| Item | As Per Building Plan | Remark byauthorizedrepresentative | ||||
| Yes | No | Nonapplicable | Applicable | |||
| 1) Structural Safety | ||||||
| 1. Provide Design Basis Report as per the document | ||||||
| 2. Provide description of Sub-structure and Super-structure as per the format given in the Ref(5&6) enclosed. | ||||||
| 3. Provide brief Description of Structural System with sketches, images of drawing, etc. with specific focus on Lateral load resisting system*. | ||||||
| 4. Provide brief note on modeling, software used etc.Clear mention whether infill / partition wall is idealized as part of lateral load system? | ||||||
| 5. Provide the height of building in meters. | ||||||
| 6. Provide plan dimensions of the building (mt x mt) | ||||||
| EQ Loading Details | ||||||
| 7. Provide following EQ loading details. | ||||||
| a) Zone Factor | ||||||
| b) Importance factor | ||||||
| c) Response Reduction factor | ||||||
| d) Soil Type | ||||||
| e) % LL considered in seismic | ||||||
| f) Time Period in the horizontal X- direction (sec) | ||||||
| g) Time Period in the horizontal Z-direction (sec) | ||||||
| h) Total Seismic weight (Sw) of building (kN) | ||||||
| i) Static Base-shear in X-direction (as % of Sw) | ||||||
| j) Static Base-shear in Z-direction (as % of Sw) | ||||||
| k) Table of distribution for static base shear | ||||||
| l) Max. deflection at roof level. (mm) | ||||||
| m) Max. inter storey drift./ Height | ||||||
| Vertical Elements Details | ||||||
| 8. Provide following data regarding Vertical Elements. | ||||||
| a) Size of maximum loaded column | ||||||
| b) Gravity load on max. loaded column | ||||||
| c) Axial stress in max. loaded column (Gravity loads) | ||||||
| d) Grade of max. loaded column | ||||||
| e) Axial settlement in max. loaded column | ||||||
| f) Axial settlement in min. loaded column | ||||||
| g) % Base-shear resisted by all columns along X (static) | ||||||
| h) % Base-shear resisted by all columns along Z (static) | ||||||
| Dynamic Analysis | ||||||
| 9. Provide following data from Dynamic Analysis | ||||||
| a) Total gravity load on floating column (provide table if there are multiple floating | ||||||
mm°
(1)/(2)
| columns) | ||||||||||
| b) Size and span of girders supporting floating columns | ||||||||||
| c) Number of floors supported by floating columns | ||||||||||
| d) Deflection of girder under column (from model) | ||||||||||
| e) Deflection of girder under column (from s/s action) | ||||||||||
| f) Specific details about floating columns on cantilevergirders (Refer Table below) | ||||||||||
| 10. Provide, if applicable, following data for eachcantilever. | ||||||||||
| a) Cantilever span | ||||||||||
| b) Structural system | ||||||||||
| c) Nature of usage | ||||||||||
| d) Maximum elastic deflection under gravity loads | ||||||||||
| 11. Provide stability calculations for uplift and overturning(model extract in case of model) | ||||||||||
| 12. Typical design calculations for footings | ||||||||||
| 13. Typical design calculations for RCC columns Composite Columns | ||||||||||
| 14. Typical design calculations for RCC walls | ||||||||||
| 15. Typical design calculations for RC beams (Or Steel Beams) | ||||||||||
| 16. Typical design calculations for RCC Girders (Or Steel Girders/Truss) | ||||||||||
| 17. Typical design calculations for Steel Bracings | ||||||||||
| 18. Provide a note on special provisions suggested for the building (like dampers etc.) | ||||||||||
| 19. Soft copy of model including input and output. | ||||||||||
| Provide following data from Dynamic Analysis | ||||||||||
| Modes | Frequency | Time Period in Sec | ||||||||
| Provide Corner displacements (mm) for Torsional Irregularity(along x-direction) in the following format. | ||||||||||||
| Load Case | Corner-1 | Corner-2 | Corner-2 | Corner-4 | Avg-x | %Max./Avg. | ||||||
| Eq-x | ||||||||||||
| Wl-x | ||||||||||||
| Provide Corner displacements (mm) for Torsional Irregularity(along z-direction) in the following format. | ||||||||||||
| Load Case | Corner-1 | Corner-2 | Corner-2 | Corner-4 | Avg-x | %Max./Avg. | ||||||
| Eq-z | ||||||||||||
| Wl-z | ||||||||||||
| Provide acceleration (mg) values in the following format. | ||||||||||||
| Eq-x | Eq-z | WL-x | WL-z | |||||||||
| Ref 5 | ||||||||||||
| DESCRIPTION OF SUB-STRUCTURE | ||||||||||||
| No. of basement | ||||||||||||
| Minimum clearance between outermost basement retaining wall and compound wall | ||||||||||||
| Has a Shoring system been installed? Submit sectional detail of the shoring system | ||||||||||||
| Give details of methodology used to resist uplift pressure due to ground water for tower portion as well as the portion outside the tower. | ||||||||||||
| Description of the foundation for the tower block | ||||||||||||
| Nature of Foundation | ||||||||||||
| SBC assumed T/sq.mt. | ||||||||||||
| Sub-grade Elastic Modulus | ||||||||||||
| Intended Use of basements | ||||||||||||
| If rock anchors are used, are they grouted after installation and stressing? | ||||||||||||
a.mm²
U BU A = U BU A
| Ratio of plan dimension | |
|---|---|
| Typical Floor to floor height in m Maximum floor to floor height in entire height of building in m. | |
| Aspect ratio ( Height of Building till Terrace / Minimum Dimension of Building) | |
| Type of floor slab | |
| Average thickness of floor slab in mm | |
| Whether column are RCC, Composite or In structural steel |
n = m