58. For construction of Multi-storied building
58.1 Construction of multi-storied building shall not be permitted villages/ wards/municipalities/planning areas specified by the State Government. The Authority may include or exclude any other areas for prohibition of multi storied building from time to time.
58.2 The Authority may restrict construction of multistoried buildings in any other area on the basis of objective assessment of the available infrastructure and planning needs after obtaining due approval of the Government.
58.3 Before commencement of these bye laws, where permission has been granted conditionally, such cases shall be dealt with under corresponding provisions of these Bye laws without any major change, or removal of construction, subject to the condition where violation of Heritage Zone conditions has occurred, this relaxation shall not apply.
58.4 No Condonation in parking requirements, fire fighting provisions, health and structural safety requirements in case of development of Multi Storied buildings shall be allowed.
58.5 In addition to the provisions of Part 4 Fire and Life Safety of National Building Code of India 2005 (Group 1), the Planning Authority may insist on suitable provisions in building from fire safety and fire fighting point of view depending on the occupancy and height of buildings in the case of Multi Storied building.
58.6 The following shall be mandatory for the development of all Commercial and multi dwelling units including apartments:
58.6.1 Land left for road widening/cul-de-sac should be paved and in matching level of the existing road.
58.6.2 All drainage inside the plot should be covered and underground.
58.6.3 All service pipes, PVC water tanks etc. should be concealed from all side.
58.6.4 Lighting poles with lights within the boundary wall facing towards the road. One lighting poles with minimum height of 6mtr. at every 15mtr. or fraction thereof of the length of the front boundary wall shall be provided with 150W of LED, facing towards the road for street lighting and should also be connected to the Generator.
Lisor on
XM
58.6.5 Plantation–Number and type of plantation with the boundary along the road.
One tree of suitable variety should be planted at every 6m. or fraction thereof of the length of the front boundary.
58.6.6 Water harvesting system for recharge well shall be provided as per NBC norms.
58.6.7 Solid waste disposal bins of suitable size inside the plot.
58.6.8 Lifts, pumps, external lighting shall be connected to pollution free noiseless Generator.
58.6.9 Minimum of 3 amp./flat to be provided from pollution free noiseless Generator
58.6.10 Lift shall be mandatory for above G+3 or as provided in this bye-laws and should be connected to power backup generator.
58.6.11 All electrical power generators shall be noiseless & pollution free.
58.6.12 Recycling of waste water shall be made mandatory for any building consuming more than 12000 liters per day or having 24 flats or more, whichever is lower.
58.6.13 Service Ducts shall not be counted in the F.A.R. of building.
58.6.14 No FAR should be added for parking for any floor except the lockup, garage.
58.6.15 Minimum 50% of all paving around the building the driveway etc. should be soft paving in the form of interlocking, concrete block (without mortar or solid sub base) or such other systems to insure surface water percolation into the subsoil.
58.6.16 Minimum 50% of bricks use in the building should be made of fly-ash
58.6.18 If more than one storey height is covered with fiber glass or like materials which permits light, it should not be counted for covered area and FAR calculations. If covered with unusable/non accessible RCC roof, the covered atrium area will be counted for covered area calculation but not for FAR value. This is done to encourage better standard of planning for bigger shopping malls.
Atriums open to sky or covered with the light weight roof member which permits light shall also not be
onmo year of
58.6.19
used for F.A.R calculations unless the roof top is used as a usable floor space.
For ventilation of the spaces for water closets and bath rooms, if not opening on to front, rear, side or interior open space these shall open on to the ventilation shaft, the size of which shall not be less than as given in Table below. This shall be limited for natural ventilation only".
58.6.20 Ventilation requirements can be met by the mechanical ventilation system like air conditioning etc. Toilets may be permitted without any exterior openings for the buildings like hotels, commercial complexes etc as per N.B.C, but not for apartments and residences.
| Sl. | Height of Building | Area (sqm.) | Min. Width (in meter) |
|---|---|---|---|
| 1 | Upto 12.00 meter | 1.2 | 0.9 |
| 2 | Upto 16.00 meter | 2.8 | 1.2 |
| 3 | Upto 22.00 meter | 4.0 | 1.5 |
| 4 | Upto 28.00 meter | 5.4 | 1.8 |
| 5 | Upto 34.00 meter | 8.0 | 2.4 |
| 6 | Above 34.00 meter | 9.0 | 3.0 |
58.6.21 Provision of toilets for visitors, and separate toilets for guards and drivers
58.6.22 Provision for harnessing Solar Energy for electricity shall be made in every building of more than 500sqm.
59. Maintenance
59.1 In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premises shall not be less than 5 (five) meters in width in order to allow easy access to fire engine. The gate shall fold back against the compound wall of the premises, thus leaving the exterior access way, within the plot, free for the movement of fire service vehicles. If archway is provided over the main entrances, the height of the archway shall not be less than 5 (five) meters.
59.2 The space set apart for providing access, within the premises shall in no case, be included in the calculation of requirements pertaining to parking spaces and other amenities required to be provided for the building.
59.3 Every access way shall be properly drained and lit to the satisfaction of the Authority. Manhole covers or any other fittings lay within the right of way of the access way shall be flushed with the finished surface level of it so as not to obstruct safe movement of men and vehicles.
59.4 Reconstruction, addition or alteration to any multi-storied building shall not be taken in a manner, which shall reduce the width of the



access way to a level below the minimum prescribed limit under these bye laws.