60. STRUCTURAL SAFETY :
In case of small Developments (ie., ordinary or commercial buildings, industrial or institutional buildings upto G+1 floors in height and with floor area (both existing and proposed) not exceeding 300 sq.m.), the provisions in this part of the bye-laws related to structural design, submission of working drawings / structural drawings, etc. shall not apply except that all such applications and plans for these small developments shall be signed by the owner/developer, and the Registered Engineer / Architect shall certify that the structural design of the small developments has been done as per the latest Indian standard Specifications and the N.B.C.
61. STRUCTURAL DESIGN :
The structural design of foundation, masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall be carried out in accordance with Part-VI structural design, section-1 loads, section-2 foundation, section-3 wood, section-4 masonry, section-5 concrete and section-6 steel of National Building Code of India taking into consideration all relevant Indian Standards/specifications prescribed by Bureau of Indian Standards including the Indian Standard given in I.S.-Code 1893-1984, 13920-1993, 4326-1993, 13828-1993, 13827-1993 and 13935-1993 for structural safety.
1. QUALITY OF MATERIALS AND WORKMANSHIP :
All material and workmanship shall be of good quality conforming generally to the accepted standards of Public Works Department and Indian Standard Specification and codes as included in Part-V Building Materials and Part-VII Constructional Practices and Safety of National Building Code of India.
PART-I
237
2. ALTERNATIVE MATERIALS, METHODS OF DESIGN AND CONSTRUCTION AND TESTS :
The provision of the Bye-laws are not intended to prevent the use of any material or method of design or construction not specifically prescribed by the bye-law provided any such alternative has been approved. The building materials approved by B.I.S. or any statutory body will form part of the approved building material and technology as part of the Bye-laws.
3. BUILDING SERVICES :
The Planning design and installation of electrical installations, air-conditioning installation of lifts and escalators can be carried out in accordance with Part-VIII, Building Services, section-2 electrical installation, section-3 air conditioning and heating, section-5 installation of lifts and escalators of National Building Code of India. However deviations from National Building Code may be done as per good Engineering practices approved by the Competent Authorities.
4. PLUMBING SERVICES :
The planning, design, construction and installation of water supply, drainage and sanitation and gas supply shall be in accordance with Part -IX Plumbing Services, section -1 water supply, section -2, drainage and sanitation and section -3, gas supply of National Building Code of India.
- Structural standards: (1) All structures shall be so designed, built and maintained that under the conditions of dead and live loading, the stresses in any of the materials of construction or in the material on which a structure rests shall not exceed the permissible limits as laid down in the National Building Code published from time to time.
(2) When an existing building or other structure is enlarged or otherwise altered, the portions thereof affected by such enlargements or alterations shall be strengthened where necessary, so that all loads will be supported safely without exceeding the permissible stresses prescribed for the materials of construction and for the structural members in the National Building Code published from time to time.
(3) No building, the external walls of which are timber framed construction shall be erected, re-erected or altered materially so as to consist of more than a ground floor and one upper storey; provided that the Planning Authority may by special order, grant permission for the erection of such a building of two storeys or for the construction of one or more additional storeys if satisfied that such buildings will be, or are of thoroughly sound material and construction and can safely support the same.
-
Live loads, wind loads and seismic loads in buildings: Live loads, wind loads and seismic loads shall conform to those specified in the National Building Code published from time to time.
-
Foundations.—(1) The foundations of every building shall be so designed and constructed as to sustain the dead load of the building and the super imposed load including seismic load as prescribed in N.B.C. and to transmit the loads to and distribute them over the soil in such a manner that pressure brought to bear on the soil by these loads shall not exceed the safe bearing capacity of the soil. The safe bearing capacity of the commonly occurring rocks and soils are given in Schedule-I.
(2) In the design of basement walls and similar approximately vertical structures below ground level, provision shall be made for the lateral pressure of the adjacent soil including seismic force and the walls shall be designed as retaining walls. Due allowance shall be made for possible surcharge due to fixed or moving loads. When a portion or the whole of the adjacent soil is below a free water surface, computations shall be based on weight of the soil diminished by buoyancy plus hydrostatic pressure.
(3) In the design of basement floors and similar approximately horizontal constructions below ground level, the upward pressure of water, if any, shall be taken as the full hydrostatic pressure applied over the entire area. The hydrostatic head shall be measured from the underside of the construction.
68. 1 Exemptions:
These directives shall not apply to:
(a) Buildings that do not use either electricity or fossil fuel; or
(b) Equipment and portions of building systems that use energy primarily for manufacturing processes.
68. 2 Safety, Health and Environmental Codes Take Precedence:
Where these directives are contrary to any of the provisions of laws relating to safety, health or environment, the provisions of safety, health or environmental laws shall apply.