The following shall not be counted towards F.A.R. calculation:-
(i) Areas covered by stair-case rooms and lift rooms and passages thereto above the top most storey, architectural features, chimneys, elevated tanks (provided its height below the tank from the floor does not exceed 1.5 m.) and WC (area not exceeding 10 sq.m.).
(ii) Stair case and lift rooms and passage thereto in the stilt parking floor.
(iii) Lift wells in all the floors except ground floor.
(iv) Area of the basement floor / floors used for parking.
(v) Area of the stilt parking floor provided its clear height (between lower floor and the bottom of the roof beam) does not exceed 2.4 m. and it is open on sides, and used for parking.
(vi) Area of structures exclusively for, accommodating machineries for water treatment plant and effluent treatment plant proposed with clearance from the Puducherry Pollution Control Board.
(vii) Areas covered by service ducts, and garbage shaft, chimneys in industries.
(viii) Area of balcony / Service verandah to an extent of 5% of each dwelling units area in case of residential buildings and 5% of room area in case of Hotels and lodges.
(ix) Porches / Canopies / Porticos / Loft.
(x) Service floor with height not exceeding 1.5m.
(xi) Area of fire escape staircase and cantilever fire escape passages.
(xii) The following services and incidental structures necessary to the principle use subject to a maximum of 10 per cent. of the total floor area.
(a) Area of one office room not exceeding 15 sq.m for co-operative housing society or apartment / building owners association in each block.
(b) Servant's / drivers bath room and water closet (not exceeding 20 sq.m.) for each block in cases of special building, Group Development and Multi-Storeyed Building at ground floor / stilt parking floor.
(c) Gymnasium of 150 sq.m in floor area.
(d) area covered by
(i) Meter room in Ground floor or stilt parking floor.
(ii) Air-conditioning plant room in basement or ground floor.
(iii) Electrical / transformer room in Ground floor or Stilt parking floor.
(iv) Watchmen or caretaker booth / room in Ground floor / stilt parking floor.
(v) Pump room in Ground floor or stilt parking floor.
(vi) Generator room in basement floor or ground floor or stilt floor.
(vii) Lumber room in basement floor or ground floor.
(viii) A.H.U. in all the floors.
(ix) Electricals switch gear rooms in all the floors.
(e) Area of one room in ground floor of residential and commercial multi-storeyed building, special buildings, Group Developments for separate letter boxes.
[ PART-I]
To Provide Facilities in the Public Building excluding Domestic Buildings for Differently abled Persons
1. Definitions:
| Ambulant Disabled People: | Disabled who are able to walk but who may depend on prostheses (Artificial Limbs) orthoses (Calipers), Sticks, crutches or walking aids. |
|---|---|
| Non-Ambulant Disabled People: | Disabled people with impairments that confine them to wheelchair. |
| Wheel Chair: | Chair used by disabled people for mobility. |
(i) Size of small wheel chair: 750 × 1050 mm.
(ii) Size of large wheel chair: 800 × 1500 mm.
2. Scope :
These bye-laws are applicable to public buildings and exclude domestic buildings.
Building which shall provide access to ambulant disable and Non-Ambulant disabled are listed below. Distinction is made for buildings to be designed for the use of large wheel chairs and small wheel chair.
3. Building to be designed for Ambulant Disabled People:
Higher Secondary School, Conference Hall, Dance Halls, Youth Centres, Youth Clubs, Sport Centres, Sport Pavilions, Boat Club Houses, Ice Rinks, Bowling Centres, Swimming Pools, Police Stations, Law Courts, Courts Houses, Sport Stadiums, Theaters, Concert Halls, Cinemas, Auditoria, Small Offices (the maximum plinth area 1400 sqm.) Snack Bars, Cafes and banqueting rooms (for capacity above 50 diners).
Note:
(i) In sport stadiums provisions shall be made for non-ambulant spectators (small wheel chair)
(ii) @ 1:1000 up to 10,000 spectators and @ 1:2000 for spectators above 10,000.
(iii) In Theaters, Concert Halls, Cinemas and Auditoria, provisions shall be made for non-ambulant spectators (Small Wheel Chairs) @ 1/250 up to 1000 spectators and 1/500 for spectators above 1000.
4. Building to be designed for Non-Ambulant Disabled People:
Schools for physically handicapped, cremation, buildings as mentioned in 3, Botanical Gardens, Religious Buildings, Old People Clubs, Village Halls, Day Centers, Junior Training Centers, Post Offices, Banks, Dispensaries, Railway Stations, Shops, Super Markets, and Departmental Stores.
Note: Large Wheel chair criteria shall be applicable on ground floors of the following building, post offices, banks, dispensaries, railway station, shops, supermarkets, and departmental stores.
5. Building to be designed for Non-Ambulant People (using small wheel chairs):
6.2 Site Planning:
Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm. wide having regular surface without any steps. The parking of vehicles of disabled people two equivalent car spaces (E.C.S.) shall be provided near entrance of 30.0 m. from building entrance.
7. Approach to Plinth Level:
Ramp shall be provided to enter the building, minimum width of ramp shall be 1800 mm. with maximum gradient 1:12, length of ramp shall not exceed 9.0 m. having 900 mm. high hand rail on both sides extending 300 mm. both sides of ramps. Minimum gap from the adjacent wall to the handrail shall be 50 mm. Entrance landing shall be provided adjacent to ramp with the minimum dimension 1800 X 2000 mm. Minimum Clear opening for the entrance door shall be 1000 mm. Threshold shall not be raised more than 12 mm. For stepped approach size of tread shall not be less than 275 mm. and maximum riser shall be 150 mm.
8. Stairways:
Height of the riser shall not be more than 150 mm. and width of the tread not less than 275 mm, nosing if provided shall not extend beyond 25 mm. Maximum number of risers on a flight shall be limited to 12 Nos.
9. Lifts:
Whenever lift is required as per bye-laws, provision of at-least one lift shall be made for Non-Ambulant disabled (using small wheel chairs with the following minimum dimensions of lift).
Clear internal depth 1090 mm.
Clear internal width 1750 mm.
Entrance door width 910 mm.
A handrail not less 600mm. long at 1000mm. above floor level shall be fixed adjacent to the control panel.