26.1 Scope
These regulations shall be applicable to development of schemes for socially and economically backward class of people for economically weaker section of the society and for low cost housing only undertaken by public agencies, co-operative societies Government or Semi Government bodies, Registered Developers.
26.2 Planning
The type of development for housing for socially and economically backward class of people and for low cost housing, block development as group housing.
-
The maximum permissible density in Dwelling shall be 225 dwelling per hector .
-
The minimum and the maximum plot size shall be between 18 sq.m. and 40. sq.m. respectively with built up area not exceeding 70% of the plot area leaving front as well as rear margin of 1.50 m.
-
The minimum frontage of plot shall be 3.00 m in width.
-
At every 20 such continuous plots 2.00 m wide space open to sky shall be provided.
-
The maximum numbers of stories in a building construction on the plot shall be ground plus one upper storey only. Parking on stilts or hollow plinth shall be allowed.
-
Common plot at the rate of 10% percent of the area of the plot/ land developed shall be provided for open space/ community open space which shall be exclusive of approach roads , path ways, or margins .
26.3 General Building Requirements
-
The minimum height of the plinth shall be 30.00 cm from the top surface of approach road or path way.
-
The maximum floor space index permissible shall be 1.8. (No paid F.S.I. shall be available)
-
(a) The size of living room , bed room shall not be less than 8 sq.m. with minimum width of 2.40 m.
(b) (i)Size of independent Bath-room and W.C. shall be 0.90 sq.m. with minimum width of 0.90 m each.
(ii) Size of combined bath room and W.C. shall be 1.80 sq.m. with minimum width of 1.00 m.
- (i) The minimum height of room shall be as under:
Living room : 2.40 m
Kitchen room : 2.40 m
Bath /W.C. : 2.10 m
Corridor : 2.10 m
(ii) In case of the slopping roof the average height of the roof shall be 2.10 m and the minimum height of the eaves shall be 2.40 m.
(iii) The minimum slopes of the slopping roof ,shall be 300 for G.I sheets , asbestos sheets or tiled roof while for R.C.C slopping roof , the minimum slop shall be 120.
- The opening through windows , ventilators and other opening for light and ventilation shall be as under:
(i) One tenth of the room floor area.
(ii) For W.C. and bath not less than 0.20 sq.m.
The minimum width of stair case shall be 0.75 m. The maximum height of the riser shall be 20.00 cm. The minimum width of the tread shall be 22.50 cm The minimum clear head roof of the stair case shall be 2.10 m.
(iii) There shall be one staircase for every 12 (twelve) dwelling units or part thereof.
26.3 Roads and Path Ways
1.The area under the roads and pathways in such housing project shall normally not exceed 20% of the total area of the project.
-
Access to the dwelling units where motorised vehicles are not normally expected shall be by means of paved foot paths with right of way of 6.00 m and pathways of 2.00 m only . The right of way shall be adequate to allow for plying of emergency vehicles and also for side drains and plantation.
-
Where motorable access ways are not provided and pedestrian path ways are provided the minimum width of such path way shall be 4.00 m, which shall not exceed 50.00 m in length.
26.4 Minimum Required: Accommodation
-
The minimum accommodation provided in every dwelling unit shall be one living room and a W.C. where there is a drainage system , the agency developing the area shall install and maintain the internal drainage system. where there is no drainage system the individual soak-pit shall be provided as per provision of National Building Code.
-
The loft if provided in the room shall not cover more than 30 % of the floor area of the room.
26.5 Structural Requirements
-
Load bearing walls of the building shall be of Brick stone or pre cast block in any mortar. in the case of R.C.C framed structure or wooden framed structure filler walls may be of suitable local materials.
-
Roof of the building shall be of galvanized iron sheets, asbestos sheet , tiles roof or R.C.C. roof .in the case of upper storied buildings middle floor shall be of wooden or R.C.C. and rest as per choice.
-
Doors and windows of building shall be of any material.
-
Rest of the work of building shall be as per locally available resources and as per choice.
-
For structural safety and services Regulations 19 a shall be applicable.