(1) (a) Multi-Storeyed Building or High Rise Building- A building above 4 stories, and/or a building exceeding 15 meters or more in height above the average level of front road is termed as Multi-Storeyed Building or High Rise Building.
(b) Site extent: The minimum extent of site for construction of multi-storeyed buildings shall not be less than 1000 sq.m.
(c) Road width : The site shall either abut on a road not less than 15.0 m. in width or gain access from a public road of not less than 15.0 m. through a part of the site which can be treated as an exclusive passage of not less than 15.0 m. in width.
Explanation: For the purpose of this paragraph, road width means average road width in front of the site in question and for a few meters on either side for purpose of measurements to be taken in conjunction with the average width of that road in general. To cite examples and illustrate the principle:
(i) If the road over its general length is of 15.0 m. width but because of some kinks in front of the site one end is 14.8 m. and the other end is 15.2 m. is acceptable.
[ PART-I
(ii) If the general road is of width less than 15.0 m., but only widens opposite to or nearer to the site is more than 15.0 m., is not acceptable.
(iii) If the road is generally of 15.0 m. width up to a considerable length on one side, but discontinues and narrows into a road of smaller width on the other side of the site in question and the plot owner is willing to leave enough space for continuity of 15.0 m. road in front of his site, this will have to be checked and decided on case by case.
(iv) If the general road width is less than 15.0m. and the site owner merely agrees to leave enough space to have 15.0m. in front of his site only, this is not acceptable.
Note: All road width measurements shall be of the road as designed and laid and the existence of unauthorised encroachments for which no patta has been given shall not affect adversely the consideration that the road as "originally laid was wide".
(2) Floor Area Ratio and plot coverage: The maximum permissible F.A.R. and plot coverage shall be as given below:
| Sl.No | Max. permissible plot coverage | Maximum permissible FAR |
|---|---|---|
| 1. | Up to 45% | 250 |
(3) Set-back spaces:
(a) There shall be space permanently open to sky forming an integral part of the site and of a minimum extent specified in this regulation, between each of the boundaries of the site and any building proposed within the site and also between building and any building proposed within the site.
(b) The extent of set-back space shall be as follows:
| Height of building above ground level.( in metres)(1) | Minimum required set back space from the property boundary. ( in metres)(2) | Spacing between blocks in the case of group development. (in metres)(3) |
|---|---|---|
| Above 15.0 m. up to 30.0 m. | 7 | 6 |
Explanation:
(i) For the purpose of these regulation, group development is one which has two or more blocks of buildings in a particular site irrespective of whether these structures are interconnected or not. Any inter-link between the structures in terms of connecting corridors shall not be construed as making any two structures into one. However if these blocks are connected solidly at least for 1/3rd the width of any one block on the connecting side then such blocks shall be construed as a single block.
(ii) In the cases where street alignment has been prescribed the front space shall be left from the street alignment.
(c) The space specified above shall be kept open to sky and free from any erection or projection (such as sunshade / balcony) of any building other than a fence or a compound wall provided that these open yards may be used for the provision of access ways to the building's parking facilities.
(d) A watchman or caretaker booth or kiosk or power transformer shall be permitted in the set back space at ground level after leaving 7.0 m. clear set-back from the main structure provided its height above ground level does not exceed 4.0 m. provided that the height restriction shall not apply for an open transformer.
(4) Height of building: One and half times the width of the abutting road provided that the height may be exceeded to the extent of 1.0 m. for every 30 cm. by which the building is set back from the street or 30.0 m. which ever is less.
PART-I
297
(5) Parking and Parking facilities:
For the use of the occupants and of persons visiting the premises for the purpose of profession, trade, business, recreation or any other work, parking spaces and parking facilities shall be provided within the site to the satisfaction of the Authority and conforming to the standards specified in the Annexure -X.
(6) Vehicular access within the site: The vehicular access way within the site shall have a minimum width of 7.2 m. and such vehicular access shall be available for every building block in the site. Further it shall be a clear width of open to sky and no projection in structured over it is permissible.
(7) Corridor width: The corridor serving as access for units in the development in whichever floor they may be situated shall not be less than the standards prescribed in clause 38(2) of Chapter-III.
(8) Basement floor :
(a) The height of the basement floor shall not exceed 1.20 m. above ground level and the head room shall be minimum of 2.40 m. Where the basement height exceeds 1.20 m., the same shall be included in the total floor area of the building for calculation of floor space index / floor area ratio etc.
(b) No part of the basement shall be constructed in the minimum required set back spaces.
(c) In cases where second basement is proposed for parking and incidental uses, sufficient provision for lighting and ventilation and also for protection from fire to the satisfaction of the Fire Service Department shall be made.