1. OFFICE BUILDING
| Sl.No. | Fixtures | Public Toilets | Staff Toilets | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Executive Rooms and Conference Halls in Office BuildingsToilet suite comprising one W.C., one washbasin (with optional shower stall if building is used round the clock at user's option)Pantry optional as per user requirement | Unit could be common for Male / Female or separate depending on the number of user of each facility | For individual officer rooms | ||
| (ii) | Main office toilets for Staff and Visitors | ||||
| a) Water - closets | 1 per 25 | 1 per 15 | 1 per 25 | 1 per 15 | |
| b) Ablution tap with each water-closet | ← lin each water-closet → | ||||
| c) Urinals | Nil up to 6 -1 for 7-202 for 21-453 for 46-704 for 71-1003%2.5%1 per 25 | 1 per 25 | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-1003%2.5%1 per 25 | -1 per 25 | |
| For persons 101-200 addFor persons over 200 add | |||||
| d) Washbasins | |||||
| e) Drinking water fountain | 1 per 100 | 1 per 100 | 1 per 100 | 1 per 100 | |
| f) Cleaner's sink | ← 1 per floor → | ||||
PART-I]
271
2. FACTORIES
| Sl.No. | Fixtures | Offices / Visitors | Workers | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Water-closets (Workers and Staff) | 1 for upto 252 for 26-353 for 36-654 for 66-100 | 1 for upto 152 for 16-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 |
| For person 101-200 add | 3% | 5% | 3% | 5% | |
| For person over 200 add | 2.5% | 4% | 2.5% | 4% | |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| (iii) | Urinals | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - |
| For persons 101-200 add | 3% | 3% | |||
| For persons over 200 add | 2.50% | 2.50% | |||
| (iv) | WashbasinsWashbasins in rows or troughsand taps spaced 750mm c/c | 1 per 25 or part thereof | 1 per 25 or part thereof | 1 per 25 or part thereof | 1 per 25 or part thereof |
| (v) | Drinking water fountain | 1 per every 100 or part thereof with minimum one on each floor | 1 per every 100 or part thereof with minimum one on each floor | ||
| (vi) | Cleaner's sink | 1 on each floor | 1 on each floor | 1 on each floor | 1 on each floor |
| (vii) | Showers / Bathing rooms | As per trade requirements | |||
| (viii) | Emergency shower and eye wash fountain | - | - | 1 per every shop floor per 500 persons | |
NOTE: For factories requiring workers to be engaged in dirty and dangerous operations or requiring them to being extremely clean and sanitized conditions additional and separate (if required so) toilet facilities and if required by applicable Industrial and Safety Laws and the Factories Act must be provided in consultation with the user.
[ PART-I]
- CINEMA, MULTIPLEX CINEMA, CONCERTS AND CONVENTION HALLS, THEATRES
| Sl.No. | Fixtures | Public | Staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Water-closets | 1 per 100 upto 400Over 400 add at 1 per 250 or part thereof | 3 per 100 upto 200Over 200 add at 2 per 100 or part thereof | 1 for upto 15 | 1 for upto 12 |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| (iii) | Urinals | 1 per 25 or part thereof | - | Nil up to 61 for 7-202 for 21-45 | - |
| (iv)(v) | WashbasinsDrinking water fountain | 1 per 200 or part thereof | 1 for upto 152 for 16-35 | 1 for upto 122 for 13-25 | |
| ←1 per 100 persons or part thereof → | |||||
| (vi) | Cleaner's sink | ←1 per floor → | |||
| (vii) | Showers / Bathing rooms | ←As per trade requirements → | |||
NOTE: (1) Some WCs may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
PART-I]
273
4. ART GALLERIES, LIBRARIES AND MUSEUMS
| Sl.No. | Fixtures | Public | Staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Water-closets | 1 per 200 upto 400 | 1 per 100 upto 200 | 1 for upto 15 | 1 for upto 12 |
| Over 400 add at 1 per 250 or part thereof | Over 200 add at 1 per 150 or part thereof | 2 for 16-35 | 2 for 13-25 | ||
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| (iii) | Urinals | 1 per 50 | - | Nil up to 6 -1 for 7-202 for 21-45 | |
| (iv) | Washbasins | 1 per every 200 or part thereof. For over 400, add at 1 per 250 persons or part thereof | 1 per every 200 or part thereof. For over 200, add at 1 per 150 persons or part thereof | 1 for upto 15 1 for upto 122 for 16-35 2 for 13-25 | |
| (v) | Drinking water fountain | ←——— 1 per 100 persons or part thereof → | |||
| (vi) | Cleaner's sink | ←——— 1 per floor, Min → | |||
| (vii) | Showers / Bathing rooms | ←——— As per requirements → | |||
NOTE: (1) Some W.C.'s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
[ PART-I]
5. HOSPITALS WITH INDOOR PATIENT WARDS
| Sl.No. | Fixtures | Patient Toilets | Staff Toilets | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Toilet suite comprising one WC and one washbasin and shower stall | Private room with upto 4 patients | For individual doctor's / officer's rooms | ||
| For General Wards, Hospital Staff and Visitors | |||||
| (ii) | Water-closets | 1 per 8 beds or part thereof | 1 per 8 beds or part thereof | 1 for upto 152 for 16-35 | 1 for upto 122 for 13-25 |
| (iii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| (iv) | Urinals | 1 per 30 beds | - | Nil upto 61 for 7-202 for 21-45 | - |
| (v) | Washbasins | 2 per every 30 beds or part thereof. Add 1 per additional 30 beds or part thereof | 1 for upto 152 for 16-35 | 1 for upto 122 for 13-25 | |
| (vi) | Drinking water fountain | 1 per ward | 1 per 100 persons or part thereof | ||
| (vii) | Cleaner's sink | 1 per ward | - | ||
| (viii) | Bed pan sink | 1 per ward | - | ||
| (ix) | Kitchen sink | 1 per ward | - | ||
NOTE:
(1) Some W.C.'s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
(3) Provision for additional and special hospital fittings where required shall be made.
PART-I
275
6. HOSPITALS OUTDOOR PATIENT DEPARTMENT
| Sl.No.(1) | Fixtures(2) | Patient Toilets | Staff Toilets | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| (i) | Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h) | For upto 4 patients | For individual doctor's / officer's rooms | ||
| (ii) | Water-closets | 1 per 100 persons or part thereof | 2 per 100 persons or part thereof | 1 for upto 152 for 16-35 | 1 for upto 122 for 13-25 |
| (iii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| (iv) | Urinals | 1 per 50 persons or part thereof | - | Nil upto 61 for 7-202 for 21-45 | - |
| (v) | Washbasins | 1 per 100 persons or part thereof | 2 per 100 persons or part thereof | 1 for upto 152 for 16-35 | 1 for upto 122 for 13-25 |
| (vi) | Drinking water fountain | 1 per 500 persons or part thereof | 1 per 100 persons or part thereof | ||
| NOTE: (1) Some W.C.'s may be European style if desired.(1) Male population may be assumed as two-third and female population as one-third.(2) Provision for additional and special hospital fittings where required shall be made.7. HOSPITALS, ADMINISTRATIVE BUILDINGS | |||||
| Sl.No. | Fixtures | Staff Toilets | |||
| Male | Female | ||||
| (1) | (2) | (3) | (4) | ||
| (i) | Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h) | For individual doctor's / officer's rooms | |||
| (ii) | Water-closets | 1 per 25 persons or part thereof | 1 per 15 persons or part thereof | ||
| (iii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | ||