- Installation of Solar Assisted Water Heating System in Buildings: to ensure the implementation of the guidelines issued by ministry of non-conventional energy sources on accelerated development and deployment of solar water heating systems in domestic, industrial and commercial sectors. No new building in the following categories in which there is a system of installation for supplying hot water shall be built unless the system of the installation is also having an auxiliary solar assisted water heating system:-
i) Hospitals and Nursing Home Hotels, Lodges, and Guest Houses, Group Housing with the plot area of 4000 sq m.
iii) Hostels of Schools, Colleges and Training Centres with more than 100 Students.
iv) Barracks of armed forces, paramilitary forces and police
v) Individual residential buildings having more than 150 sq m. plinth area
vi) Functional Buildings of Railway Stations and Air Ports like waiting rooms, retiring rooms, rest rooms, inspection bungalows and catering units
vii) Community Centres, Banquet Halls, Barat Ghars, Kalayana Mandaps and buildings for similar use.
A. Definitions
| (i) | “Solar Assisted Water Heating System | A device to heat water using solar energy as heat source. |
|---|---|---|
| (ii) | “Auxiliary back up” | Electricity operated or fuel fired boilers/ systems to heat water coming out from solar water heating system to meet continuous requirement of hot |
### 1###
| water. | ||
|---|---|---|
| (iii) | “New Building” | Such buildings of above said categories for which construction plans have been submitted to the Authority for clearance. |
| (iv) | “Existing building” | Such buildings, which are licensed to perform their respective business. |
B. Guidelines for Installation of Solar Water Heating System
i. New Buildings: Clearance of plan for the construction of new buildings of the aforesaid categories shall only be given if they have a provision in the building design itself for an insulated pipeline from the rooftop in the building to various distribution points where hot water is required. The building must have a provision for continuous water supply to the solar water heating system. The building should also have open space on the rooftop, which receives direct sun light. The load bearing capacity of the roof should at least be 50 kg. per sqm. All new buildings of above said categories must complete installation of solar water heating systems before obtaining necessary license to commence their business.
ii. Existing Buildings: Installation of Solar Assisted Water Heating Systems in the existing building shall be made mandatory at the time of change of use to above said category provided there is a system or installation for supplying hot water.
iii. Capacity: The capacity of solar water heating system to be installed on the building of different categories shall be decided in consultation with the local body. The recommended minimum capacity shall not be less than 25 lt. per day for each bathroom and kitchen subject to
ommo
SΔ APQ = SΔ AQP + SΔ PQQ
the condition that maximum of 50% of the total roof area is provided with the system.
iv. Specifications: Installation of Solar Assisted Water Heating System shall conform to BIS specification IS 12933. The solar collectors used in the system shall have the BIS certification mark.
v. Auxiliary System: Wherever hot water requirement is continuous, auxiliary heating arrangement either with electric elements or oil or adequate capacity may be provided.
- A separate guide lines shall be issued for installation of solar plant, solar power backup and metering system by the Urban Development and Housing Department.
Annexure-III Maximum Permissible FAR for Different ULBs
| Sl. | Name of ULB | Maximum Permissible FAR | |
| Residential | Commercial | ||
| 1 | Ranchi Municipal Corporation | As per Master Plan | |
| 2 | Dhanbad Municipal Corporation & MADA Area | 2.5 | 2.5 |
| 3 | Chirkunda Nagar Panchayat | 2.0 | 2.0 |
| 4 | Giridih Nagar Parishad | 2.5 | 2.5 |
| 5 | Hazaribagh Nagar Parishad | 2.5 | 2.5 |
| 6 | Jhumritilya Nagar Parishad | 2.0 | 2.0 |
| 7 | Koderma Nagar Panchayat | 2.0 | 2.0 |
| 8 | Chas Municipal Corporation | 2.5 | 2.5 |
| 9 | Phusaro Nagar Parishad | 2.0 | 2.0 |
| 10 | Chatra Nagar Parishad | 2.0 | 2.0 |
| 11 | Bundu Nagar Panchayat | 2.0 | 2.0 |
| 12 | Gumla Nahgar Panchayat | 2.0 | 2.0 |
| 13 | Lohardaga Nagar Parishad | 2.0 | 2.0 |
| 14 | Simdega Nagar Parishad | 2.0 | 2.0 |
| 15 | Khunti Nagar Panchayat | 2.0 | 2.0 |
| 16 | Ramgarh Nagar Parishad | 2.0 | 2.5 |
| 17 | Dumka Nagar Parishad | 2.5 | 2.5 |
| 18 | Basukinath Nagar Panchayat | 2.0 | 2.0 |
| 19 | Deoghar Municipal Corporation | 2.5 | 2.5 |
| 20 | Madhupur Nagar Parishad | 2.0 | 2.0 |
| 21 | Godda Nagar Panchayat | 2.0 | 2.0 |
| 22 | Pakur Nagar Panchayat | 2.0 | 2.0 |
| 23 | Sahebganj Nagar Parishad | 2.0 | 2.0 |
| 24 | Rajmahal Nagar Panchayat | 2.0 | 2.0 |
| 25 | Mihijham Nagar Parishad | 2.0 | 2.0 |
| 26 | Jamtara Nagar Panchayat | 2.0 | 2.0 |
| 27 | Chaibasa Nagar Parishad | ||
nimo
usm of
[Signature]
| 38 | Garhwa Nagar Panchayat | 2.0 | 2.0 |
| 39 | Nagar Untari Nagar Panchayat | 1.5 | 1.5 |
| 40 | Manjhiaon Nagar Panchayat | 1.5 | 1.5 |
| 41 | Latehar Nagar Panchayat | 1.5 | 2.0 |
| 42 | Ranchi Regional Development Authority,Ranchi | As per Master Plan | |
Note:- (1) For other occupancy the FAR value shall be as per these Bye-laws.
(2) The FAR value may be altered/modified according to the respective up coming Master Plan of Towns. The Urban Development & Housing Department can altered/modified FAR value as and when required.
ommo
Lusor m/.
[Signature]
Annexure-IV
Form For Mobile Tower Permission
| 1 | Name of the Firm | - | Photo | |
| 2 | Registration of the Firm | - | ||
| 3 | Details of land on which tower is to be installed (land related paper):(a) Photocopy of sale deed/lease(b) Photocopy of Khatiyan(c) Photocopy of Mutation(d) Photocopy of Rent receipt | |||
| 4 | Land/Building Owner of Consent Paper/ Agreement | - | ||
| 5 | Certificate satisfy that proposed tower shall be able to carry wind pressure. | - | ||
| 6 | Proposed tower is not in a air traffic zone a certificate from Airport Authority has been attached for the same. | - | ||
| 7 | A certificate that the concern building is capable of carrying load of the proposed tower. | - | ||
| 8 | Photocopy of structural design of propose tower. | - | ||
| 9 | Height of the proposed tower shall be measured form ground floor of the building on which tower is going to be installed. | - | m. | |
| 10 | (a) If height is less than 40m. and outside 7km. than whether online application has been made or not. A oath with detailing out that in case of any objection/rejection correction measures shall be taken out by TSPs/IPs.OR | - | ||
| (b) If height is above 40m. and under 7km. then a certificate of SACFA/Airport Authority of India is available or not. | ||||
| 11 | Acknowledgement receipt has been enclosed or not by TSPs/IPs in context of self certificate produced before TERM CELL of DOT with regard to EMR.OR | - | ||
simms like ∞/
xm
| Affidavit enclosed or not by TSPs/IPs in context of self certificate produced before TERM CELL of DOT with regard to EMR. | |||
|---|---|---|---|
| 12 | Fee as per Jharkhand Communication Tower and Related Structures Policy, 2015 for 8m. height/more than 8m. height (Non refundable). | - | Bank Draft No.----Name of Bank ----Date ---- |
you're
m2