1. STRUCTURAL DESIGN :
For any building categorized under multistoreyed buildings / special buildings / group developments under the jurisdiction of these byelaws structural design / retrofitting shall only be carried out by a Registered Structural engineer. Proof checking of various designs / reports shall be carried out by competent authority as per Table-1 wherever applicable.
Generally, the structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall conform to the provisions of part-VI Structural Design Section -1 Loads, Section -2 Foundation, Section -3 Wood, Section -4 Masonry, Section -5 Concrete & Section -6 Steel of National Building Code of India (N.B.C.), taking into consideration the Indian Standards as given below:
For General Structural Safety:
| 1. | I.S.: 456:2000 | “Code of Practice for Plain and Reinforced Concrete”. |
| 2. | I.S.: 800-1984 | “Code of Practice for General Construction in Steel”. |
| 3. | I.S.: 801-1975 | “Code of Practice for Use of Cold Formal Light Gauge Steel Structural Members in General Building Construction”. |
| 4. | I.S.: 875(Part 2):1987 | “Design loads (other than earthquake) for buildings and structures Part 2 Imposed Loads”. |
| 5. | I.S.: 875(Part 3):1987 | “Design loads (other than earthquake) for buildings and structures Part 3 Wind Loads” |
| 6. | I.S.: 875(Part 4):1987 | “Design loads (other than earthquake) for buildings and structures Part 4 Snow Loads” |
| 7. | I.S.: 875(Part 5):1987 | “Design loads (other than earthquake) for buildings and structures Part 5 special loads and load combination” |
| 8. | I.S.:883:1966 | “Code of Practice for Design of Structural Timber in Building” |
| 9. | I.S.: 1904-1987 | “Code of Practice for Structural Safety of Buildings Foundation” |
| 10. | I.S.: 1905:1987 | “Code of Practice for Structural Safety of Buildings: Masonry Walls” |
| 11. | I.S.: 2911 (Part 1):Section 1: 1979 | “Code of Practice for Design and Construction of Pile Foundation Section 1”. |
| Part-I | Section 2 Based Cast-in-situ-Piles | |
| Part-I | Section 3 Driven Precast Concrete Piles | |
| Part 1: | Section 4 Based Precast Concrete Piles | |
| Part 2: | Timber Piles | |
| Part 3: | Under Reamed Piles | |
| Part 4: | Load Test on Piles | |
For Cyclone/Wind Storm Protection:
(12) I.S. 875 (3)-1987 "Code of Practice for Design Loads (other than Earthquake) for Buildings and Structures, Part 3, Wind Loads".
(13) Guidelines (Based on IS 875 (3)-1987) for improving the Cyclonic Resistance of Low rise houses and other buildings.
For Earthquake Protection:
(14) I.S.: 1893-2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)".
(15) I.S.: 13920-1993 "Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces - Code of Practice".
[ PART-I]
(16) I.S.: 4326-1993 "Earthquake Resistant Design and Construction of Buildings - Code of Practice (Second Revision)".
(17) I.S.: 13828-1993 "Improving Earthquake Resistance of Low Strength Masonry Buildings - Guidelines".
(18) I.S.: 13827-1993 "Improving Earthquake Resistance of Earthen Buildings - Guidelines".
(19) I.S.: 13935-1993 "Repair and Seismic Strengthening of Buildings - Guidelines".
For Protection of Landslide Hazard:
(20) I.S. 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part 1 Selection of type of wall.
(21) I.S. 14458 (Part 2): 1997 Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast walls.
(22) I.S. 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3 Construction of dry stone walls.
(23) I.S. 14496 (Part 2): 1998 Guidelines for preparation of landslide - Hazard zonation maps in mountainous terrains: Part 2, Macro-zonation.
Note: Whenever an Indian Standard including those referred in the National Building Code or the National Building Code is referred, the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code.
2. STRUCTURAL DESIGN BASIS REPORT (SDBR)
In compliance of the design with the above Indian Standard, the Structural Engineer on Record will submit a structural design basis report (SDBR) in the Proforma attached herewith covering the essential safety requirements specified in the Standard.
(i) The "Structural Design Basis Report (SDBR)" consists of four parts (Form No.12)
Part - 1 General Information / Data
Part - 2 Load Bearing Masonry Buildings
Part - 3 Reinforced Concrete Buildings
Part - 4 Steel Buildings
(ii) Drawings and Documents to be submitted for approval of Planning Authority shall include SDBR as detailed below:
Part - 1 Completed
Part - 2 (if applicable) - Completed
Part - 3 (if applicable) - undertaking that completed Part 3 will be submitted before commencement of construction
Part - 4 (if applicable) - undertaking that completed Part 4 will be submitted before commencement of construction.
(iii) SDBR as detailed below shall be submitted to the Planning Authority as soon as design of foundation is completed, but not later than one month prior to commencement of construction.
Part - 1 Completed
Part - 2 Part - 3 Part - 4} (if applicable) Completed.