27.1 Scope
These regulations are applicable to all buildings and facilities used by the public including Hospitals, Clinic, Educational Institutions of all types, Government Buildings, etc. It does not apply to private & public residences.
27.2 Access Path / Walk Way
Access path from the entry and surface parking to Building entrance shall be minimum of 1800mm wide having even surface without any steps. Slope if any, shall not have gradient greater than 5%. Selection of floor material shall be made suitably to attract or to guide visually impaired persons. (hereinafter referred to as "guiding floor material" as explained in Regulation No.27.16”). Finishes shall have a non-slip surface with a texture traversable by a wheel chair. Curbs wherever provided should blend to a common level.
27.3 Parking
For parking of vehicles, the following provisions shall be made:
(a) Parking should be within 30.0 m of the main entrance of the building.
(b) The width of parking bay shall be minimum 3.60 m. Overall minimum dimensions shall be 3.60 m x 4.80 m.
(c) The parking should have the international signage (as explained in Regulation No.17) painted on the ground and also on a sign post/board put near it.
(d) Required number of reserved parking spaces shall be as below
| SPACESIN PARKING LOT | REQUIREDNO. OFRESERVED PARKING SPACE |
|---|---|
| 1-25 | 1 |
| 26-50 | 2 |
| 51-75 | 3 |
| 76-100 | 4 |
| 101 and above | 5 plus 1 per 25 above100 |
27. 4 APROACH
Every building or block should have at least one entrance accessible to the handicapped and shall be indicated by proper signage. This entrance shall be approached through a ramp together with the stepped entry.
27.5 Ramp
(a) Surfaces of ramp and landing shall be finished with non-slip material to enter the building.
(b) Minimum width of ramp shall be 1200 mm.
(c) Maximum gradient of 1:12.
(d) Inclined stretch of a ramp shall not exceed 9.0 meters having handrails at a height of 850 mm - 900 mm on both sides extending 300 mm beyond top and bottom of the ramp.
(e) Minimum gap from the adjacent wall to the handrail shall be 50 mm.
27.6 Steps and Stairs
(a) Uniform risers : 150 mm and treads : 300 mm.
(b) The steps should have an unobstructed width of at least 1200 mm.
(c) The landing should be at least 1200 mm long, clear of any door swing
(d) Stair edges should have bright contrasting colours : 50 mm minimum (e) The maximum height of flight between landing to be 1200 mm.
(f) Stairs should have continuous handrails on both sides including the wall (if any) at a height of 850 mm - 900 mm.
(g) Nosing to be avoided.
27.7 Entrance Landing
Entrance landing shall be provided adjacent to ramp with the minimum dimension of 1800 mm x 2000 mm. The entrance landing that adjoin the top end of a slope shall be provided with guiding floor material. Landing shall have a non-slip surface with a textured finish. Curbs wherever provided should blend to a common level.
27.8 Corridors
(a) Should have an unobstructed minimum width of 1500 mm
(b) All protruding objects more than 100 mm from the wall to be placed either in a niche or above 2100 mm from the floor
(c) Guiding floor material shall be provided
27.9 Doors
(a) Minimum clear opening of the door shall be 900 mm and it shall not be provided with a step that obstructs the passage of a wheel chair user.
(b) Threshold shall not be more than 12 mm
(c) Doors should not open into corridors
(d) A distance of 450 mm should be provided beyond the leading edge of the door
(e) Should be fitted with lever action locks and D-handles of circular section. Knob handles should be avoided.
(f) Kick places are recommended 300 mm from bottom
27.10 Lifts
(a) Wherever lift is required as per bye-laws, provision of at least one lift shall be made for the wheel chair user with the following minimum cage dimensions of
Clear internal depth : 1100 mm Clear
internal width : 2000 mm
Clear door width : 900 mm
(b) A hand rail not less than 600 mm long at 1000 mm above floor level shall be fixed adjacent to the control panel.
(c) The lift lobby shall be of an inside measurement of 1800 mm x 1800 mm or more.
(d) The time of an automatically closing door should be minimum 5 seconds and the closing speed should not exceed 0.25 m/sec.
(e) The interior of the cage shall be provided with a device that audibly indicates the floor the cage has reached and indicates that the door of the cage is either open or closed.
27.11 Toilets
One special W.C in a set of toilet shall be provided for the use of handicapped persons with essential provision of wash basin near the entrance with proper signage.
(a) The minimum size shall be 1500 mm x 1800 mm.
(b) Minimum clear opening of the door shall be 900 mm and the door shall be swing out.
(c) Suitable arrangement of vertical / horizontal hand rails with 50 mm clearance from wall shall be made in the toilet.
(d) The top of the W.C seat shall be 500 mm from the floor. e) Should have slip resistant flooring.
(f) Wash basin shall have a knee space of at least 760 mm wide by 200 mm deep by 650 mm - 680 mm height with lever type handle.
(g) Shall be provided with a switch that activates an emergency alarm.
27.12 Drinking Water
Suitable provision of drinking water shall be made for the handicapped near the special toilet provided for them.
27.13 Service and Information Counters
Public dealing counters and writing surfaces should not be more than 800 mm from the floor, with a minimum clear knee space of 650 mm - 680 mm height and 280 mm - 300 mm deep.
27.14 Relaxation
In the buildings meant for the predominant use of the children, it will be necessary to suitably alter the height of the handrails and other fittings & fixtures etc.
27.15 Controls
Window lever and electrical control should be maximum in the range of 450 mm to 1200 mm from the floor.
27.16 Explanatory Notes
1. GUIDING / WARNING FLOOR MATERIAL
The floor materials to guide or to warn the visually impaired persons with a change of colour or material with conspicuously different texture and easily distinguishable from the rest of the surrounding floor materials is called guiding or warning floor materials. The material with different texture gives audible signals with sensory warning when a person moves on this surface with walking stick. The guiding / warning floor material is meant to give the directional effect or warn a person at critical places. This floor material shall be provided in the following areas:-
(a) The access path to the building and to the parking area.
(b) The landing lobby towards the information board, reception, lifts, stair-cases and toilets
( c ) Immediately at the beginning / end of walkway where there is a vehicular traffic.
(d) At the location abruptly changing in level or ramp.
(e) Immediately in front of an entrance / exit and the landing.
2. HANDRAILS
(a) Should be circular in section with a diameter of 40 mm - 45 mm.
(b) At least 45 mm clear of the surface to which they are attached.
(c) At the height of 850 mm - 900 mm from the floor
(d) Should extend by at least 300 mm beyond the head and foot of the flight and ramp and should be grouted in the ground.
(e) Should be of contrasting colour.
3. PROPER SIGNAGE
Appropriate identification of specific facilities within a building for the handicapped persons should be done with proper signage. Visually impaired persons make use of other senses such as hearing and touch to compensate for the lack of vision. Whereas visual signals benefit those with hearing disabilities.
There should be directional signs guiding handicapped people to the various facilities. Signs should be mounted between 1400 mm and 1600 mm from the floor level and should be designed and located so that they are easily legible by using suitable letter size (not less than 20 mm high). For visually impaired persons information board in Braille should be installed on the wall at a suitable height and it should be possible to approach them closely. To ensure safe walking there
should not be any protruding sign which creates obstruction in walking. Public Address System may also be provided in busy public areas.
The symbols /information should be in contrasting colour. and properly illuminated because people with limited vision may be able to differentiate amongst primary colours. International symbol mark for wheel chair as shown below be installed at the lift, toilet, staircase, parking areas etc., that have been provided for the handicapped.
4. WHEEL CHAIR
Chair used by disabled people for mobility. The standard size of wheel chair shall be taken as 1050 mm x 750 mm.