30. Restriction on permission
Without prejudice to any other stipulation in these bye laws, no permission to construct a building on a site shall be granted:
30.1 In areas of natural waterways or drains, as detailed in the Development Plan, and drainage plan as modified from time to time;
30.2 If the use to which the site is proposed to be put does not conform to the use earmarked in the Development Plan/Master Plan/Zonal Development Plan;
30.3 If the building is to be constructed over or under a municipal drain, sewerage line, electrical line, water main, any other government or public land, or public utility services;
30.4 As Jharkhand is located in Seismic Zone II, III and IV if the Structural Plans are not prepared taking this into account.
30.5 In case of areas which get flooded, the Structural Plans are not prepared taking this into account.
31. Requirement of Site
31.1 No building shall be constructed on any site on any part of which there is deposited refuse, excreta or other offensive matter objectionable to the Authority. Until such refuse has been removed there from and the site has been prepared or left in a manner suitable for building purposes to the satisfaction of the Authority;
31.2 Wherever the dampness of a site or the nature of the soil renders such precautions necessary, the ground surface of the site between the walls of any building erected thereon shall be rendered damp-proof to the satisfaction of the Authority;
31.3 Any land, passage or other area within the cartilage of a building shall, if the Authority so requires, be effectively drained by surface water drains or other means;
31.4 If the foundation of the external wall along a Street is located at a distance less than one meters from the edge of the street or road margin including the drain;
The written approval of the Authority shall be obtained for connecting any sub-soil or surface water drain to a sewer;
omni: kgor 37.
[Signature]
32. Distance from Electric lines
No verandah, balcony or the like shall be allowed to be erected or re-erected or any additions or alterations made to a building, within the distances ‘quoted below between the building and any overhead electric supply line.
The minimum distance from the electric line shall be as per Table 5.
Table - 5: Minimum distance from electric line
| Vertical distance in meters | Horizontal distance in meters | |
|---|---|---|
| Low and medium voltage lines and service lines | 2.5 | 2.5 |
| High voltage lines up to and including 11,000 Volt | Not Permitted | 3.7 |
| High voltage lines above 11,000 volt and up to and including 33,000 Volt | Not Permitted | 3.7 |
| Extra high voltage line beyond 33,000 Volt | Not Permitted | 3.7 (Plus 0.3 meters for every additional 33,000 volts or part thereof) |
33. Plantation
33.1 In every building area, at least 5% of the land shall be covered by plantation (tree cover), but in case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover). Internal gardens within the building shall be encouraged.
34. Means of Access
34.1 Every plot shall abut on a public/private means of access like streets/roads of duly formed of width as specified in these byelaws or specified in the Master Plan/Development/Zonal Plan/Scheme.
The minimum width of the road/street required for access to a new building in an existing colony not developed by any authorized agency such as Regional Development Authority, Municipality, Housing Board, Co-operative societies, Government and Semi government organization shall be as per Table 6.
| Old Area | ||
| Sl. No. | Maximum Length of the road in Meter | Minimum width of road of street in Meter |
| (i) | (ii) | (iii) |
| 1 | Upto 50 meter | 3.6 meter |
| 2 | Exceeding 50 meter and upto 100 meter | 5.1 meter |
| 3 | Exceeding 100 up to 300 meter | 6.6 meter |
| 4 | Exceeding 300 meter | 7.5 meter |
| Note-On less than 6.1 m. wide roads the encroachment from both sides will be removed by measuring 3.05 m. from the centre line of the width of roads declared by or belonging to Road Construction Department Jharkhand, Municipal Authorities, Housing Board, Co-operative Societies, Government and Semi-Government Organizations In other cases | ||
[Illegible Handwriting]
| maximum 3.05 m. land from such revenue plot on either side will be taken into account to make it 6.1 m. wide road and the construction falling in between the said width of road will be removed as an encroachment.Similarly 1.80 m. and 2.55 m. land from each Revenue plot on either side will be taken into account to make it 3.1 m. and 5.1 m. wide road correspondingly | ||
| New Area (Residential) | ||
| Sl. No. | Maximum Length of the road in Meter | Minimum width of road of street in Meter |
| 1 | Up to 100 | 6.10 |
| 2 | More than 100 to 250 | 7.5 |
| 2 | More than 250 to 500 | 9.10 |
| 3 | More than 500 to 1000 | 12.20 |
| 4 | More than 1000 | 15.30 |
35. Minimum size of plots and road width
35.1 The minimum size of plots and road width for different categories of building is given in Table 7.
Table - 7: Category wise size of plots
| Category | Min. road width (m) | Min. size of plot in Sqm. |
|---|---|---|
| Marriage Halls | 12.20 | 1000 |
| Cinema, Multiplex, Shopping Malls, Convention centers, Game centers, | 18.30 | 2000 |
| Social clubs and amenities | 12.20 | 1000 |
| Multi storey car parking | 12.20 | 1000 |
| Office buildings | 12.20 | 300 |
| Primary/Upper Primary school | 09.00 | 2000 |
| High School, Residential School | 12.20 | 6000 |
| +2 College / Junior College | 12.20 | 4000 |
| Degree College | 12.20 | 6000 |
| Technical educational institution | 12.20 | 10000 |
| Petrol Pumps/Filling stations | 12.20 | 500 |
| Restaurant | 12.20 | 500 |
| LPG storages | 12.20 | 500 |
| Places of congregation | 12.20 | 500 |
| Public libraries | 12.20 | 300 |
| Conference hall | 12.20 | 1000 |
| Community hall | 12.20 | 500 |
| Nursing homes/polyclinics/Hospital | 12.20 | 300 |
| Hotel (below three star) | 12.20 | 1000 |
| Hotel (three star and above) | 18.30 | 2000 |
| R&D Lab | 18.30 | 1500 |
| Group Housing | 6.10 | 3000 |
ormno here of √
Note:
(1) In exceptional cases the Authority may consider revising the minimum size of plot with the approval of the Government.
(2) The above (requirement) area of minimum size of the plot may be relaxed by 5% while sanctioning the plan.
(3) No high rise building (building with a height above 16.4 meters) shall be allowed on a plot size less than 1000 sqm.
(4) Minimum existing road width for building more than 13.3 m in height shall be not less than 6.1 m.
(5) For all plots abutting a road less than 12.2m width for proposed to be used for Primary/Upper Primary School a lay-by of paved area contiguous to the road for turning of vehicles and fire engines should be left. This lay-by should be of minimum dimension of 9m x 9m.
36. Minimum setbacks & Height for non-high rise buildings
(1) The minimum setbacks and height of buildings permissible in a given size/plot for residential in non high rising category shall be as per Table 8 and 9. The minimum setback for commercial and mercantile buildings shall be as per Table 10 and 11.
Table - 8: Minimum Front and Rear setbacks and height of residential buildings
| Sl. | Average Depth of plot (In meters) | Building Height Upto G+2 Maximum-10m | Building Height Upto G+3 Maximum-13.3m | Building Height Upto G+4 Maximum-16.4m | |||
| Minimum Front set back (m) | Minimum Rear set back (m) | Minimum Front set back (m) | Minimum Rear set back (m) | Minimum Front set back (m) | Minimum Rear set back (m) | ||
| (i) | (ii) | (iii) | (iv) | (v) | (vi) | (vii) | (viii) |
| 1 | Upto 10m | 1.5 | 0.90 | No construction shall be permitted | No construction shall be permitted | ||
| 2 | Exceeding 10m & upto 15m | 2.0 | 1.5 | 3.0 | 1.5 | No construction shall be permitted | |
| 3 | Exceeding 15m & upto 21m | 2.5 | 1.5 | 3.0 | 1.8 | 3.0 | 3.0 |
| 4 | Exceeding 21m & upto 27m | 3.0 | 1.8 | 3.0 | 2.0 | 3.5 | 3.0 |
| 5 | Exceeding 27m & upto 33m | 4.0 | 2.5 | 4.0 | 3.0 | 4.0 | 3.5 |
| 6 | Exceeding 33m & upto 39m | 4.0 | 3.0 | 4.5 | 4.0 | 4.5 | 4.0 |
| 7 | Exceeding 39m & upto 45m | 4.0 | 4.0 | 4.5 | 4.0 | 5.0 | 4.5 |
| 8 | More the 45m | 4.0 | 4.0 | 5.0 | 5.0 | 6.0 | 5.0 |
anno
SΔ APQ = SΔ AQP + SΔ PQR
X
37. Minimum setbacks for high rise buildings
(1) For high-rise/ multi-storied buildings, the open spaces around the building unless or otherwise specified shall be as given in the Table 14.
| SI. | Height of the Building Upto (m) | Exterior open spaces to be left out on all sides in m. | |
| Front setback | Side and Rear setback | ||
| 1 | More than 16.4 and upto 19.25m | 6.5 | 4.5 |
| 2 | More than 19.25m and upto 23.10m | 7.5 | 4.5 |
| 3 | More than 23.10m and upto 30m | 8.0 | 5.0 |
| 4 | In case of buildings of more than 30m height, for every increase in height of 3.35m. or fraction thereof or addition of one floor, 1m. in the front set back and 0.75 m. in the sides and rear setbacks shall be added. | ||
Note:-
(1) In no case the minimum setbacks shall be less than those specified in sub-section 42.1 of these Bye Law for high rise buildings in the mentioned category.
(3) In case of multi storied buildings the exterior open space around a building shall be of hard surface capable of taking load of fire, engine weighting up to 45 tones.