49.1 For Residential
49.1.1 For no. of flats more than 8 and up to 18, one lift of the capacity of 6 passengers will be mandatory for G+4 and above.


49.1.2 For every 16 flats and part thereof one lift of the capacity of 6 passengers shall be provided for residential buildings up to G+4 or of the height of 12 meters and above.
49.1.3 However in case, where part thereof is less than 50%, then the requirement can be met by increasing the passenger capacity of lift.
49.1.4 If the number of flats in a multistoried residential building is more than 12, the provision of lift will be compulsory for G+3, even if the height of the building is less than 12 meters. The capacity and no. of lifts shall be as mentioned above.
49.1.5 Provision of lift should be made for residential buildings of more than G+3 storied or buildings having the height of 12 meters, whichever is lower
49.1.6 Provision of one stretcher lift every building more than 6 storey height
49.1.7 Every lift should have Provision of automatic rescue device, door sensor and automatic fire proof door.
49.2 For Non-Residential:
49.2.1 Building above ground + 2 floor
49.2.2 1 person capacity per 500 sqm. or fraction thereof of built-up area excluding ground floor and covered parking area
49.2.3 Minimum number of lifts to be 2 for all non-residential building above ground + 3 and the minimum capacity shall be 6 persons per floor.
Note:
-
All the lift requirements shall be subject to fire requirement.
-
All sizes of lift (i.e. car inside, lift well, entrance, headroom etc.) shall be as per the requirements of N.B.C. or as per manufacturers specifications.
-
All lifts shall be inspected at least once a year by the agency designated by the Authority. The Authority can also outsource the inspection of lifts.
-
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation.
50. Barrier free access for the differently abled person
50.1 Barrier free environment is one, which enables people with disabilities to move about safely and freely and to use all facilities within the built environment. The goal of barrier free design is to provide an environment that supports the independent functioning of individuals so that they can get into and participate in all activities without assistance.

SΔ APQ = SΔ AQP + SΔ PQQ
50.2 The main purpose is to integrate disabled and elderly persons fully into the society. In view of the above, the Government of India has enacted the Disabilities Act, 1955.
50.3 Section 44, 45 and 46 of the said Act stipulates that the appropriate Governments, local authorities to ensure provisions of barrier free facilities in all new Government buildings and public utilities roads and transport. Also, in 1996 Government of India enacted another person with Disabilities (Equal Opportunity, Protection of Rights and Full Participation) Act for the Barrier Free Environment for differently abled persons.
50.4 Site Development:- Level of the roads, access paths and parking areas shall be described in the plan along with specification of the materials.
50.5 Access Path/Walk Way :- Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm. wide having even surface without any steps. Slope, if any, shall not have gradient greater than 5%. Selection of floor materials shall be made suitably to attract or to guide visually impaired persons (Limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emit different sound to guide visually impaired persons hereinafter referred to as “guiding floor material”). Finishes shall have non slip surface with a texture traversable by a wheel chair. Curbs wherever provided should blend to a common level.
50.6 Parking:- For parking of vehicles of handicapped people the following provisions shall be made:
50.6.1 Surface parking for two car spaces shall be provided near entrance for the physically handicapped persons with maximum travel distance of 30 meter from building entrance.
50.6.2 The width of parking bay shall be minimum 3.6 meter.
50.6.3 The information stating that the space is reserved for handicapped persons shall be conspicuously displayed.
50.6.4 Guiding floor materials shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided.
50.7 Building requirements:- The specified facilities for the buildings for handicapped persons shall be as follows:
Lightening Protection
53.1 To arrest Lightening, provision of lightening conductor is mandatory in the all types of buildings as per NBC-2005 norms.
54. Penal Action against Builders/Technical Personnel
54.1 Not withstanding anything contained in these regulations, the Authority reserves the right to debar / black list the builder/technical person who have deviated from the professional conduct or has made any fraudulent statement or has misrepresented/suppressed any material facts in his application/plan or is involved in construction of the building deviating from the approved plan/norms of these bye laws.
54.2 Before taking any action under clause specified above, the Authority shall issue a notice specifying the reasons thereof asking for a show-cause within 15 days as to why such builder/technical person shall not be debarred/blacklisted. After receipt of the show cause, if any, the same shall be placed before the Authority for a decision on debarring/black listing the technical person/ builder. The decision of the Authority in this regard shall be published in the Notice Board of the Authority and the Govt. website.
54.3 An appeal against an order under sub-clause above shall lie under sections of the Municipal Act/other relevant Act.
55. Builder to register an association
55.1 The builder shall cause to register an Association of apartment owners as required under The Jharkhand Apartment Ownership Act, 2006 before occupancy certificate for minimum of 50% or more of the floor area is given.
55.2 The builder shall enter into agreement with the apartment owners' Association/Society at the time of handing over of the apartment/premises. This agreement shall contain the terms of maintenance of common amenities which will include all the conveyances contained in the deed of sale to the owners of the flats. The maintenance period will be minimum of one year from the date of such agreement. The copy of the agreement shall be submitted to the authorities also before getting the occupancy certificate.
56. Reference to the standards
The following standards shall be referred while preparing the design of the building:
56.1 The standards relating to water and sanitation requirements for various occupancies and uses, shall be referred to as per section 1 of part-9 of NBC of India, 2005 group-5.