(See Bye-law 65 (2))
Minimum thickness of external and partition masonry walls in public and industrial buildings:
| Height of wall (h) in metres | Length of wall to metres | Thickness t1 in centimetres | Thickness t2 in centimetres | ||
| Exceeding | Not exceeding | Exceeding | Not exceeding | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| - | 7.6 | Unlimited | 30 | - | |
| 7.6 | 9.1 | - | 13.7 | 30 | - |
| 7.6 | 9.1 | 13.7 | - | 40 | - |
| 9.1 | 12.2 | - | 9.1 | 30 | - |
| 9.1 | 12.2 | 9.1 | 13.7 | 40 | - |
| 9.1 | 12.2 | 13.7 | - | 50 | - |
| 12.2 | 15.2 | - | 9.1 | 50 | - |
| 12.2 | 15.2 | 9.1 | 13.7 | 60 | - |
| 12.2 | 15.2 | 13.7 | - | 70 | - |
| 15.2 | 18.3 | - | 13.7 | 60 | - |
| 15.2 | 18.3 | 13.7 | - | 70 | - |
| 18.3 | 21.3 | - | 13.7* | 60 | - |
| 18.3 | 21.3 | 13.7 | - | - | 70 |
| 21.3 | 24.4 | - | 13 | 60 | - |
| 21.3 | 24.4 | 13.7* | - | - | 70 |
*The extra 10 cm. (or 4") thickness of wall is required because the length exceeds 13.7 m. (or 45’) which may be confined to plasters properly distributed, of which the collective widths amount to at least a quarter of total length of the wall.
Note: t1 is the thickness at the base of a wall of any length and not greater than 18.3 m. (or 60') in height and of any height and length not greater than 13.7 m. (or 45').
t2 is the thickness at the base of wall of height greater than 18 m. (or 60’) and of length greater than 13.7 m. (or 45’).
P. JANAKI, Under Secretary to Government(Housing).
online publication at “http://styandptg.puducherry.gov.in” Government Central Press Directorate of Stationery and Printing Puducherry-9