a building shall provide a means of access to such building a clear way, not less than 3.6 m. (or 12 ft.) in which upto 3 storeys and 5 m (or 16 ft.) in width beyond three storeys from a street to the entrance door of such building, such pathway to be, so long as it is used as a means of access to that building maintained free from any obstruction and shall not at any time cause or permit any portion of any building below a height of 5 m. (16 ft.) to overhang or project over or into such passage.
-
No building shall be erected so as to deprive any other building of the means of access as provided in this chapter.
-
Every person who erects a building shall indicate upon any plan, required to be furnished by him in accordance with these byelaws, the whole area of such means of access by a distinguishing colour and description.
-
Every person who erects a building shall not at any time erect or cause or permit to be erected or re-erected any building which in any way encroaches upon or diminished the area so set apart for this purpose.
-
The space so set apart shall be separately distinguished from any house gully or open space required to be provided under any other byelaw enforced by the Corporation/Council.
-
Every such means of access shall be drained and lighted to the satisfaction of the Corporation/Council and manhole covers and other drainages, water or any other fittings laid in such means of access shall be flush with the finished surface level so as not to obstruct the safe travel over the same.
-
A person who under takes construction work on building shall not reduce the access to any building previously existing below the minimum width as required under Byelaw 31.
-
The means of access under these byelaws shall not be deemed to be suitable and sufficient until they have been approved by Corporation/Council who shall have power to prescribe the width of the clear way which he shall communicate.
-
Access to Dwelling Units and Rooms: - In every building containing more than one dwelling, access shall be provided to each dwelling unit without the necessity of passage through any other dwelling unit
39. Open Space Requirements: -
Open Air Space: - Every room intended for human habitation shall abut on an interior or exterior open-air space or on an open verandah opening on to such interior or exterior toilet open space.
-
Joint Open Air Space: - Every such interior or exterior open-air space unless the latter is a street, shall be maintained for the benefit of such building exclusively and shall be entirely within the owner's own premises.
-
If such interior or exterior open-air space is intended to be used for the benefit or more than one building belonging to the same owner, then the width of such open-air space shall be equal to one-half of the height of the tallest building on such open-air space.
-
Open Space to be open to Sky. Every open space, whether exterior or interior, provided in pursuance of any regulation or byelaw or under an agreement lodged with the Corporation/Council shall be kept free from any erection thereon shall be open to the sky. Every open space or, chowk provided under these byelaws shall have a suitable and sufficient access. No open drain, except for rain water, shall be constructed in any open space required by these byelaws
-
Safeguard against Reduction of Open Space: - No construction work on a building shall be allowed if such work operation to reduce an open-air space of any other adjoining building belonging to the same owner to an extent less than what is prescribed by any of the byelaws in force at the time of the proposed work or reduce further such open space if it is already less than that prescribed.
-
Bazar Area: - In new Bazar area and continuous shops provision shall be made for an arcade of 1.8 m. (or 6 ft.) width to be built by the allottee as public passage.
-
Additions or Extension to a Building:- No addition or extension to a building shall be allowed unless the addition or extension is such as would be permissible if the whole building was reconstructed from the Plinth with the open space required under these bye-laws applicable to the site of the building at the time of proposed addition, and no addition or extension to a building shall be allowed which would diminish the extent of air space below the minimum requirement under these bye-laws.
-
Building line:- The front of every building shall be in the same line as far as possible and the Corporation/Council shall. see that the building or buildings are constructed in the same line after giving the provision for setback mentioned in Bye-law 54, 58 & 59