62. Semi-detached and row housing
62.1 Owners of adjacent similar dimension plot abutting a road may be permitted to construct row or semi-detached buildings.
62.2 The orientation of the row or semi-detached building shall preferably be such to ensure proper ventilation.
62.3 For semi-detached buildings over two adjacent plots, the setbacks, the height and the FAR shall be regulated by treating both the plots as one.
62.4 In case of row housing, the length of a row shall not exceed 50 m. along the road on which such houses abut. In case, the dwelling units in a row are scattered the maximum length of the row shall be 100 m.
62.5 The minimum size of the plot on which a unit of arow housing may be allowed shall be 50 sqm.
62.6 The height of such housing should not be more than 8.55m.
63. Shop-cum-residence
63.1 Where plots are in a row for shop-cum-residential purpose the Authority may allow construction of shop-cum-residential building without any side set backs up to a depth of 10 meters from the front exterior wall. Provided that no part of the building up to said depth is used for residential purpose on the ground floor. No building exceeding 12 meters in height shall be allowed to be constructed as a shop-cum-residential plot, unless so permitted under the zonal Development Plan, provided that the shop-cum-residence shall have 2/3rd of the total floor area used for shops. The FAR and other parameters shall conform to that specified for commercial buildings.
64. Cinema, Multiplex and Theatre building.-
64.1 The relevant provisions of the Jharkhand Cinemas (Regulation) Act, 1954 or any other relevant act shall apply for planning, designing and construction of Cinema and Theatre buildings.
64.2 No permission for construction of a building to be used as a cinema hail, theatre or auditoria for cultural show shall be granted unless the construction of such buildings conforms to the provisions of the Jharkhand Cinemas (Regulation) Act, 1954 or any other law in the subject for the time being in force in the State.
(1) x ,
64.3 All cinema, theatre or auditoria buildings shall conform to IS; 4898 - 1968 and acoustics design of such buildings shall adhere to the requirements of IS; 2526-1963.
64.4 Exits and fire safety requirements shall be in accordance with Part IV (Fire and life safety) of National Building Code of India, 2005.
65. Liquefied Petroleum Gas.-
65.1 Vacant space shall be maintained at all times, with the following distances for storage shed used for the storage of liquefied petroleum gas cylinders between any building, public space, public road or any adjoining property which may be built upon and the said storage shed. The minimum clear distance shall be as per Table 21.
Table - 21: Minimum distances required for storage shed of liquefied petroleum gas cylinders
| Quantity of Compressed Gas in Cylinders (Kg.) | Minimum Clear Distance to be Kept (meters) |
|---|---|
| 0-100 | 1 |
| 101-1000 | 3 |
| 1001-4000 | 5 |
| 4001-8000 | 7 |
| 8001-12000 | 9 |
| 12001-30,000 | 12 |
| Over 30,000 | 15 |
65.2 Not withstanding anything contained in the conditions specified above, cylinders containing liquefied petroleum gas exceeding 100 Kilograms but not exceeding 300 Kilograms may be kept in a storage shed forming part of, or attached to building, if it is separated there from by a substantial partition and the only means of access to it is from outside. Such a storage shed shall not be situated under any staircase or near other entrances to or exits from the rest of the building or other buildings. A shed used for storage of liquefied petroleum gas cylinders shall be surrounded by a suitable fence to prevent unauthorized persons from having access to the shed.