(1) For new construction: Provisions shall be made for under ground tank for the storage of water, having capacity at 200 litres per person with adequate pumping arrangements to supply water to upper floors. Filtered water connection will be allowed only for use of drinking and bathing needs. For other purposes i.e. flushing and gardening etc., the individual shall be required to have own arrangements of tube well water within the premises. While according sanction to Layout Plan, the Authority shall make a special mention that provision for space shall be kept for the construction of under ground reservoir of adequate capacity along with booster pumping station.
(2) Arrangements as given in 1 above also be provided in Group Housing Societies.
(3) The plumbing arrangement in case of new constructions shall be made in a way that the potable water shall be used for drinking cooking & bathing only and for rest of the uses, provision for ground water can be made with dual piping system.
(4) Low capacity cistern should preferably be provided instead of normal 12.5 litres capacity.
-
Water Harvesting: Water harvesting through storing of water runoff including rainwater in all new buildings of plinth area 100 sq.m. or plots of 200 sq.m. and above will be mandatory. The plans submitted to the local Authority shall indicate the system of storm water drainage along with points of collection of rain water in surface reservoirs or in recharge wells as per the specifications given in Annexure-VII-A.
-
Recycling of waste water: All building having a minimum discharge of 10,000 litres and above per day shall incorporate waste water recycling system as per the specification given in the Annexure-VII-B.
-
Installation of Solar Assisted Water Heating System in Buildings:
(i) No new building in the following categories in which there is a system of installation for supplying hot water shall be built unless the system of the installation is also having an auxiliary solar assisted water heating system:
(a) Hospitals and Nursing Homes.
(b) Hotels, Lodges, and Guest Houses, Group Housing with the plot area of 4000 sq.m.
(c) Hostels of Schools, Colleges and Training Centres with more than 100 Students.
(d) Barracks of armed forces, paramilitary forces and police.
(e) Individual residential buildings having more than 150 sq.m. plinth area.
(f) Functional Buildings of Railway Stations and Air Ports like waiting rooms, retiring rooms, rest rooms, inspection bungalows and catering units.
(g) Community Centres, Banquet Halls, Kalyana mandapam and building for similar use.
PART-I
303
(ii) Definitions:
| (i) | “Solar Assisted Water Heating System” | A device to heat water using solar energy as heat source. |
|---|---|---|
| (ii) | “Auxiliary back up” | Electricity operated or fuel fired boilers/systems to heat water coming out from solar water heating system to meet continuous requirement of hot water. |
| (iii) | “New Building” | Such buildings of above said categories for which construction plans have been submitted to the Authority for clearance. |
| (iv) | Existing building” | Such buildings, which are licensed to perform their respective business. |
(iii) Installation of Solar Water Heating System:
(a) New Buildings: Clearance of plan for the construction of new buildings of the aforesaid categories shall only be given if they have a provision in the building design itself for an insulated pipeline from the rooftop in the building to various distribution points where hot water is required. The building must have a provision for continuous water supply to the solar water heating system. The building should also have open space on the rooftop, which receives direct sunlight. The load bearing capacity of the roof should at least be 50 kg. per sq.m. All new buildings of above said categories must complete installation of solar water heating systems before obtaining necessary licence to commence their business.
(b) Existing Buildings: Installation of Solar Assisted Water Heating System in the existing building shall be made mandatory at the time of change of use to above said category provided there is a system or installation for supplying hot water.
(iv) Capacity: The capacity of solar water heating system to be installed on the building of different categories shall be decided in consultation with the local bodies/Authorities concerned. The recommended minimum capacity shall not be less than 25 liters per day for each bathroom and kitchen subject to the condition that maximum of 50% of the total roof area is provided with the system.
(v) Specifications: Installation of Solar Assisted Water Heating Systems shall conform to BIS specification IS 12933. The solar collectors used in the system shall have the BIS certification mark.
(vi) Auxiliary System: Wherever hot water requirement is continuous, auxiliary heating arrangement either with electric elements or oil of adequate capacity can be provided.