10.1 One special W.C. in a set of toilet shall be provided for the use of disabled. No additional provision of W.C. is to be made for disabled.
Size of the W.C. shall depend on the category of disabled for whom it has been provided.
All doors in W.Cs shall open outside.
The type of W.C. shall be European with seat height as 500 mm.
Handrails, where provided shall have min 25 mm. dia.
10.2 Provision of W.Cs in buildings without lift:
Provision of special W.C. shall be made on all floors for buildings designed for ambulant disabled persons. For buildings designed for non-ambulant disabled special W.C. shall be provided at Ground Floor. Size of W.C. shall depend on the type of wheel chair used by the disabled.
10.3 Provisions of W.Cs in building with lift:
Provision of Special W.C. shall be made on all floors. Size will depend on the category of disabled for whom it has been provided.
10.4 Toilet Details:
10.4.1 For Toilets Designed for ambulant Disabled:
The minimum size of W.C. shall be 1075 x 1650 mm. with a minimum depth of 1450 mm. from entry door 900 mm. Long handrail on the side closer to W.C. with a clear width between the handrails shall be 900 mm. and height of handrails shall be 800 mm. from floor level. Minimum size of the clear door opening shall be 780 mm.
[ PART-I
10.4.2 For Toilets Designed for Non-Ambulant Disabled Small Wheel Chair:
The minimum size of W.C. shall be 1350 x 1500 mm. with a minimum depth of 1500 mm. from entry door. 900 mm. long handrail on the side closer to W.C. shall be provided. To provide movement space for wheel chair, W.C. seat shall be fixed towards one side to the opposite adjacent wall. The centerline of W.C. from the adjacent wall shall be 400 mm. and minimum 950 mm. from the other wall. Minimum size of the clear door opening shall be 780 mm.
10.4.3 For Toilets Designed for Non-Ambulant Disabled Using Large Wheel Chair:
The minimum size of W.C. shall be 1500 X 1750 mm. with a minimum depth of 1750 mm. for entry door. 900 mm. long handrail on the side wall closer to W.C. shall be provided. To provide movement space for wheel chair, W.C. seat shall be fixed towards one side of the opposite wall. The centerline of the W.C. from the adjacent wall shall be 400 mm. and a minimum of 1100 mm. from the other wall. Minimum size of clear door opening shall be 860 mm.