(a) The height of basement floor shall not exceed 1.2 m. above the adjacent ground level and the headroom shall be minimum 2.4 m.
(b) No part of the basement shall be constructed in the minimum required set backspaces, required for the movement of fire fighting vehicles / equipments.
(c) In cases where second basement is proposed for parking and incidental uses, sufficient provisions for lighting and ventilation and also for protection from fire to the satisfaction of Fire Service Department shall be made.
(d) During the construction of the basement floor, it shall be sole responsibility of the planning permission holder to ensure that the building / structure in the adjoining sites are not weakened / damaged.
(24) Security Deposit:
The applicant shall deposit a sum at the rate of ₹ 50 per sq.m. of floor area as a refundable non-interest earning security and earnest deposit. The deposit shall be refunded on completion of development as per the approved plan as certified by Planning Authority; if not, it would be forfeited.
Annexure XISpecial Buildings and Group Developments
(A). Special Buildings:
The following regulations shall apply to "Special Buildings"
Explanation -
(1) "Special Buildings" means
(a) Residential / commercial / Industrial buildings with more than 2 floors; or
(b) Residential building with more than 6 dwelling units or
[ PART-I
(c) Commercial building exceeding floor area of 300 sq.m.or
(d) Buildings like education, assembly, Institutional, public and semi-public, and mixed occupancies with any of the aforesaid occupancies irrespective of number of floors.
(2) The minimum width of the road on which the site abuts shall be 9.0 m., however a building for residential use may be permitted on a site abutting or gaining access from a 6 m. wide road.
Note: Kalyana mandapam / Reception hall, cinema theatres and Multiplex complexes shall be permitted only along roads of width of minimum 12.0 m.
Explanation: The road width means average road width in front of the plot in question and for a few metres on either side for purposes of measurements to be taken in conjunction with the average width of that road in general.
(3) If the site does not directly abut a public road but gains access through a private exclusive passage or through part of the plot which can be treated as a passage from a public road of minimum width as prescribed above, the minimum width of such passage shall be as follows:
Sl.No.
Description
Minimum Width
1.
When it is intended to serve six dwellings or up to 600 sq.m. of commercial building and the length of the passage does not exceed 80.0 m.
3.6 m.
2.
When it is intended to serve up to 8 dwellings or up to 2,400 sq.m. of commercial building and the length of the passage does not exceed 100 .0 m.
4.8 m.
3.
When it is intended to serve not more than 10 dwellings or up to 3000 sq.m. of commercial building and the length of passage does not exceed 120.0 m.
7.2 m.
4.
When it is intended to serve not more than 20 dwellings or up to 6000 sq.m. of commercial building and the length of passage does not exceed 240.0 m.
9.0 m.
5.
When it is intended to serve more than 20 dwellings or more than 6000 sq.m. of commercial building
10.0 m.
(4)(a) Residential / predominantly residential building in the plot area less than 500 sq.m. :
S1.No
Description
Continuous Building Areaany where within Planningarea
Other areas in Planning area.
1
2
3
4
A
Minimum plotextent
50 sq.m.
100 sq.m.
B
Minimum Plotfrontage / width
4.5 m.
6.0 m.
C
MaximumHeight
One and half times the width of the abutting road provided that the heightmay be exceeded to the extent of 1.0 m. for every 30 cm. by which thebuilding is set back from the street or 15.0 m. whichever is less except inareas set apart specifically for multistoried buildings.
D
MaximumCoverage
75%
70%
E
Maximum F.A.R.
150
F
MinimumSetbacks
It shall be from the property boundary.
(i)
Front Setback
A butting Road width
Set back
15.25 m. and below
3.0 m.
Above 15.25 m & up to 30.5 m.
4.5 m.
Above 30.5 m.
6.0 m.
(ii)
Side Setback
Nil
Plot widthUp to 6.0 m.
Side set back1.0 m. on one side
Above 6.0 m., up to 9.15 m.
1.0 m. on either side
Above 9.15 m.
1.5 m. on either side
(iii)
Rear Setback
Nil
1.5 m.
PART-I
285
(b) Residential / Predominantly Residential buildings in the plot area more than 500 sq.m.
F
Minimum Setbacks
It shall be from the property boundary.
(i)
Front Setback
Abutting Road width
Set back
15.25 m. and below
3.0 m.
Above 15.25 m. & up to 30.5 m.
4.5 m.
Above 30.5 m.
6.0 m.
(ii)
Side Setback
Nil
3.0 m. on either side
(iii)
Rear Setback
Nil
1.5 m
(5)(a) Commercial or predominantly commercial building in plot area less than 500 sq.m.:
Sl.No
Description
Continuous Building Area anywhere within Planning area
Other areas in Planning area.
1
2
3
4
A
Minimum plot extent
80 sq.m.
100 sq.m.
B
Minimum Plot frontage / width
4.0 m.
6.0 m.
C
Maximum Height
One and half times the width of the abutting road provided that the height may be exceeded to the extent of 1.0 m. for every 30 cm. by which the building is set back from the street or 15.0 m. whichever is less except in areas set apart specifically for multistoried buildings.
D
Maximum Coverage
75%
70%
E
Maximum F.A.R.
150
F
Minimum Setbacks
It shall be from the property boundary.
(i)
Front Setback
Abutting Road width
Set back
15.25 m. and below
3.0 m.
Above 15.25 m. & up to 30.5 m.
4.5 m.
Above 30.5 m.
6.0 m.
(ii)
Side Setback
Nil
Plot width
Side set back
Up to 6.0 m.
1.0 m.
Above 6.0 m., up to 9.0 m.
1.0 m. on one side
Above 9.0 m.
1.5 m. on either side
(iii)
Rear Setback
Nil
1.75 m.
(b) Commercial or predominantly commercial buildings in plot area exceeding 500 sq.m
F
Minimum Setbacks
It shall be from the property boundary.
(i)
Front Setback
Abutting Road width
Set back
15.25 m. and below
3.5 m.
Above 15.25 m. & up to 30.5 m.Above 30.5 m.
4.5 m.6.0 m.
(ii)
Side Setback
Nil
3.0 m. on either side
(iii)
Rear Setback
3.0 m.
[ PART-I]
(6) Assembly / Institutional / Educational buildings / Religious buildings ( more than 500 sq.m. floor area) :-
Sl.No
Description
Continuous Building Areaanywhere within Planning area
Other areas inPlanning area.
1
2
3
4
A
Minimum plot extent
500 sq.m.
1000 sq.m.
B
Minimum Plot frontage / width
20.0 m.
20.0 m.
C
Maximum Height
One and half times the width of the abutting road provided that the height may be exceeded to the extent of 1.0 m. for every 30 cm. by which the building is set back from the street or 15.0 m. whichever is less except in areas set apart specifically for multistoried buildings.
D
Maximum Coverage
50%
40%
E
Maximum F.A.R.
150
F
Minimum Setbacks
It shall be from the property boundary.
(i)
All round setbacks for plot area less than 500 sq.m.
3.0 m.
(ii)
All round setbacks for plot area more than 500 sq.m.
6.0 m.
(7) Structures permissible in the minimum prescribed Front setback, Side setback and Rear set back are given in the Clause 39 (4) of the chapter -III of the Building Bye-laws.
(8) The minimum width of corridor shall be as given in the Clause 38(2) of the chapter-III of Building Bye-laws.
(9) Parking spaces shall be provided within the site conforming to the regulations given in the Annexure -X.
(10) Rainwater harvesting provisions as prescribed in the Annexure-VII shall be provided.
(11) Special regulations for physically disabled stated in the Annexure-XVII shall be adhered to.
(12) Solar energy capture provisions as prescribed in the Annexure -XVIII shall be provided where ever applicable.
(13) The reservation of land for community recreational purposes such as park or play ground shall be as required in these regulations specified in Annexure-II.
(14) If the building is constructed on stilts and the stilt floor is to be used for parking, the minimum clear height of the floor (between the lower floor and the bottom of the beam) shall not exceed 2.4 m. and it shall not be enclosed for use as garages; if it is enclosed it shall be counted for F.A.R. and number of floors for the purpose of defining special building / Multistoreyed building.
(15) In respect of special buildings exceeding 2 floors in height, a part or whole of it shall be on stilts and the stilt floor shall be reserved for parking.
(16) If a special building contains more than one use and the allowability of the built space with reference to the abutting road width and exclusive passage width shall be decided based on the number of dwellings for the residential use and equivalent floor area allowable for commercial and other uses.
(17) Vehicular ramp in set back spaces around a special building may be permitted subject to the condition that the clearance of the proposed ramp from the property boundary / street alignment shall be minimum 1.5 m. and a clear motorable driveway of minimum 3.5 m. in width is available around the building.
PART-I
287
(18) The structures incidental to the main activities such as water closet / pump room, transformer room, transformer yard, electric room shall not be construed as individual block for the purpose of these regulations. However, these structures may be permitted in the prescribed set back space provided that they do not fall in the drive way and its height does not exceed 4.0 m. provided further that transformer and electrical rooms floor area does not exceed 15 sq.m. and W.C and Pump room per block does not exceed 6 sq.m.
(19) In cases of special building residential developments exceeding 100 Nos. in primary residential use zone, commercial and institutional uses not exceeding 10 percent of the floor area of the building at lower habitable floor levels, may be allowed (not for any industrial use) as incidental uses required for the occupants of the remaining residential developments within the premises.
(20) In areas where sewage system provided by the Public Health Division, Public Works Department / Local body concerned is not available and
(a) Where number of dwelling units exceeds 75 Nos. or 3750 sq.m. of commercial area (for this purpose 50 sq.m. is equated to one dwelling unit) sewage treatment plant shall be provided and maintained for the disposal of the sewage within the site itself with prior clearance from the Public Health Division, Public Works Department /Pollution Control Board as the case may be on location and design;
(b) Where number of dwelling units is less than 75 Nos. or 3750 sq.m. of commercial area, septic tank with up-flow filters shall be provided and maintained for the disposal of the sewage within the site itself.
(21) Any construction with roof over it in the terrace floor for A.C. Plant / structures shall be counted, as a floor and categorization of type of building shall be done accordingly.
(22) The space set apart for formation of a new road as per Master Plan or Detailed Development Plan or road widening / street alignment shall be transferred to the Authority or the Agency or the Local Body designated by the Authority through a registered Gift Deed before actual issuance of planning permission.
(25) Display Board:
(a) The details of the development for which planning permission issued, date of expiry of permit etc. shall be displayed in the format prescribed by the Authority on a board of size at least 60 cm. x 120 cm.
(b) The applicant shall pay a sum ₹ 10,000 as earnest money non interest bearing refundable deposit and the same should be utilized for the purpose of installing the prescribed size board on the site by the Planning Authority, in the event of the applicant not fulfilling the condition stated in (a) above.
(c) If the applicant fulfills the conditions (a) above, the deposit shall be refunded after production of the completion certificate.
[ PART-I]
(B) Group Development:
Definition: (1) Group development means accommodation for residential or commercial or combination of such activities housed in two or more blocks of buildings in a particular site irrespective of whether these structures are interconnected or not. Any inter link between the structures in terms of connecting corridors shall not be construed as making any two structures into one block. However, if these blocks are connected solidly at least for one third the width of any one block on the connecting side, then such blocks shall be construed as a single block.
(2) The minimum width of the public road on which the site abuts shall be 9.0 m. or the site should gain access from a passage of minimum width as prescribed below.
Explanation: The road width means average road width in front of the plot in question and for a few metres on either side for purposes of measurements to be taken in conjunction with the average width of that road in general. To cite examples and illustrates the principle:
(a) If the road over its general length is of 9.0 m. width, but because of some kinks in front of the plot one end is 8.8 m. and the other end is 9.2 m. is acceptable;
(b) If the general road is of width less than 9.0 m., but only widens opposite to or nearer to the plot is more than 9.0 m., is not acceptable.
(c) If the road is generally of 9.0m. width upto a considerable length on one side, but discontinues and narrows into a road of smaller width on the other side of the plot in question and the plot owner is willing to leave enough space for continuity of 9.0m. road in front of his plot, this will have to be checked and decided on case-by-case.
(d) If the general road width is less than 9.0m. and the plot owner merely agrees to leave enough space to have 9.0m. in front of his plot only, this is not acceptable.
(e) If the site does not directly abut a public road but gains access through a private exclusive passage or through part of the plot which can be treated as a passage from a public road of minimum width as prescribed above, the minimum width of such passage shall be as follows:
Sl.No.
Description
Minimum Width
1.
When it is intended to serve six dwellings or up to 600 sq.m. of commercial building and the length of the passage does not exceed 80.0 m.
3.6 m.
2.
When it is intended to serve up to 8 dwellings or up to 2,400 sq.m. of commercial building and the length of the passage does not exceed 100 m.
4.8 m.
3.
When it is intended to serve not more than 10 dwellings or up to 3000 sq.m. of commercial building and the length of passage does not exceed 120 m.
7.2 m.
4.
When it is intended to serve not more than 20 dwellings or up to 6000 sq.m. of commercial building and the length of passage does not exceed 240 m.
9.0 m.
5.
When it is intended to serve more than 20 dwellings or more than 6000 sq.m. of commercial building
10.0 m.
PART-I
289
(3) The extent of site, F.A.R., Set back etc. for Group Development shall be regulated according to the table below:-
Sl.No
Description
Continuous Building Area anywhere within Planning area
Other areas in Planning area
Economically Weaker Section
1
2
3
4
5
A
Minimum plot extent
300 sq.m.
600 sq.m.
300 sq.m.
B
Minimum Plot width / frontage
6.0 m.
12.0 m.
10.0 m.
C
Maximum Height
One and half times the width of the abutting road provided that the height may be exceeded to the extent of 1.0 m. for every 30 cm. by which the building is set back from the street or 15.00 m. whichever is less.
D
Maximum Coverage
60%
E
Maximum F.A.R.
150
F
Minimum Setbacks
Where Street Alignment / new road is prescribed in these regulations, it shall be from that street alignment / new road, In the case of others, it shall be from the property boundary.
(i)
Front Setback
4.5 m.
(ii)
Side Setback
1.50 m. on one side
3.5 m.
3.0 m.
(iii)(iv)
Rear Setback Spacing between blocks
1.5 m.6.0 m.
3.5 m.6.0 m.
3.0 m.3.0 m.
(4)
Structures permissible in the minimum prescribed Front set back, Side set back and Rear set back are given in the Clause 39 (4) chapter -III.
(5)
The minimum width of corridor shall be given in the clause No.38.(2) chapter -III
(6)
Parking spaces shall be provided within the site conforming to the regulations given in the Annexure- X.
(7)
Rainwater harvesting provisions as prescribed in the Annexure -VII shall be provided.
(8)
Special regulations for physically disabled stated in the Annexure -XVII shall be adhered to.
(9)
Solar energy capture provisions as prescribed in the Annexure -XVIII shall be provided where ever applicable.
(10)
The reservation of land for community recreational purposes such as park or play ground shall be as required in these regulations specified in Annexure - II.
(11)
Internal vehicular access way including passage if any within the site shall have a clear width of 7.2 m. and such vehicular access shall be available for every building block in the site within a distance of 50.0 m. Further, it shall be a clear open to sky and no projection of structure over it is permissible.
[ PART-I]
(17)
In cases of residential developments exceeding 100 dwelling units in primary residential use zone, commercial and institutional uses not exceeding 10 percent of the floor area of the building at lower habitable floor levels, may be allowed (not for any industrial use) as incidental uses required for the occupants of the remaining residential developments within the premises.
(18)
In areas where sewage system provided by the Public Health Division, Public Works Department / Local body concerned is not available and
(a)
Where number of dwelling units exceeds 75 Nos. or 3750 sq.m. of commercial area (for this purpose 50 sq.m. is equated to one dwelling unit) sewage treatment plant shall be provided and maintained for the disposal of the sewage within the site itself with prior clearance from the Public Health Division, P.W.D. / Pollution Control Board as the case may be on location and design;
(b)
Where number of dwelling units is less than 75 Nos. or 3750 sq.m. of commercial area, septic tank with up-flow filters shall be provided and maintained for the disposal of the sewage within the site itself.
(19)
Any construction with roof over it in the terrace floor for A.C. Plant / structures shall be counted, as a floor and categorization of type of building shall be done accordingly.
(20)
In the interest of the public for better circulation in the area and also to ensure that the proposed development does not block access to the properties around, in cases of large developments where link roads have to be provided for connectivity to the adjoining lands/areas, through the site applied for development, the Authority reserves the right to insist the applicant to set apart such road spaces within the site and the applicant shall hand over the same free of cost through a registered gift deed to the authority or Local body designated by it for declaring it as public road. In such cases set back from these roads to the buildings proposed shall be provided as prescribed in these regulations.
(21)
The space set apart for formation of a new road proposal in Master Plan / Detailed Development Plan or road widening / street alignment shall be transferred to the Authority or the Agency or the Local Body designated by the Authority through a registered Gift Deed before actual issuance of planning permission.
(22)
Basement Floor:
(a)
The height of basement floor shall not exceed 1.2 m. above the adjacent ground level and the headroom shall be minimum 2.4 m.
(b)
No basement shall be permitted on an individual plot unless it has a clear set back of 2 m. from the boundary line of the plot or the required setbacks which ever is more or in the minimum required set back required for the movement of fire fighting vehicles / equipments.
PART-I]
291
(12)
If the building is constructed on stilts and the stilt floor is to be used for parking, the minimum clear height of the floor (between the lower floor and the bottom of the beam) shall not exceed 2.4 m. and it shall not be enclosed for use as garages; if it is enclosed it shall be counted for F.A.R. and number of floors for the purpose of defining Group Development / Multistoreyed building.
(13)
In respect of building blocks exceeding 2 floors in height it shall be on stilts and stilt floor shall be reserved for parking.
(14)
If a Group Development contains more than one use and the allowability of the built space with reference to the abutting road width and exclusive passage width shall be decided based on the number of dwellings for the residential use and the equivalent floor area allowable for commercial and other uses.
(15)
Vehicular ramp in set back spaces around building blocks may be permitted subject to the condition that the clearance of the proposed ramp from the property boundary / street alignment shall be minimum 1.5 m. and a clear motorable driveway of minimum 3.5 m. in width is available around the building block.
(16)
The structures incidental to the main activities such as water closet / pump room, transformer room, transformer yard, electric room shall not be construed as individual block for the purpose of these regulations. However, these structures may be permitted in the prescribed set back space provided that they do not fall in the drive way and its height does not exceed 4.0 m. provided further that transformer and electrical rooms floor area does not exceed 15 sq.m. and W.C and Pump room per block does not exceed 6.0 sq.m.
(c)
In cases where second basement is proposed for parking and incidental uses, sufficient provision for lighting and ventilation and also for protection from fire to the satisfaction of Fire Service Department shall be made.
(d)
During the construction of the basement floor, it shall be sole responsibility of the planning permission holder to ensure that the building / structure in the adjoining sites are not weakened / damaged
(23)
Security Deposit:
The applicant shall deposit a sum at the rate of ₹50/- per sq.m. of floor area as a refundable non-interest earning security and earnest deposit. The deposit shall be refunded on completion of development as per the approved plan as certified by Planning Authority; if not, it would be forfeited.
(24)
Display Board:
(a)
The details of the development for which planning permission issued, date of expiry of permit etc. shall be displayed in the format prescribed by the Authority on a board of size at least 60 cm. x 120 cm.
(b)
The applicant shall pay a sum of ₹10,000/- (Rupees ten thousand only) as earnest money non interest bearing refundable deposit and same should be utilized for the purpose of installing the prescribed size board on the site by Planning Authority, in the event of the applicant not fulfilling the conditions stated in (a) above.
(c)
If the applicant fulfills the conditions (a) above, the deposit shall be refunded after production of the completion certificate.
(25)
Group development exceeding 50 dwelling units or where the extent of the site on which it is proposed exceeds 1 hectare it shall be designed and the plans signed by a qualified Architect
(26)
Notwithstanding anything stated above, Group developments for E.W.S. housing, may be approved subject to the conditions as may be stipulated by the Authority.