43.1 General
Every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of occupants, in case of fire or other emergency.
43.1.1 In every building exit shall comply with the minimum requirement of exit.
43.1.2 All exits shall be free from obstructions.
43.1.3 No building shall be altered so as to reduce the number, width of protection of exits to less than that required.
43.1.4 Exits shall be clearly visible and the routes to reach the exits shall be clearly marked and signposted to guide the population of floor concerned.
43.1.5 Adequate and reliable illumination shall be provided for exits.
43.1.6 Firefighting equipment shall be suitably located and clearly marked.
43.1.7 Alarm devices shall be installed to ensure prompt evacuation of the population concerned.
43.1.8 All exits shall provide continuous means of egress to the exterior of building or to an exterior open space leading to street.
43.1.9 Exits shall be so arranged that they may be reached without passing through another occupied unit.
43.2 Arrangement of exits
Exits shall be so located so that the travel distance on the floor shall not exceed 20 meters for residential, educational, institutional, and hazardous occupancies and 30 meters for assembly, business mercantile, industrial and storage occupancies.